This chapter lists the system messages by facility. Within each facility, the messages are listed by severity levels 0 to 7: 0 is the highest severity level, and 7 is the lowest severity level. Each message is followed by an explanation and a recommended action.
This section contains the AAA messages.
Error Message AAA-1-AAA_SESSION_LIMIT_REJECT: aaa request rejected as maximum aaa sessions are in progress
Explanation Aaa request rejected as the limit for maximum concurrent aaa sessions is reached
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message AAA-3-AAA_NVRAMFAILURE: nvram failure
Explanation Nvram can not be read/written to. Hence accounting log can not be stored there
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message AAA-6-AAA_ACCOUNTING_MESSAGE: [chars]
Explanation Accounting Message
Recommended Action No action is required.
This section contains the ACLLOG messages.
Error Message ACLLOG-4-ACLLOG_MAXFLOW_REACHED: [chars]
Explanation Max flow reached in current interval: [chars]
Recommended Action No action is required.
Error Message ACLLOG-4-ACLLOG_THRESHOLD: [chars]
Explanation Threshold Reached for Flow: [chars]
Recommended Action No action is required.
Error Message ACLLOG-6-ACLLOG_FLOW_INTERVAL: [chars]
Explanation Flow info in current alert interval: [chars]
Recommended Action No action is required.
Error Message ACLLOG-6-ACLLOG_NEW_FLOW: [chars]
Explanation New Acllog Flow: [chars]
Recommended Action No action is required.
This section contains the ACLMGR messages.
Error Message ACLMGR-2-PSS_ERROR: [chars]: PSS ret. val=[dec]
Explanation The ACLMGR service encountered error while operating on a persistent storage database.
Recommended Action No action is required.
Error Message ACLMGR-3-MTSERROR: [chars]
Explanation ACLMGR Service encountered an MTS error. [chars] specifies the context where the error occured.
Recommended Action No action is required.
This section contains the ACLQOS messages.
Error Message ACLQOS-SLOT#-4-ACLQOS_ATOMIC_ERR: [chars]
Explanation Tcam will be overused, please turn off atomic update
Recommended Action No DDTS.
This section contains the ACLTCAM messages.
Error Message ACLTCAM-6-ACL_TCAM_STATUS: Status: [chars].
Explanation ACLTCAM status is reported as: [chars].
Recommended Action No action is required.
This section contains the ACL messages.
Error Message ACL-6-ACL_DIAG_EVENT_STATUS: [chars] [hex].
Explanation ACL system health management event status is reported as [chars] [hex].
Recommended Action No action is required.
Error Message ACL-6-ACL_SPAN_DEST_CONFIG_STATUS: [chars] [chars].
Explanation ACL SPAN destination config event status is reported as [chars] [chars].
Recommended Action No action is required.
Error Message ACL-6-ACL_SPAN_SRC_CONFIG_STATUS: [chars] [chars].
Explanation ACL SPAN source config event status is reported as [chars] [chars].
Recommended Action No action is required.
This section contains the ASCII-CFG messages.
Error Message ASCII-CFG-2-CONFIG_REPLAY_STATUS: [chars] Replay [chars].
Explanation Bootstrap or Ascii Configuration Replay Status info.
Recommended Action No action is required.
Error Message ASCII-CFG-2-CONF_CONTROL: [chars]
Explanation Configuration restore control info.
Recommended Action No action is required.
Error Message ASCII-CFG-2-SYSERR_ACFG_NO_STARTUP_CFG_FILE: [chars]
Explanation Startup configuration file is empty
Recommended Action No action is required.
Error Message ASCII-CFG-3-ACFG_MTSERROR: [chars]
Explanation Ascii-cfg-server (rollback process) encountered an MTS error. [chars] specifies the context where the error occurred.
Recommended Action No action is required.
Error Message ASCII-CFG-6-INFORMATION: [chars]
Explanation An event happend that affects Acfg-Rollback. [chars] indicates the event
Recommended Action No action is required.
Error Message ASCII-CFG-6-PSS_ERR: [chars]
Explanation An error occurred during an Acfg PSS operation. [chars] indicates the PSS operation that caused the error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
This section contains the ASSOC_MGR messages.
Error Message ASSOC_MGR-0-EMERGENCY_MSG: [chars]
Explanation Association Manager Emergency Message
Recommended Action Please file the bug for Association Manager Component thro' CDETS
Error Message ASSOC_MGR-1-ALERT_MSG: [chars]
Explanation Association Manager Alert Message
Recommended Action Association Manager Internal Operation Alert
Error Message ASSOC_MGR-2-CRITICAL_MSG: [chars]
Explanation Association Manager Critical Message
Recommended Action No action is required.
Error Message ASSOC_MGR-3-ERROR_MSG: [chars]
Explanation Association Manager Error Message
Recommended Action No action is required.
Error Message ASSOC_MGR-4-WARN_MSG: [chars]
Explanation Association Manager Warning Message
Recommended Action No action is required.
Error Message ASSOC_MGR-5-NOTIF_MSG: [chars]
Explanation Association Manager Notification Message
Recommended Action No action is required.
Error Message ASSOC_MGR-6-ASSOC_ACTIVATED: Association Activated for vlan id:[dec] <--> vsan id:[dec]
Explanation Association Activated
Recommended Action No action is required.
Error Message ASSOC_MGR-6-ASSOC_CREATED: Association Created for vlan id:[dec] <--> vsan id:[dec]
Explanation Association Created
Recommended Action No action is required.
Error Message ASSOC_MGR-6-ASSOC_DEACTIVATED: Association Deactivated for vlan id: [dec] <--> vsan id: [dec]
Explanation Association Deactivated
Recommended Action No action is required.
Error Message ASSOC_MGR-6-ASSOC_DELETED: Association Deleted for vlan id: [dec] <--> vsan id: [dec]
Explanation Association Deleted
Recommended Action No action is required.
Error Message ASSOC_MGR-6-ASSOC_MGR_STATEFULL_RESTART: Association Manager Statefull Restart
Explanation Association Manager Stateful Restart
Recommended Action No action is required.
Error Message ASSOC_MGR-6-ASSOC_MGR_STATELESS_RESTART: Association Manager Stateless Restart
Explanation Association Manager Stateless Restart
Recommended Action No action is required.
Error Message ASSOC_MGR-6-ASSOC_OPER_STATUS_CHG: Association status for vlan id: [dec] <--> vsan id: [dec] changed from [chars] to [chars]
Explanation Association Operational State Change
Recommended Action No action is required.
Error Message ASSOC_MGR-6-INFO_MSG: [chars]
Explanation ASSOC Manager Informational Message
Recommended Action No action is required.
Error Message ASSOC_MGR-7-DEBUG_MSG: [chars]
Explanation Association Manager Debug Message
Recommended Action No action is required.
This section contains the BFD messages.
Error Message BFD-5-BFD_DISABLED: BFD Disabled
Explanation BFD Service Disabled
Recommended Action No action is required.
Error Message BFD-5-BFD_ENABLED: BFD Enabled
Explanation BFD Service enabled
Recommended Action No action is required.
This section contains the BLOGGERD messages.
