THIS FIELD NOTICE IS PROVIDED ON AN "AS IS" BASIS AND DOES NOT IMPLY ANY KIND OF GUARANTEE OR WARRANTY, INCLUDING THE WARRANTY OF MERCHANTABILITY. YOUR USE OF THE INFORMATION ON THE FIELD NOTICE OR MATERIALS LINKED FROM THE FIELD NOTICE IS AT YOUR OWN RISK. CISCO RESERVES THE RIGHT TO CHANGE OR UPDATE THIS FIELD NOTICE AT ANY TIME.
Affected Product Name | Description | Comments |
---|---|---|
HX-HD12TB10K12G | 1.2 TB 12G SAS 10K RPM SFF HDD | |
HX-HD12TB10K12G= | 1.2 TB 12G SAS 10K RPM SFF HDD | |
HX-M2-240GB | 240GB SATA M.2 | |
HX-M2-240GB= | 240GB SATA M.2 | |
HX-SD240GBE1NK9 | ^240GB Enterprise Value SSD (SATA) (1X FWPD, SED) | |
HX-SD240GBE1NK9= | ^240GB Enterprise Value SSD (SATA) (1X FWPD, SED) | |
HX-SD240GBM1K9 | ^240GB Enterprise Value SSD (SATA) (1X FWPD, SED) | |
HX-SD240GBM1K9= | ^240GB Enterprise Value SSD (SATA) (1X FWPD, SED) | |
HX-SD38TBE1NK9 | ^3.8TB Enterprise Value SSD (SATA) (1X FWPD, SED) | |
HX-SD38TBE1NK9= | ^3.8TB Enterprise Value SSD (SATA) (1X FWPD, SED) | |
HX-SD38TBM1K9 | ^3.8TB Enterprise Value SSD (SATA) (1X FWPD, SED) | |
HX-SD38TBM1K9= | ^3.8TB Enterprise Value SSD (SATA) (1X FWPD, SED) | |
HX-SD960GBE1NK9 | ^960GB Enterprise value SATA SSD (1X FWPD, SED) | |
HX-SD960GBE1NK9= | ^960GB Enterprise value SATA SSD (1X FWPD, SED) | |
HX-SD960GBM1K9 | 960GB Enterprise Value SSD (SATA) (1X FWPD, SED) | |
HX-SD960GBM1K9= | 960GB Enterprise Value SSD (SATA) (1X FWPD, SED) | |
UCS-HD12TB10K12G | 1.2 TB 12G SAS 10K RPM SFF HDD | |
UCS-HD12TB10K12G= | 1.2 TB 12G SAS 10K RPM SFF HDD | |
UCS-M2-240GB | 240GB M.2 SATA Micron G1 SSD | Part Alternate |
UCS-M2-240GB= | 240GB M.2 SATA Micron G1 SSD | Part Alternate |
Defect ID | Headline |
CSCwh94241 | HX cluster down after HX-HD12TB10K12G drives of different sector size installed |
CSCvm66552 | Multiple simultaneous 3.8TB SED SSD drive failures may cause the HX cluster to go offline |
CSCvk17250 | Cluster instability when disks of different sector size placed in HX node |
CSCvj66157 | SED drive failure may cause the UCS/HX cluster to go down |
A drive firmware issue on select Self-Encrypting Drives (SEDs) might cause an operational issue for some HyperFlex clusters.
An increased rate of blocked drives might occur, which requires frequent drive replacements and in some instances a potential for a HyperFlex cluster outage.
A second drive issue can occur during drive replacement or drive addition (both SED or non-SED). If the sector size of the existing drive differs from that of the replacement drive, there is a potential for a HyperFlex cluster outage.
All existing clusters running HXDP version below 3.5.2b (including older HX 2.x and 3.0) should be upgraded to the latest 3.5 release available on cisco.com before any disks are added/replaced or cluster expansion.
An operational bug in the drive firmware might be triggered when the drive is subjected to a specific workload, which could result in uncorrectable drive-level errors. Software upgrades are recommended in order to mitigate potential risks associated with uncorrectable errors. A couple of newer issues have also been addressed where data that is read in one location can affect data stored in an adjacent location and during drive replacement or addition there is a potential block size mismatch of drive sector size which leads to the cluster outage.
