The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product. Learn more about how Cisco is using Inclusive Language.
For translations of the warnings that appear in this document, see the Regulatory Compliance and Safety Information document for your router on Cisco.com:
When using the online publications, see the documents that match the Cisco system software version running on the WPAN module.
Features
The WPAN module provides IEEE 802.15.4 g/e-compliant, and highly secure wireless connectivity for the Cisco 1000 Series Connected Grid Routers to enable Field Area Network (FAN) applications.
The module is ideal for multi-hop mesh networks and long-reach solutions and helps enable a high ratio of endpoints to the Field Area Router (FAR). The WPAN module provides the following functionality:
Dynamic network discovery and self-healing network capabilities based on IEEE 802.15.4 g/e
A subset of the frequency range can be selected according to the regulations of your country. See Configuration
Advanced Encryption Standard (AES) 128-bit encryption
IEEE 802.1x networking protocol
WPAN module health monitoring
WPAN module reset and reprogram functionality
WPAN module interface statistics and status
Hardware Overview
The WPAN module hardware contains a Cortex-M3, microcontroller, Texas Instruments CC1101 RF Transceiver operating in the 900 MHz ISM band, Semtech SX1781 PLL Frequency Synthesizer, and RF Micro Devices RF6559 front-end module.
The WPAN module can be installed into any slot in CGR 1000 Series routers.
Figure 2 shows the front panel of the WPAN module.
Figure 2 Front Panel of the Cisco Connected Grid WPAN Module
LED
Table 1 lists the LED indicators and describes the behavior. The LED provides a visual indicator of the available services.
Table 1 LED Indicator
LED Name
Color
Description
Status
Green
Indicates the RF status:
Off: Module is not powered
On: System is functional - RF mesh interface is up (if installed)
Blinking: Hardware is functional - RF mesh interface is up (if installed)
Supported Cisco Antenna
The antenna is connected to the QMA, panel-mount, 50-ohm connector located on the faceplate of the WPAN module.
For more information about antennas, including installation steps, see the Cisco Connected Grid 1240 Router Installation Guide.
Table 2 lists the Cisco antennas supported for use with the WPAN module and the Cisco Connected Grid 1120 Router.
Table 2 CGR 1240 Supported Antennas and Cables for use with the WPAN Module
Description
Outdoor Cable
Antennas
WPAN module
10.5’or 17.5’ cable through conduit
Single cable passes through conduit from inside to outside building.
900 MHz, 3G, 806 to 960 MHz, 1710 to 2700 MHz, monopole antenna, chassis mounted, omni-directional, includes non-integrated co-axial cable. No cable (option class).
ANT-MP-INT-OUT-M
900 MHz ISM band, outdoor, omnidirectional stick, 5 dBi gain, N(f), qty 1
ANT-WPAN-OM-OUT-N
Cisco Supported Cables
Table 3 lists the external cable options and internal cable/adapter available from Cisco for use with the WPAN module.
Table 3 Cisco External and Internal Cables for WPAN Module
Outdoor Cable Options
Indoor Cable/Adapter
Antennas
RA-N(m) to N(m), LMR-400-DB, 20’, qty 1
CAB-L400-20-N-N
RA-N(m)-N(m), LMR-600-DB, 30’, qty 1
CAB-L600-30-N-N
RA-QMA(m) to N(m), LMR-240-FR, 10’, qty 1
CAB-L240-10-Q-N
Lightning arrestor, N(f)-N(f), qty 1
CGR-LA-NF-NF
900 MHz ISM band, omnidirectional stick, 5 dBi gain, N(f), qty 1
ANT-WPAN-OM-OUT-N
None
RA-QMA(m) to RA-MCX (m), LMR-100, 10.5”, qty 2
CAB-L100-10-Q-M
900 MHz, 3G, 806 to 960 MHz, 1710 to 2700 MHz, monopole antenna, chassis mounted, omnidirectional, qty 2
ANT-MP-INT-OUT-M
Interfaces
The WPAN module includes the following physical interfaces to the host:
Single RF Transceiver —supports IEEE 802.15.4g in the 902-to-928 MHz ISM. The RF transceiver is used to provide mesh networking connectivity.