Error Message BLOGGERD-2-BLOGGERD_SYSLOG_TRANSFER_ERROR_DISABLED: [chars]
Explanation Blogger Log Transfer has been error disabled
Recommended Action Please collect BloggerD tech support using 'show tech bloggerd-all'
Error Message BLOGGERD-3-BLOGGERD_INVALID_VDC: At [chars]([dec]) Invalid VDC [dec]
Explanation Invalid VDC ID
Recommended Action Please collect BloggerD tech support using 'show tech bloggerd-all'
Error Message BLOGGERD-3-BLOGGERD_LOG_DUMP_THROTTLED: VDC [dec] Comp: [chars] Buf_uuid: [dec] Buf_inst: [dec] sap: [chars]. Please collect 'show system internal sdwrap buffers sap [dec] detailed' from module [dec] Wiki: https://and-sw-web.cisco.com/twiki/bin/view/Sw/LogDumpThrottle
Explanation Log Dump Throttled
Recommended Action Please collect BloggerD tech support using 'show tech bloggerd-all'
Error Message BLOGGERD-3-BLOGGERD_MOVE_LOGS_SCRIPT_NOT_FOUND: At [chars]([dec]) Move Logs Script Not Found at [chars]
Explanation Move Log Script Not Found
Recommended Action Please collect BloggerD tech support using 'show tech bloggerd-all'
Error Message BLOGGERD-3-BLOGGERD_PATH_NOT_FOUND: At [chars]([dec]) Path [chars] NOT found
Explanation Required Path Not Found
Recommended Action Please collect BloggerD tech support using 'show tech bloggerd-all'
Error Message BLOGGERD-3-BLOGGERD_SYSLOG_CONFIG_PULL_FAILED: At [chars]([dec]) Config Pull Failed. Returned [hex]([chars])
Explanation Blogger Config Pull Failed
Recommended Action Please collect BloggerD tech support using 'show tech bloggerd-all'
Error Message BLOGGERD-3-BLOGGERD_SYSLOG_MTS_BIND_FAILED: MTS Bind Failed
Explanation MTS Bind Failed
Recommended Action Please collect BloggerD tech support using 'show tech bloggerd-all'
Error Message BLOGGERD-3-BLOGGERD_SYSLOG_MTS_UNDROP: MTS is not dropped by Node [hex] SAP [dec]
Explanation MTS not dropped
Recommended Action Please collect BloggerD tech support using 'show tech bloggerd-all'
Error Message BLOGGERD-3-BLOGGERD_SYSLOG_PSS_FAILURE: At [chars]([dec]) Internal PSS Error. Returned: [hex]([chars])
Explanation PSS Operation Failed
Recommended Action Please collect BloggerD tech support using 'show tech bloggerd-all'
Error Message BLOGGERD-3-BLOGGERD_SYSLOG_SDWRAP_INIT_FAILED: At [chars]([dec]) sdwrap initialization failed. Returned: [hex]([chars])
Explanation SDWrap Debug Init failed
Recommended Action Please collect BloggerD tech support using 'show tech bloggerd-all'
Error Message BLOGGERD-3-BLOGGERD_SYSLOG_THREAD_CREATE_FAILED: At [chars]([dec]) Thread Creation Failed [hex] errno: [dec]([chars])
Explanation Thread Creation Failed
Recommended Action Please collect BloggerD tech support using 'show tech bloggerd-all'
Error Message BLOGGERD-4-BLOGGERD_FLOW_CONTROL_ENABLED: Temporarily suspending BloggerD Log Transfer from Modules due to lack of space (available: %ld MB) on Active SUP
Explanation Flow Control Enabled. Transfer from Modules temporarily suspended
Recommended Action Please collect BloggerD tech support using 'show tech bloggerd-all'
Error Message BLOGGERD-4-BLOGGERD_FLOW_CONTROL_RESET: Revoking temporary Log Transfer Suspension from Modules. Space available now: %ld MB
Explanation Flow Control Reset. Transfer from Modules re-enabled
Recommended Action Please collect BloggerD tech support using 'show tech bloggerd-all'
Error Message BLOGGERD-6-BLOGGERD_INFO: [chars]
Explanation Info
Recommended Action Please collect BloggerD tech support using 'show tech bloggerd-all'
This section contains the CALLHOME messages.
Error Message CALLHOME-3-CALLHOME_CFS_MERGE_OPERATION_FAILED: [chars]
Explanation [chars1]
Recommended Action Please check the reason for the failure of the cfs operation and rectify the problem
Error Message CALLHOME-3-CALLHOME_CFS_OPERATION_FAILED: [chars] : [chars]
Explanation [chars1] [chars2]
Recommended Action Please check the reason for the failure of the cfs operation and rectify the problem
Error Message CALLHOME-3-CALLHOME_MAX_ALERT_MSG: [chars]
Explanation [chars]
Recommended Action Please check the reason for the generation of the callhome messages and rectify the problem
Error Message CALLHOME-6-NONCRIT_EVENT: [chars]
Explanation Non-critical Callhome event [chars] occurred.
Recommended Action If you have configured your email address to receive callhome notifications, please check your email for more details about this callhome event. If callhome was not enabled, please execute CLI commands relevant to the callhome event to get more information about the error
This section contains the CARDCLIENT messages.
Error Message CARDCLIENT-2-CARDCL_CRIT: [chars]
Explanation CardClient Critical Message
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message CARDCLIENT-2-FPGA_BOOT_GOLDEN: [chars] booted from Golden
Explanation CardClient fpga boot status
Recommended Action No action is required.
Error Message CARDCLIENT-2-FPGA_BOOT_PRIMARY: [chars] booted from Primary
Explanation CardClient fpga boot status
Recommended Action No action is required.
Error Message CARDCLIENT-2-FPGA_BOOT_STATUS: Unable to retrieve [chars] boot status
Explanation CardClient fpga boot status
Recommended Action No action is required.
Error Message CARDCLIENT-2-ONL: [chars]
Explanation Online Message
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message CARDCLIENT-2-REG: [chars]
Explanation CardClient Console Message
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message CARDCLIENT-2-SSE: [chars]
Explanation CardClient Console Message
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message CARDCLIENT-3-CARDCL_ERR: [chars]
Explanation CardClient Error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message CARDCLIENT-3-CARDCL_INFO: [chars]
Explanation CardClient Flow Message
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message CARDCLIENT-SLOT#-2-ERR: [chars]
Explanation CardClient Remote Syslog msg
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message CARDCLIENT-SLOT#-2-IMG_ERR: [chars]
Explanation CardClient Remote Syslog msg
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
This section contains the CDP messages.
Error Message CDP-2-INITFAIL: CDP Daemon Initialization failed: [chars]
Explanation CDP Daemon Initialization failed. [chars] explains the reason for the failure.
Recommended Action No action is required.
Error Message CDP-3-GENERROR: [chars]
Explanation CDP Daemon encountered a general error, one that does not fall in any of the above categories. [chars] describes the error and its context.
Recommended Action No action is required.
Error Message CDP-3-MTSERROR: [chars]
Explanation CDP Daemon encountered an MTS error. [chars] specifies the context where the error occurred.
Recommended Action No action is required.
Error Message CDP-3-PSSERROR: [chars]
Explanation CDP Daemon encountered a PSS error. [chars] specifies the context where the failure occurred.
Recommended Action No action is required.
Error Message CDP-5-DISABLED: CDP is disabled
Explanation CDP is disabled on the device.
Recommended Action No action is required.
Error Message CDP-5-ENABLED: CDP is enabled
Explanation CDP is enabled on the device.
Recommended Action No action is required.
Error Message CDP-6-CDPDUP: CDP Daemon Up.
Explanation CDP Daemon was created successfully and is up and running. This is an informational message.
Recommended Action No action is required.
Error Message CDP-6-PORTDISABLE: CDP disabled on port [chars]
Explanation CDP was disabled on a given port. [chars] is the interface-ID string that identifies the port. This is an informational message.
Recommended Action No action is required.
Error Message CDP-6-PORTDOWN: A CDP enabled port [chars] went down.
Explanation A CDP enabled port became un-operational. [chars] is the interface-ID string that identifies the port. This is an informational message.
Recommended Action No action is required.
Error Message CDP-6-PORTENABLE: CDP enabled on port [chars]
Explanation CDP was enabled on a given port. [chars] is the interface-ID string that identifies the port. This is an informational message.
Recommended Action No action is required.