HyperFlex blocks the drive when the involved errors are encountered. The blocked drive state is when a disk is not utilized by the cluster due to either a software error or an I/O error. This could be a transitional state while the cluster attempts to repair the disk, if the disk is still available, before the state transitions to "repairing". After repeated I/O errors the drive might be permanently blocked, which could trigger frequent drive replacements. While the HyperFlex HX Data Platform (HXDP) software protects against drive failures, there is a potential for the cluster to fail after multiple, simultaneous drive failures.
In order to handle the errors, HXDP software puts the drive in a blocked state. When there are several drive errors, the drive is permanently blocked as shown in the How To Identify Affected Products section. Blocked drives appear as shown in the How To Identify Affected Products section.
Note: All clusters that have the affected parts need to be upgraded as soon as possible and the upgrade recommendation is not limited to clusters that show this symptom.
HyperFlex blocks the drive when the involved errors are encountered. The "blocked" drive state is when a disk is not utilized by the cluster due to either a software error or an I/O error. This could be a transitional state while the cluster attempts to repair the disk, if the disk is still available, before the state transitions to "repairing". After repeated I/O errors the drive might be permanently blocked, which could trigger frequent drive replacements. While the HXDP software protects against drive failures, there is a potential for the cluster to fail after multiple, simultaneous drive failures.
The action required for HyperFlex nodes is listed in this table.
Configuration | Action Required |
---|---|
Systems with only HX-M2-240GB boot drive (no SED in system) | Perform a combined upgrade - HXDP to Version 3.5(2b) or later*, and Unified Computing System Manager (UCS Manager) to Version 4.0(1c) or later. Note: Do not upgrade UCS Manager only. |
Clusters not created | Create the cluster with UCS Manager Version 4.0(1c) or later*, and HXDP Version 3.5(2b) or later*. |
Clusters created (with SEDs or disks that may have different sector sizes) |
|
* This is the minimum upgrade version. The recommended version to be used is listed in Recommended Cisco HyperFlex HX Data Platform Software Releases - for Cisco HyperFlex HX-Series Systems.
See Cisco HyperFlex Systems Upgrade Guides for instructions on how to upgrade your system.
UCS Manager software images are available at UCS Infrastructure and UCS Manager Software Release 4.0(1C).
HyperFlex software images are available at HyperFlex HX Data Platform Release 3.5(2i).
Cisco recommends that you enable autosupport in order to enhance the supportability of HyperFlex clusters.
All HyperFlex releases posted are supported, however the recommended release is designated with a "*" next to the release name on the Software Download page.
HyperFlex Systems
The Products Affected section lists the systems with the affected drive Product IDs.
Note: The upgrade and the remediation process post upgrade is required irrespective of whether or not the system currently shows blocked drives.
Blocked drives can be seen in the drive inventory on the HyperFlex Connect user interface as follows:
Blocked drives also appear in the System Overview tab. Click on any slot with a red circle as shown in this example.
Version | Description | Section | Date |
2.0 | Add additional PIDs and generalize to impacting all drives with sector size differences | Products Affected, Description, Workaround/Solution | 2024-FEB-23 |
1.9 | Updated Terminology | — | 2020-JUL-20 |
1.8 | Updated the Defect Information, Problem Description, Background, Problem Symptom, and Workaround/Solution Sections | — | 2020-APR-02 |
1.7 | Updated the Workaround/Solution Section | — | 2019-MAR-25 |
1.6 | Updated the Workaround/Solution and How to Identify Affected Products Sections | — | 2019-FEB-11 |
1.5 | Updated the Workaround/Solution Section | — | 2019-JAN-04 |
1.4 | Updated the Background, Workaround/Solution, and How to Identify Affected Products Sections | — | 2018-DEC-04 |
1.3 | Updated the Defect Information, Background, and Workaround/Solution Sections for HX Release 3.0(1i) | — | 2018-NOV-28 |
1.2 | Updated the Product Hierarchy Metatags | — | 2018-OCT-18 |
1.1 | Updated for HyperFlex Content | — | 2018-AUG-16 |
1.0 | Initial Release | — | 2018-JUN-28 |
For further assistance or for more information about this field notice, contact the Cisco Technical Assistance Center (TAC) using one of the following methods:
To receive email updates about Field Notices (reliability and safety issues), Security Advisories (network security issues), and end-of-life announcements for specific Cisco products, set up a profile in My Notifications.