Single Serial UART —used to communicate with the Cisco Connected Grid 1240 Router host processor via the onboard FPGA I/O module, providing framing control and buffering for UART data communications.
GPIO —control and data communications
Configuration
The configuration parameters are set by the Connected Grid Network Management System (CG-NMS), through a series of CLI commands.
Statistics on network traffic is also retrieved from the interface through the RF port manager, through the use of the CLI.
Table 5 lists the default frequencies for each channel.
Table 5 List of Default Frequencies for each Channel
Channel #
Channel f. (MHz)
Channel #
Channel f. (MHz)
Channel #
Channel f. (MHz)
Channel #
Channel f. (MHz)
1
902.250
14
908.750
27
915.250
40
921.750
2
902.750
15
909.250
28
915.750
41
922.250
3
903.250
16
909.750
29
916.250
42
922.750
4
903.750
17
910.250
30
916.750
43
923.250
5
904.250
18
910.750
31
917.250
44
923.750
6
904.750
19
911.250
32
917.750
45
924.250
7
905.250
20
911.750
33
918.250
46
924.750
8
905.750
21
912.250
34
918.750
47
925.250
9
906.250
22
912.750
35
919.250
48
925.750
10
906.750
23
913.250
36
919.750
49
926.250
11
907.250
24
913.750
37
920.250
50
926.750
12
907.750
25
914.250
38
920.750
51
927.250
13
908.250
26
914.750
39
921.250
52
927.750
Environmental Specifications
Following are the operating temperature range for the routers:
Connected Grid 1120 Router: -40 to 60° C (-40° F to 140° F)
Connected Grid 1240 Router: -40 to 70° C (-31° F to 158° F)
Table 6 lists the environmental specifications for the Connected Grid WPAN Module.
Table 6 WPAN Module Environmental Specifications
Environmental—Operational
Specifications
Temperature—operational
-40 to 70-degrees C (-40 to 158-degrees F)
Altitude
Up to 1500 meters
Humidity
RH95% noncondensing
Vibration
1.0 g from 1.0 to 150 Hz
Shock
30 G half sine 6 ms and 11 ms
Seismic
GR63-Core, Zone 4
Power Specifications
The Connected Grid WPAN Module has a 12V power rail and 3.3V standby power provided by the host system.
Installing and Removing the Module
Before installing the WPAN module, verify the following guidelines have been met:
Clearance to the I/O side view is such that the LED can be read
Airflow around the WPAN module and through the vents is unrestricted
Temperature around the unit does not exceed 140-degrees F (60-degrees C). If the WPAN module is installed in a closed or multi-rack assembly, the temperature around it might be higher than normal room temperature.
Relative humidity around the WPAN module does not exceed 95% (non-condensing)
Altitude at the installation site is not higher than 10,000 feet
After replacing or installing a module in the router, you must update the label (on the router exterior) that lists the module types contained in the router. The label must list the FCC ID number and the IC Certification number for each module installed in the router.
Note You must use RFLAN module software for all firmware upgrades. You cannot upgrade the RFLAN firmware with CG-Mesh module firmware code. RFLAN and CG-mesh WPAN firmware are incompatible.
Installation Warning Statements
This section includes the basic installation warning statements. Translations of these warning statements appear in the Regulatory Compliance and Safety Information for Cisco Connected Grid Router 1000 Series Routers documents.
Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement 1030
Warning To prevent the system from overheating, do not operate it in an area that exceeds the maximum recommended ambient temperature of 140°F (60°C). Statement 1047
Warning To prevent airflow restriction, allow clearance around the ventilation openings to be at least: 1.75 in. (4.4 cm). Statement 1076
Installing the WPAN Module
Follow these steps to install the module into an available slot in the Cisco Connected Grid 1120 Router or the Cisco Connected Grid 1240 Router:
Caution
The module can NOT be hot swapped—to install the module, you must first power down the module.