Error Message CDP-6-PORTUP: A CDP enabled port [chars] came up.
Explanation A CDP enabled port became operational. [chars] is the interface-ID string that identifies the port. This is an informational message.
Recommended Action No action is required.
This section contains the CERT_ENROLL messages.
Error Message CERT_ENROLL-3-CERT_EN_ERROR_MESSAGE: [chars]
Explanation CERT_ENROLL Error Message
Recommended Action No action is required.
Error Message CERT_ENROLL-3-CERT_EN_FIPS_MODE_INIT_ERROR: Could not initialize FIPS mode : [chars]
Explanation FIPS mode initialization error
Recommended Action No action is required.
Error Message CERT_ENROLL-6-CERT_EN_MESSAGE: [chars]
Explanation CERT_ENROLL Message
Recommended Action No action is required.
This section contains the CFS messages.
Error Message CFS-2-GENERAL_ERROR: [chars]
Explanation The CFS service has encountered an critical error. The description of error is [str.]
Recommended Action No action is required.
Error Message CFS-2-PSS_ERROR: [chars]: PSS ret. val=[dec]
Explanation The CFS service encountered error while operating on a persistent storage database.
Recommended Action No action is required.
Error Message CFS-3-DBERROR: [chars]
Explanation CFS Service encountered a database error. [chars] specifies the context where the failure occured.
Recommended Action No action is required.
Error Message CFS-3-FAILURE_RESPONSE: [chars] [hex]
Explanation CFS Service failed to get response [chars][hex] specify the context where the failure occured.
Recommended Action No action is required.
Error Message CFS-3-GENERROR: [chars]
Explanation CFS Service encountered a general error, one that does not fall in any of the above categories. [chars] describes the error and its context.
Recommended Action No action is required.
Error Message CFS-3-LICERR: [chars]
Explanation CFS Service failed to get license.
Recommended Action No action is required.
Error Message CFS-3-MTSERROR: [chars]
Explanation CFS Service encountered an MTS error. [chars] specifies the context where the error occured.
Recommended Action No action is required.
Error Message CFS-3-PSSERROR: [chars]
Explanation CFS Service encountered a PSS error. [chars] specifies the context where the failure occured.
Recommended Action No action is required.
Error Message CFS-3-TIMEOUT_ERROR: [chars] [hex]
Explanation CFS Service encountered a timeout [chars][hex] specify the context where the failure occured.
Recommended Action No action is required.
Error Message CFS-4-LICEXP: [chars]
Explanation CFS Service license is going to expire. [chars] gives the expected time of expiry
Recommended Action No action is required.
Error Message CFS-6-SRVCREATED: CFS Service created
Explanation CFS Service was created successfully and is up and running. This is an informational message.
Recommended Action No action is required.
This section contains the CLK_MGR messages.
Error Message CLK_MGR-2-CLK_MGR_FC2_CRIT: CLK_MGR critical error: [chars]
Explanation CLK_MGR fc2 clock synchronization critical error
Recommended Action No action is required.
Error Message CLK_MGR-5-CLK_MGR_CLI_CONFIG: CLK_MGR clock is synchronized by [chars] from VDC [dec]
Explanation CLK_MGR clock is synchronized by [chars] from VDC
Recommended Action No action is required.
Error Message CLK_MGR-6-CLK_MGR_TSTAMP_CHKS_DISABLED: CLK_MGR timestamp checks disabled: [chars]
Explanation CLK_MGR timestamp checks disabled
Recommended Action No action is required.
Error Message CLK_MGR-6-CLK_MGR_TSTAMP_CHKS_ENABLED: CLK_MGR timestamp checks enabled
Explanation CLK_MGR timestamp checks enabled
Recommended Action No action is required.
This section contains the CLOUD messages.
Error Message CLOUD-3-CLOUD_CFS_MERGE_OPERATION_FAILED: [chars]
Explanation [chars1]
Recommended Action Please check the reason for the failure of the cfs operation and rectify the problem
Error Message CLOUD-3-CLOUD_CFS_OPERATION_FAILED: [chars] : [chars]
Explanation [chars1] [chars2]
Recommended Action Please check the reason for the failure of the cfs operation and rectify the problem
Error Message CLOUD-3-CLOUD_FEATURE_MANAGER_ERROR: [chars] : [chars]
Explanation [chars1] [chars2]
Recommended Action Please check the reason for error using feature manager and rectify the problem
Error Message CLOUD-3-CLOUD_PSS_OPERATION_FAILED: [chars] : [chars]
Explanation [chars1] [chars2]
Recommended Action Please check the reason for the failure of the pss operation and rectify the problem
Error Message CLOUD-6-CLOUD_DISCOVERY_DONE: discovery over
Explanation Cloud-discovery started
Recommended Action Check cloud membership
This section contains the CMOND messages.
Error Message CMOND-2-CMOND_ALERT_MSG: [chars]
Explanation Alert message
Recommended Action No action is required.
Error Message CMOND-2-CMOND_ERROR_MSG: [chars]
Explanation Error message
Recommended Action No action is required.
This section contains the COPP messages.
Error Message COPP-5-COPP_DISABLED: COPP Disabled
Explanation COPP Service Disabled
Recommended Action No action is required.
Error Message COPP-5-COPP_ENABLED: COPP Enabled
Explanation COPP Service nabled
Recommended Action No action is required.
Error Message COPP-5-COPP_INIT: COPP initialized
Explanation COPP Service Initialized
Recommended Action No action is required.
This section contains the CRDCFG messages.
Error Message CRDCFG-2-CRDCFG_SRV_CRIT: [chars]
Explanation CardConfig CRITICAL ERROR
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message CRDCFG-3-CRDCFG_ERR: [chars]
Explanation CardConfig error mesage
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message CRDCFG-3-CRDCFG_MSG: [chars]
Explanation CardConfig log mesage
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message CRDCFG-3-CRDCFG_SRV_ERR: [chars]
Explanation CardConfigServer error mesage
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message CRDCFG-3-CRDCFG_SRV_MSG: [chars]
Explanation CardConfigServer log mesage
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message CRDCFG-SLOT#-2-CONFIG_ERR: [chars]
Explanation CardConfig Failed to find matching cardid, pnum in database
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
This section contains the DCEFIB messages.
Error Message DCEFIB-SLOT#-2-U2FIB_ERR: [chars]
Explanation L2mp unicast fib encountered an error:
Recommended Action No action is required.
Error Message DCEFIB-SLOT#-6-U2FIB_INFO: [chars]
Explanation L2mp unicast fib notice:
Recommended Action No action is required.
This section contains the DEVICE-ALIAS messages.
Error Message DEVICE-ALIAS-2-INIT_FAILED: [chars]
Explanation An error occurred during initialization. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-CFS_OPER_FAILED: [chars]
Explanation An error occurred while performing a CFS operation. [chars] indicates the CFS operation and the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-CLEAR_FAILED: [chars]
Explanation An error occurred while clearing the session. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-COMMIT_FAILED: [chars]
Explanation An error occurred while committing the database. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-COMMIT_REJECTED: [chars]
Explanation Commit request received from remote switch is rejected. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-LOCK_FAILED: [chars]
Explanation An error occurred while acquiring the lock. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-LOCK_REJECTED: [chars]
Explanation Lock request received from remote switch is rejected. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-MERGE_ACTIVATION_FAILED: [chars]
Explanation An error occurred while activating the merged database. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-MERGE_ACTIVATION_REJECTED: [chars]
Explanation Merge activation request received from remote switch is rejected. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-MERGE_FAILED: [chars]
Explanation An error occurred during merge operation. [chars] indicates the reason for failure.
Recommended Action Compare device-alias configuration with the other switches in the fabric, resolve the conflicts if any and commit the changes.
Error Message DEVICE-ALIAS-3-MERGE_MREQ_REJECTED: [chars]
Explanation MREQ received from remote switch is rejected. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-MERGE_MRESP_REJECTED: [chars]
Explanation MRESP received from remote switch is rejected. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-MERGE_VALIDATION_FAILED: [chars]
Explanation An error occurred while validating the merged database. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-MERGE_VALIDATION_REJECTED: [chars]
Explanation Merge validation request received from remote switch is rejected. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-MTS_OPER_FAILED: [chars]
Explanation An error occurred during MTS operation. [chars] indicates the MTS operation and the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-PSS_OPER_FAILED: [chars]
Explanation An error occurred during PSS operation. [chars] indicates the PSS operation and the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-UNLOCK_FAILED: [chars]
Explanation An error occurred while releasing the lock. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-UNLOCK_REJECTED: [chars]
Explanation Unlock request received from remote switch is rejected. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-VALIDATION_FAILED: [chars]
Explanation An error occurred while validating the database. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-VALIDATION_REJECTED: [chars]
Explanation Validation request received from remote switch is rejected. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-6-CLEAR_FAILED_INFO: [chars]
Explanation An error occurred while clearing the session. [chars] indicates the additional information regarding failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-6-COMMIT_FAILED_INFO: [chars]
Explanation An error occurred while committing the database. [chars] indicates the additional information regarding failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-6-LOCK_FAILED_INFO: [chars]
Explanation An error occurred while acquiring the lock. [chars] indicates the additional information regarding failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-6-MERGE_ACTIVATION_FAILED_INFO: [chars]
Explanation An error occurred while activating the merged database. [chars] indicates the additional information regarding failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-6-MERGE_VALIDATION_FAILED_BUSY: [chars]
Explanation Merged database could not be validated as some of the applications returned busy. [chars] indicates information about the application returned busy. There is no user intervention necessary. The validation would be automatically retried after some time.
Recommended Action No DDTS.
Error Message DEVICE-ALIAS-6-MERGE_VALIDATION_REJECTED_BUSY: [chars]
Explanation Merged database received from the remote switch could not be validated as some of the applications returned busy. [chars] indicates information about the application returned busy. There is no user intervention necessary. The validation would be automatically retried after some time.
Recommended Action No DDTS.
Error Message DEVICE-ALIAS-6-UNLOCK_FAILED_INFO: [chars]
Explanation An error occurred while releasing the lock. [chars] indicates the additional information regarding failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-6-VALIDATION_ABORTED: [chars]
Explanation Local validation is aborted. [chars] indicates the reason why validation is aborted.
Recommended Action No DDTS.
This section contains the DEV_LOG_SUP messages.
Error Message DEV_LOG_SUP-3-ERROR: [chars]
Explanation Dev_log_sup encountered an error
Recommended Action No action is required.
This section contains the DEV_LOG messages.
Error Message DEV_LOG-3-ERROR: [chars]
Explanation Dev_log_lc encountered an error
Recommended Action No action is required.
Error Message DEV_LOG-SLOT#-4-DEV_LOG_LC_ERROR: [chars]
Explanation Dev_log_lc encountered an error
Recommended Action No action is required.
This section contains the DHCLIENT messages.
Error Message DHCLIENT-2-DHCLIENT_DISCOVER_RECVD_NAK: [chars] - Received DHCP NAK
Explanation Received DHCP NAK
Recommended Action No action is required.
Error Message DHCLIENT-2-DHCLIENT_DISCOVER_START: [chars] - DHCLIENT DHCP Discover phase started
Explanation DHCLIENT DHCP Discover phase started
Recommended Action No action is required.
Error Message DHCLIENT-2-DHCLIENT_FAILURE: [chars]
Explanation DHCLIENT Failure
Recommended Action No action is required.
Error Message DHCLIENT-2-DHCLIENT_FLASH_FULL: DHCLIENT bootflash doesn't have enough space (85% FULL)
Explanation DHCLIENT bootflash doesn't have enough space (85% FULL)
Recommended Action No action is required.
Error Message DHCLIENT-2-DHCLIENT_INITED: [chars] - DHCLIENT process initialized
Explanation DHCLIENT process initialized
Recommended Action No action is required.
Error Message DHCLIENT-2-DHCLIENT_SCRIPT_DOWNLOADED: [chars] - Successfully downloaded DHCLIENT script file
Explanation Successfully downloaded DHCLIENT script file
Recommended Action No action is required.
Error Message DHCLIENT-2-DHCLIENT_SCRIPT_STARTED_MD5_NOT_VALIDATED: [chars] - DHCLIENT script execution started(MD5 not validated)
Explanation DHCLIENT script execution started(MD5 not validated)
Recommended Action No action is required.
Error Message DHCLIENT-2-DHCLIENT_SCRIPT_STARTED_MD5_VALIDATED: [chars] - DHCLIENT script execution started(MD5 validated)
Explanation DHCLIENT script execution started(MD5 validated)
Recommended Action No action is required.
Error Message DHCLIENT-2-DHCLIENT_SCRIPT_STARTED_MD5_VALIDATION_FAIL: [chars] - DHCLIENT boot file validation failed
Explanation DHCLIENT boot file validation failed.
Recommended Action No action is required.
Error Message DHCLIENT-4-DHCLIENT_WARNING: [chars]
Explanation DHCLIENT Warning
Recommended Action No action is required.
Error Message DHCLIENT-5-DHCLIENT_DISABLED: [chars] - DHCLIENT Disabled
Explanation DHCLIENT Service Disabled
Recommended Action No action is required.
Error Message DHCLIENT-5-DHCLIENT_ENABLED: [chars] - DHCLIENT Enabled
Explanation DHCLIENT Service nabled
Recommended Action No action is required.
Error Message DHCLIENT-6-DHCLIENT_INFO: [chars]
Explanation DHCLIENT Info
Recommended Action No action is required.
Error Message DHCLIENT-7-DHCLIENT_DEBUG: [chars]
Explanation DHCLIENT Debug
Recommended Action No action is required.
This section contains the DHCP_SNOOP messages.
Error Message DHCP_SNOOP-2-DHCP_SNOOP_PROGRAM_EXIT: [chars]
Explanation DHCP snoop process did an abnormal exit
Recommended Action No action is required.
Error Message DHCP_SNOOP-2-INITFAIL: DHCP Daemon Initialization failed: [chars]
Explanation DHCP Daemon Initialization failed. [chars] explains the reason for the failure.
Recommended Action No action is required.
Error Message DHCP_SNOOP-2-PSSERROR: [chars]
Explanation DHCP Daemon encountered a PSS error. [chars] specifies the context where the failure occurred.
Recommended Action No action is required.
Error Message DHCP_SNOOP-3-ASSERTION_FAILED: [chars]:[dec]
Explanation DHCP Snoop process has hit an assert condition at file [chars] line number [dec]
Recommended Action No action is required.
Error Message DHCP_SNOOP-3-IPV6APIINIT_FAILED: [chars]
Explanation DHCP Snoop process failed to do ipv6_api_init [chars]
Recommended Action No action is required.
Error Message DHCP_SNOOP-3-IPV6REGISTER_FAILED: [chars]
Explanation DHCP Snoop process failed to do ipv6_register [chars]
Recommended Action No action is required.
Error Message DHCP_SNOOP-3-MTSERROR: [chars]
Explanation DHCP Daemon encountered an MTS error. [chars] specifies the context where the error occurred.
Recommended Action No action is required.
Error Message DHCP_SNOOP-5-VLANENABLE: DHCP Snooping enabled on vlan [dec]
Explanation DHCP Snooping was enabled on a given vlan. [dec] is the VLAN-ID that identifies the vlan. This is an informational message.
Recommended Action No action is required.
Error Message DHCP_SNOOP-6-DHCPUP: DHCP Daemon Up.