Step 1 Before you install (or remove) the Connected Grid WPAN Module from the host router, you must power down the router as described in the Hardware Installation Guide of your router.
Step 2 Insert the WPAN module into the slot.
Step 3 Using a screwdriver, secure the two captive screws into place.
Removing the WPAN Module
Follow these steps to remove the WPAN module from a slot in the Cisco Connected Grid 1120 Router, or the Cisco Connected Grid 1240 Router:
Caution
The module can NOT be hot swapped—to install the module, you must first power down the module.
Step 1 Using a screwdriver, loosen the two captive screws on the Connected Grid WPAN Module.
Step 2 Gently pull the WPAN module out of the slot.
Regulatory and Compliance Information
For regulatory compliance and safety information for the WPAN module, refer to the Connected Grid Router 2000 Series Regulatory Compliance and Safety Information document:
Note Before configuring the CGR1000 with the cell relay feature, the WPAN module must be install in the router.
Prerequisites
The Cisco 1000 Series Connected Grid Routers have the following:
Two slots for WAN/LAN interface cards
An 8-port switch, out of which two are combo ports (ports 7 and 8)
One console port
One auxiliary port
Two serial ports
Connecting to the console port of the Cisco Connected Grid 1240 Router displays the loading sequence. Once the router has completed the boot process, the login prompt displays.
Note The system takes up to three minutes to come up after you initially login and start configuring the router. Please wait for the prompt before continuing and running CLI commands.
Refer to the Cisco Connected Grid 1240 Router Configuration Guide for details on how to bring up and log into the router.
Sample Router Configuration
The following is a sample configuration:
router# show running-config
!Command: show running-config
!Time: Tue Oct 4 15:23:02 2011
version 5.2(1)
logging level feature-mgr 0
hostname Altamont37
vdc wireless-far id 1
limit-resource vlan minimum 16 maximum 4094
limit-resource vrf minimum 2 maximum 4096
limit-resource u4route-mem minimum 9 maximum 9
limit-resource u6route-mem minimum 24 maximum 24
limit-resource m4route-mem minimum 58 maximum 58
limit-resource m6route-mem minimum 8 maximum 8
feature telnet
feature crypto ike
crypto ike domain ipsec
policy 10
authentication pre-share
group 5
key Cisco123 address 11.0.0.1
key Cisco123 address 192.10.0.1
key Cisco123 address 192.168.168.1
feature scheduler
feature ospf
feature netflow
feature dhcp
feature tunnel
feature crypto ipsec virtual-tunnel
feature c1222r <-- Cell Relay
logging level ntp 7
logging level evmc 7
logging level evms 7
logging level vshd 7
logging level wifipm 2
logging level netstack 3
username adminbackup password 5 ! role network-operator
username admin password 5 $1$clxfU5Ae$auC5BarZetpQMhU4gjA5a. role network-admin
no password strength-check
ip domain-lookup
copp profile strict
snmp-server user admin network-admin auth md5 0xa4495f08940116511391f04d149fc878
The Cisco Support and Documentation website provides online resources to download documentation, software, and tools. Use these resources to install and configure the software and to troubleshoot and resolve technical issues with Cisco products and technologies. Access to most tools on the Cisco Support and Documentation website requires a Cisco.com user ID and password.
Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL: www.cisco.com/go/trademarks. Third-party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (1110R)
Any Internet Protocol (IP) addresses and phone numbers used in this document are not intended to be actual addresses and phone numbers. Any examples, command display output, network topology diagrams, and other figures included in the document are shown for illustrative purposes only. Any use of actual IP addresses or phone numbers in illustrative content is unintentional and coincidental.