Explanation DHCP Daemon was created successfully and is up and running. This is an informational message.
Recommended Action No action is required.
Error Message DHCP_SNOOP-6-INTFDISABLE: IP Src Guard disabled on intf [chars]
Explanation IP Src Guard was disabled on a given intf. [chars] is the intf-ID string that identifies the intf. This is an informational message.
Recommended Action No action is required.
Error Message DHCP_SNOOP-6-INTFENABLE: IP Src Guard enabled on intf [chars]
Explanation IP Src Guard was enabled on a given intf. [chars] is the intf-ID string that identifies the intf. This is an informational message.
Recommended Action No action is required.
Error Message DHCP_SNOOP-6-OPT82INSTFAIL: [chars] [chars]
Explanation Insertion of Option82 suboptions failed. [chars] tells the failure. [chars] explains the reason for failure. This is an informational message.
Recommended Action No action is required.
This section contains the DIAG_PORT_LB messages.
Error Message DIAG_PORT_LB-5-DIAG_PORT_LB_DISABLED: DIAG_PORT_LB Disabled
Explanation DIAG_PORT_LB Service Disabled
Recommended Action No action is required.
Error Message DIAG_PORT_LB-5-DIAG_PORT_LB_ENABLED: DIAG_PORT_LB Enabled
Explanation DIAG_PORT_LB Service nabled
Recommended Action No action is required.
This section contains the DOT1X messages.
Error Message DOT1X-5-DOT1X_DISABLED: dot1x Disabled
Explanation Dot1x Service Disabled
Recommended Action No action is required.
Error Message DOT1X-5-DOT1X_ENABLED: dot1x Enabled
Explanation Dot1x Service Enabled
Recommended Action No action is required.
Error Message DOT1X-5-DOT1X_NOTIF: [chars]
Explanation Dot1x Notification
Recommended Action No action is required.
This section contains the DPVM messages.
Error Message DPVM-2-DPVM_DUPL_REJECT: [chars]
Explanation Rejected duplicate pwwn query
Recommended Action Dpvm overwrite-duplicate-pwwn
Error Message DPVM-3-DB_ERR: [chars]
Explanation An error occured during an DPVM database operation. [chars] indicates the reason for the error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DPVM-3-DDAS_MODE_INVALID: [chars]
Explanation DDAS mode Invalid. [chars]
Recommended Action Flip DDAS mode
Error Message DPVM-3-INIT_FAIL: [chars]
Explanation An error happened during DPVM Initialization. [chars] indicates the reason for failure
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DPVM-3-MTS_ERR: [chars]
Explanation An error occured in processing of an MTS message. [chars] indicates the error that occured
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DPVM-3-PSS_ERR: [chars]
Explanation An error occured during an DPVM PSS operation. [chars] indicates the PSS operation that caused the error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DPVM-4-ACTIVATION_FAIL: [chars]
Explanation Activation of DPVM device mappings failed due to [chars]
Recommended Action Correct the error and reactivate database again
Error Message DPVM-4-FEATURE_DISABLED: [chars]
Explanation DPVM is unavailable and disabled now
Recommended Action No action is required.
Error Message DPVM-6-FEATURE_ENABLED: [chars]
Explanation DPVM is available and enabled now
Recommended Action No action is required.
Error Message DPVM-6-INFO: [chars]
Explanation An event happened that affects DPVM. [chars] indicates the event
Recommended Action No action is required.
This section contains the DSTATS messages.
Error Message DSTATS-3-PSS_CREATE_FAIL: pss create runtime database failed due to error: [hex]
Explanation Dstats process pss create runtime database failure due to error [hex].
Recommended Action Collect more information using command 'show flash'. See pss system error codes for reason.
Error Message DSTATS-3-PSS_DELETE_FAIL: pss delete runtime entry key:[hex] failed due to error: [hex]
Explanation Dstats process pss delete runtime entry key [hex] failure due to error [hex].
Recommended Action Collect more information using command 'show flash'. See pss system error codes for reason.
Error Message DSTATS-3-PSS_MAX_KEY_FAIL: pss set runtime max key failed due to error: [hex]
Explanation Dstats process pss set runtime max key failure due to error [hex].
Recommended Action Collect more information using command 'show flash'. See pss system error codes for reason.
Error Message DSTATS-3-PSS_MAX_VALUE_FAIL: pss set runtime max value failed due to error: [hex]
Explanation Dstats process pss set runtime max value failure due to error [hex].
Recommended Action Collect more information using command 'show flash'. See pss system error codes for reason.
Error Message DSTATS-3-PSS_OPEN_FAIL: pss open runtime database failed due to error: [hex]
Explanation Dstats process pss open runtime database failure due to error [hex].
Recommended Action Collect more information using command 'show flash'. See pss system error codes for reason.
Error Message DSTATS-3-PSS_RELOAD_FAIL: pss reload runtime database failed due to error: [hex]
Explanation Dstats process pss reload runtime database failure due to error [hex].
Recommended Action Collect more information using command 'show flash'. See pss system error codes for reason.
Error Message DSTATS-3-PSS_SNAPSHOT_DEBUG_FAIL: pss snapshot runtime debug to uri:[chars] failed due to error: [hex]
Explanation Dstats process pss snapshot of runtime debug to uri [string] failed due to error [hex].
Recommended Action Collect more information using command 'show flash'. See pss system error codes for reason.
Error Message DSTATS-3-PSS_SNAPSHOT_FAIL: pss snapshot runtime to uri:[chars] failed due to error: [hex]
Explanation Dstats process pss snapshot of runtime to uri [string] failed due to error [hex].
Recommended Action Collect more information using command 'show flash'. See pss system error codes for reason.
Error Message DSTATS-3-PSS_STORE_FAIL: pss store runtime entry key:[hex] val:[hex] failed due to error: [hex]
Explanation Dstats process pss store runtime entry key [hex] value [hex] failure due to error [hex].
Recommended Action Collect more information using command 'show flash'. See pss system error codes for reason.
This section contains the ECHAT messages.
Error Message ECHAT-2-ECHAT_STATUS: TEST: [chars].
Explanation ECHAT status is reported as [chars].
Recommended Action No action is required.
This section contains the EOU messages.
Error Message EOU-5-L2NAC_DISABLED: EOU Disabled
Explanation Service EOU Disabled
Recommended Action No action is required.
Error Message EOU-5-L2NAC_ENABLED: EOU Enabled
Explanation Service EOU enabled
Recommended Action No action is required.
This section contains the EPP messages.
Error Message EPP-5-EPP_FAILURE: Interface [chars] EPP Failure
Explanation Trunk protocol failed
Recommended Action 'show epp internal event-history err' will indicate the errors encountered
This section contains the ETH-PORT-SEC messages.
Error Message ETH-PORT-SEC-2-ETH_PORT_SEC_ADDR_SEEN: MAC address already secured on peer-switch. Please re-configure after VPC comes up, if this interface is supposed to be a VPC PO
Explanation Mac already secured on peer
Recommended Action No action is required.
Error Message ETH-PORT-SEC-2-ETH_PORT_SEC_MISCONFIG: MAC Addresses present exceed the allowed number of MAC addresses on Port [chars]. Fix the inconsistency on this port.
Explanation MAC Addresses present exceed the allowed number of MAC addresses.
Recommended Action No action is required.
Error Message ETH-PORT-SEC-2-ETH_PORT_SEC_REGMAC_ADD_FAIL: Unable to add regmac [chars] for <[chars], vlan [dec]> since it is already registered for <[chars], vlan [dec]>
Explanation Duplicate regmac detected
Recommended Action No action is required.
Error Message ETH-PORT-SEC-2-ETH_PORT_SEC_SECURITY_VIOLATION: Triggered violation [chars] on Port [chars]
Explanation Violation action triggered on port due to security violation.
Recommended Action No action is required.
Error Message ETH-PORT-SEC-3-ETH_PORT_SEC_CONFIG_MAC_FAILED: Failed to configure MACs
Explanation Failed to configure MACs
Recommended Action No action is required.
Error Message ETH-PORT-SEC-3-ETH_PORT_SEC_INVALID_VLAN: Invalid VLAN configuration
Explanation Invalid VLAN configuration
Recommended Action No action is required.
Error Message ETH-PORT-SEC-3-ETH_PORT_SEC_PKTSENDFAIL: Failed to send packet, - [chars]
Explanation Failed to send packet. [char] identifies the reason.
Recommended Action No action is required.
Error Message ETH-PORT-SEC-3-ETH_PORT_SEC_SECURITY_VIOLATION_ANOTHER_PORT: Host [chars] bound to Port [chars] in Vlan [dec] is trying to access Port [chars] in Vlan [dec]
Explanation Moved the port to violation state due to a mac address seen on one port being seen on another
Recommended Action No action is required.
Error Message ETH-PORT-SEC-3-ETH_PORT_SEC_SECURITY_VIOLATION_MAX_MAC_VLAN: Port [chars] moved to [chars] state as host [chars] is trying to access the port in vlan [dec]
Explanation Moved the port to violation state due to exceeding address count
Recommended Action No action is required.
Error Message ETH-PORT-SEC-3-ETH_PORT_SEC_UNABLE_TO_DISABLE: Unable to disable eth_port_sec [chars].
Explanation Unable to disable eth_port_sec Service
Recommended Action No action is required.
Error Message ETH-PORT-SEC-3-ETH_PORT_SEC_UNABLE_TO_ENABLE: Unable to enable eth_port_sec [chars].
Explanation Unable to enable eth_port_sec Service
Recommended Action No action is required.
Error Message ETH-PORT-SEC-3-ETH_PORT_SEC_VIOL_UPDATE_FAILED: Failed to update violation mode
Explanation Failed to update violation mode
Recommended Action No action is required.
Error Message ETH-PORT-SEC-5-ETH_PORT_SEC_AGE_TIME_EXPIRY: Age Time expired for host [chars] in VLAN [dec] in port [chars]
Explanation Age time expired for host
Recommended Action No action is required.
Error Message ETH-PORT-SEC-5-ETH_PORT_SEC_DISABLED: eth_port_sec Disabled on if_index:[hex]
Explanation Eth_port_sec Service Disabled
Recommended Action No action is required.
Error Message ETH-PORT-SEC-5-ETH_PORT_SEC_DYNAMIC_MAC_ADDRESS_CLEARED: Dynamic MAC addresses for port [chars] cleared
Explanation Dynamic MAC address for port cleared
Recommended Action No action is required.
Error Message ETH-PORT-SEC-5-ETH_PORT_SEC_ENABLED: eth_port_sec Enabled on if_index:[hex]
Explanation Eth_port_sec Service Enabled
Recommended Action No action is required.
Error Message ETH-PORT-SEC-5-ETH_PORT_SEC_HOST_ADDITION: A new Host [chars] learnt on Port [chars] in Vlan [dec]
Explanation A new host is learnt on a port
Recommended Action No action is required.
Error Message ETH-PORT-SEC-5-ETH_PORT_SEC_HOST_DELETION: Host [chars] bound to secure port [chars] in Vlan [dec] has been removed
Explanation A host has been removed
Recommended Action No action is required.
Error Message ETH-PORT-SEC-5-ETH_PORT_SEC_INITFAIL: Eth Port Security Initialization failed: [chars]
Explanation Eth Port Security Initialization failed.[chars] explains the reason for the failure.
Recommended Action No action is required.
Error Message ETH-PORT-SEC-5-ETH_PORT_SEC_MAX_LIMIT_EXCEED: Max Addr per port config cannot be accepted as it will violate the System Max limit. [chars]
Explanation System wide Max Limit Exceeds
Recommended Action No action is required.
This section contains the ETH_PORT_CHANNEL messages.
Error Message ETH_PORT_CHANNEL-3-ADD_REM_MEMBERS_FAILURE: [chars]
Explanation Some service(s) failed to add or remove ports to port-channel
Recommended Action None
Error Message ETH_PORT_CHANNEL-3-CLEAR_PORT_CLIENT_STATS_FAILURE: [chars]
Explanation Failed to clear stats for port [chars] err: [hex] ([chars])
Recommended Action None
Error Message ETH_PORT_CHANNEL-3-GENERAL_ERROR: [chars]
Explanation General error
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-3-RESOURCE_ALLOC_FAILED_PORT_CHANNEL_DELETED: [chars] deleted
Explanation Port-channel deleted from running config
Recommended Action May need to re-configure the port-channel and its members
Error Message ETH_PORT_CHANNEL-3-SHADOW_MBR_CHANGE_FAILURE: [chars]
Explanation Some service failed shadow member change to port-channel
Recommended Action None
Error Message ETH_PORT_CHANNEL-3-SHADOW_PC_CREATE_FAILURE: [chars]
Explanation Some service failed shadow port-channel create
Recommended Action None
Error Message ETH_PORT_CHANNEL-3-SHADOW_PC_DELETE_FAILURE: [chars]
Explanation Some service failed shadow port-channel delete
Recommended Action None
Error Message ETH_PORT_CHANNEL-4-PORT_CFG_DELETED: [chars] removed from [chars] (different module inserted)
Explanation Port is removed from a port-channel because a different module was inserted to the same slot
Recommended Action You lost some ports from port-channel, check if you want to add ports in the new module to the same port-channel.
Error Message ETH_PORT_CHANNEL-4-RACE_WARN: [chars]
Explanation Warning of possible race condition
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-5-CREATED: [chars] created
Explanation A port-channel is created
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-5-DELETED: [chars] deleted
Explanation A port-channel is deleted
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-5-PORT_ADDED: [chars] added to [chars]
Explanation Ports are added to a port-channel
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-5-PORT_REMOVED: [chars] removed from [chars]
Explanation Ports are removed from a port-channel
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-5-PORT_WAIT_BFD: [chars] waiting for BFD session to get established
Explanation Port waiting for BFD session establishment
Recommended Action None
This section contains the EVMED messages.
Error Message EVMED-5-EVMED_DISABLED: Event Detectors Disabled
Explanation Event manager event detector service disabled
Recommended Action No action is required.
Error Message EVMED-5-EVMED_ENABLED: Event Detectors Enabled
Explanation Event manager event detector service enabled
Recommended Action No action is required.
This section contains the EXAMPLE_TEST messages.
Error Message EXAMPLE_TEST-5-EXAMPLE_TEST_DISABLED: EXAMPLE_TEST Disabled
Explanation EXAMPLE_TEST Service Disabled
Recommended Action No action is required.
Error Message EXAMPLE_TEST-5-EXAMPLE_TEST_ENABLED: EXAMPLE_TEST Enabled
Explanation EXAMPLE_TEST Service nabled
Recommended Action No action is required.
This section contains the EX_SYSLOG messages.
Error Message EX_SYSLOG-0-EMER_MSG: Emergency Message - [dec]
Explanation A Dummy emergency message to test syslogd from ex_syslog. [dec] is the message count
Recommended Action No action is required.
Error Message EX_SYSLOG-1-ALERT_MSG: Alert Message - [chars] [dec]
Explanation A Dummy alert message to test syslogd from ex_syslog. [chars] is the a dummy text. [dec] is the message count
Recommended Action No action is required.
Error Message EX_SYSLOG-2-CRIT_MSG: Critical Message - [dec]
Explanation A Dummy critical message to test syslogd from ex_syslog. [dec] is the message count
Recommended Action No action is required.
Error Message EX_SYSLOG-3-ERR_MSG: Error Message - [dec]
Explanation A Dummy error message to test syslogd from ex_syslog. [dec] is the message count
Recommended Action No action is required.
Error Message EX_SYSLOG-4-WARNING_MSG: Warning Message - [dec]
Explanation A Dummy warning message to test syslogd from ex_syslog. [dec] is the message count
Recommended Action No action is required.
Error Message EX_SYSLOG-5-NOTICE_MSG: Notice Message - [dec]
Explanation A Dummy notice message to test syslogd from ex_syslog. [dec] is the message count
Recommended Action No action is required.
Error Message EX_SYSLOG-6-INFO_MSG: Info Message - [dec]
Explanation A Dummy info message to test syslogd from ex_syslog. [dec] is the message count
Recommended Action No action is required.
Error Message EX_SYSLOG-7-DEBUG_MSG: Debug Message - [dec]
Explanation A Dummy debug message to test syslogd from ex_syslog. [dec] is the message count
Recommended Action No action is required.
This section contains the FABRICPATH messages.
Error Message FABRICPATH-2-FABRICPATH_LINK_BRINGUP_STALLED_STATIC: Link bringup stalled due to conflicts: [chars]
Explanation Interface is disabled due to conflicts
Recommended Action No action is required.
This section contains the FC-TUNNEL messages.
Error Message FC-TUNNEL-3-INTERNAL_ERROR: Internal error: [chars]
Explanation FCMPLS tunnel process encountered a general error, one that does not fall in any of the categories. [chars] describes the error and its context.
Recommended Action No action is required.
This section contains the FCFWD messages.
Error Message FCFWD-3-ERROR: [chars]
Explanation Fcfwd encountered an error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FCFWD-4-WARNING: [chars]
Explanation Fcfwd is generating a relevant notification
Recommended Action No action is required.
Error Message FCFWD-6-INFO: [chars]
Explanation An fcfwd event occurred
Recommended Action No action is required.
Error Message FCFWD-SLOT#-2-FIB_MCAST_LIMIT_REACHD: Multicast Route Limit Exceeded.
Explanation The Multicast Route Limit in the host table has reached.
Recommended Action No action is required.
This section contains the FCNS messages.
Error Message FCNS-2-DB_HARD_LIMIT: : [chars]
Explanation Name server database is full. The max number of entries, [dec], of ports is already present in the database
Recommended Action No action is required.
Error Message FCNS-2-DB_SOFT_LIMIT: : [chars]
Explanation Number of FCNS DB entries should not exceed scale soft limit.
Recommended Action No action is required.
Error Message FCNS-2-INIT_FAILURE: : [chars]
Explanation Fcns initialisation has failed due to [chars].
Recommended Action No action is required.
Error Message FCNS-2-NO_RESPONSE: for query [chars] from domain [dec]
Explanation No response for query [chars] from domain [dec].
Recommended Action No action is required.
Error Message FCNS-2-PSS_VERSION_MISMATCH: : for [chars]
Explanation Version mismatch for pss of type [chars].
Recommended Action No action is required.
Error Message FCNS-2-RELOAD_FAILURE: : [chars]
Explanation Failed to reload information from PSS: [chars].
Recommended Action No action is required.
Error Message FCNS-3-BAD_FRAME: : [chars]
Explanation Received a bad frame from the network: [chars].
Recommended Action No action is required.
Error Message FCNS-3-CFG_FAILURE: : [chars]
Explanation A failure related to fcns configuration: [chars].
Recommended Action No action is required.
Error Message FCNS-3-CHUNK_FAILURE: : [chars]
Explanation Chunk memory failure: [chars].
Recommended Action No action is required.
Error Message FCNS-3-DB_FAILURE: : [chars]
Explanation A failure occured in fcns database: [chars].
Recommended Action No action is required.
Error Message FCNS-3-MALLOC_FAILURE: : [chars]
Explanation Malloc failed: [chars].
Recommended Action No action is required.
Error Message FCNS-3-MGMT_SEC_SDB_ERR: [chars] : [chars]
Explanation Mgmt-security shared-db [chars] : [chars].
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FCNS-3-MTS_FAILURE: : [chars] [chars]
Explanation Failure occured trying to do an MTS operation: [chars] [chars].
Recommended Action No action is required.
Error Message FCNS-3-PSS_FAILURE: : [chars]
Explanation Pss failure: [chars].
Recommended Action No action is required.
Error Message FCNS-4-QUERY_NO_RESPONSE: for query [chars] from domain [dec]
Explanation No response for query [chars] from domain [dec].
Recommended Action No action is required.
Error Message FCNS-6-DB_INFO: : [chars] [hex]
Explanation Database modification:[chars] for entry [hex].
Recommended Action No action is required.
Error Message FCNS-6-PORT_NAME_MODIFY: FCID: [chars] Modifying pwwn from [chars] to [chars]. Collect fcns/fcr tech-support and logs
Explanation Port Name for an existing NS entry is being changed
Recommended Action No action is required.
Error Message FCNS-6-STATUS_INFO: : [chars]
Explanation A change in fcns status: [chars].
Recommended Action No action is required.
This section contains the FCOE_MGR messages.
Error Message FCOE_MGR-2-FCOE_MGR_MODULE_NOT_LICENSED: FCoE Manager Module:[dec] not licensed
Explanation FCOE_MGR Line Card not licensed
Recommended Action No action is required.
Error Message FCOE_MGR-5-FCOE_MGR_DISABLED: FCOE_MGR Disabled
Explanation FCOE_MGR Service Disabled
Recommended Action No action is required.
Error Message FCOE_MGR-5-FCOE_MGR_ENABLED: FCOE_MGR Enabled
Explanation FCOE_MGR Service Enabled
Recommended Action No action is required.
Error Message FCOE_MGR-5-FCOE_MGR_MODULE_LICENSE_CHECKIN: FCoE Manager License Checkin:[dec]
Explanation FCOE_MGR Line Card license checked in
Recommended Action No action is required.
Error Message FCOE_MGR-5-FCOE_MGR_MODULE_LICENSE_CHECKOUT: FCoE Manager License Checkout:[dec]
Explanation FCOE_MGR Line Card license checked out
Recommended Action No action is required.
Error Message FCOE_MGR-5-FCOE_MGR_SOLICITATION_FROM_SAME_MAC: FCoE Manager received Mulicast Solication from same MAC: [chars]
Explanation FCoE Manager received Mulicast Solication from same MAC
Recommended Action No action is required.
Error Message FCOE_MGR-5-FCOE_MGR_VE_DUPLICATE_PEER_MAC: FCoE Manager has already received unicast advertisement from MAC [chars] on a different VE link. Bringing down this link
Explanation FCoE Manager has already received unicast advertisement from same MAC on a different VE link
Recommended Action No action is required.
This section contains the FCS messages.
Error Message FCS-2-RANDNUM_FAIL: [chars]
Explanation There was a critical error during random number generation. [chars] indicates details of the error
Recommended Action No action is required.
Error Message FCS-3-DB_ERR: [chars]
Explanation An error occurred during an FCS database operation. [chars] indicates the reason for the error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FCS-3-FCS_MGMT_SEC_SDB_ERR: [chars] : [chars]
Explanation FC CT Mgmt Security shared db operation : [chars] : [chars].
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FCS-3-INIT_FAIL: [chars]
Explanation An error happened during FCS Initialization. [chars] indicates the reason for failure
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FCS-3-MTS_API_ERR: [chars] : [chars]
Explanation An error occurred in send or receive of an MTS message. [chars] indicates the error that occurred and [chars] indicates the error number
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FCS-3-MTS_ERR: [chars]
Explanation An error occurred in processing of an MTS message. [chars] indicates the error that occurred
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FCS-3-NO_MTS_RESP: [chars]
Explanation There was no response to an MTS request. [chars] indicates details of the MTS message
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FCS-3-OTHER_ERR: [chars]
Explanation An FCS generic error occurred. [chars] indicates the description of the error
Recommended Action No action is required.
Error Message FCS-3-PSS_ERR: [chars]
Explanation An error occurred during an FCS PSS operation. [chars] indicates the PSS operation that caused the error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FCS-3-SOCK_ERR: sd: [dec], [chars]
Explanation An FC-2 Socket error occurred on socket-ID [dec]. [chars] indicates the reason for failure
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FCS-5-API_FAIL: [chars]: [chars]
Explanation An API called by FCS failed. [chars] indicates the API name failed and [chars] the reason for failure
Recommended Action If this message is seen during a cold boot, it means that the queried module came up after FCS and this case can be ignored
Error Message FCS-5-DB_NOTICE: [chars]
Explanation An error occurred during an FCS database operation. [chars] indicates the reason for the error
Recommended Action No action is required.
Error Message FCS-6-INFORMATION: [chars]
Explanation An event happend that affects FCS. [chars] indicates the event
Recommended Action No action is required.
This section contains the FEATURE-MGR messages.
Error Message FEATURE-MGR-2-FM_FSET_VMM_OP_ERROR: [chars]
Explanation The error seen at FM and VMM interaction
Recommended Action Please contact FM/VMM team
This section contains the FEX messages.
Error Message FEX-2-FEXCONFIG_ON_VPC: A green start is a must after ISSU for VPC config on FPC([hex]) for AA-FEX bringup. Please ignore if you already reloaded the switch after upgrading to version >= 7.0.3(I5)2
Explanation Green start (post ISSU) is a must to ensure programming correctness before configuring AA-FEXes
Recommended Action No action is required.
Error Message FEX-2-FEX_NOT_ONLINE_SUP_ISSU: FEX [dec] did not come online after SUP ISSU
Explanation FEX did not come online after sup ISSU
Recommended Action No action is required.
Error Message FEX-2-FEX_OFFLINE: FEX [dec] has gone OFFLINE
Explanation FEX has gone OFFLINE
Recommended Action No action is required.
Error Message FEX-2-FEX_ONLINE: FEX [dec] has come ONLINE
Explanation FEX has come ONLINE
Recommended Action No action is required.
Error Message FEX-2-NOHMS_ENV_FEX_OFFLINE: [chars]
Explanation Fex off-line
Recommended Action Show inventory
Error Message FEX-2-NOHMS_ENV_FEX_ONLINE: [chars]
Explanation Fex on-line
Recommended Action Show inventory
Error Message FEX-4-FEX_SCALING_LIMITS_REACHED: You have exceeded the advisable FEX scaling limits.
Explanation More FEX/FEX ports in the system than recommended by Cisco.
Recommended Action No action is required.
Error Message FEX-5-FEX_DISABLED: FEX Disabled
Explanation FEX Service Disabled
Recommended Action No action is required.
Error Message FEX-5-FEX_ENABLED: FEX Enabled
Explanation FEX Service Enabled
Recommended Action No action is required.
Error Message FEX-5-SATMGR_DISABLE_FAILED: Disabling of feature FEX failed. Please remove FEX related configs from interfaces
Explanation Disabling of FEX feature failed
Recommended Action No action is required.
This section contains the FIB messages.
Error Message FIB-SLOT#-0-EMERG: [chars]
Explanation Fib caused a system failure
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FIB-SLOT#-1-ALERT: [chars]
Explanation Fib caused failures in other services
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FIB-SLOT#-1-HW_RESOURCE: [chars]
Explanation Hardware resources are approaching limit.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FIB-SLOT#-1-HW_RESOURCE: [chars]
Explanation Hardware resources are approaching limit.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FIB-SLOT#-2-CRIT: [chars]
Explanation Fib encountered a catastrophic error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FIB-SLOT#-3-ERR: [chars]
Explanation Fib encountered an error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FIB-SLOT#-3-HW_FAIL: [chars]
Explanation Failed to program route into the hardware.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FIB-SLOT#-3-NO_MEM: Out of memory
Explanation Fib does not have enough memory to continue proper operation.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FIB-SLOT#-4-WARN: [chars]
Explanation Fib encountered a possible error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FIB-SLOT#-6-FIB_INFO: [chars]
Explanation Information that a corrective action was taken by FIB
Recommended Action Message is informational only
This section contains the FIPS messages.
Error Message FIPS-0-FIPS_POST_CLEANUP_FAILED: Error cleaning up keys in FIPS mode : [chars]
Explanation FIPS cleanup failed [chars]
Recommended Action No action is required.
Error Message FIPS-0-SET_FIPS_MODE_FAILED: Error when setting FIPS mode : [chars]
Explanation FIPS mode failed [chars]
Recommended Action No action is required.
Error Message FIPS-6-SET_FIPS_MODE: FIPS mode is [chars] for service [chars]
Explanation FIPS mode is changed [chars] [chars]
Recommended Action No action is required.
This section contains the FS-DAEMON messages.
Error Message FS-DAEMON-6-FSD_ENOSPC_LOGFLASH: System logflash usage has reached [dec]%. You may delete some old files on logflash to free up space
Explanation System logflash space is almost full
Recommended Action Use 'clear core archived' or 'delete' CLI to free up space on logflash
Error Message FS-DAEMON-6-FSD_ENOSPC_ROOT: System root usage has reached [dec]%. You may delete some old files from root or /var/log to free up space
Explanation System root space is almost full
Recommended Action Use 'clear core archived' or 'delete' CLI to free up space on root dir or /var/log
Error Message FS-DAEMON-6-FSD_ENOSPC_TMP: System temporary directory usage has reached [dec]%.
Explanation System /tmp space usage.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FS-DAEMON-6-FSD_REEXPORT_NFS: Re-exported NFS mounts
Explanation Exported NFS mounts are not visible in kernel and had to be reexported
Recommended Action Please use 'show system internal flash' to make sure there are no Stale NFS handles
This section contains the GLBP messages.
Error Message GLBP-2-GLBP_URIB_INIT_ERROR: [chars]
Explanation Unicast routing initialization failed and the GLBP process terminated
Recommended Action Please check syslog messages for URIB failures and rectify the problem
Error Message GLBP-3-GLBP_FEATURE_MANAGER_ERROR: [chars]: [chars]
Explanation There was a problem in GLBP interaction with feature manager.
Recommended Action Please check the reason for error using feature manager and rectify the problem
This section contains the HSRP_ENGINE messages.
Error Message HSRP_ENGINE-3-NOSOCKET: Unable to open socket
Explanation The system was unable to initialize an IP connection for the Hot Standby protocol.
Recommended Action Make sure that there is at least one interface configured to run IP.
This section contains the IKE messages.
Error Message IKE-3-IKE_PROGRAM_EXIT: [chars]
Explanation IKE process did an abnormal exit
Recommended Action No action is required.
This section contains the ILC-SPAN messages.
Error Message ILC-SPAN-3-ERROR: [chars]
Explanation Ilc_span_mgr encountered an error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
This section contains the IMP messages.
Error Message IMP-5-IMP_DISABLED: IMP Disabled
Explanation IMP Service Disabled
Recommended Action No action is required.
Error Message IMP-5-IMP_ENABLED: IMP Enabled
Explanation IMP Service nabled
Recommended Action No action is required.
This section contains the IOA_LC messages.
Error Message IOA_LC-5-IOA_DISABLED: IOA Disabled
Explanation IOA Service Disabled
Recommended Action No action is required.
Error Message IOA_LC-5-IOA_ENABLED: IOA Enabled
Explanation IOA Service nabled
Recommended Action No action is required.
This section contains the IPSEC messages.
Error Message IPSEC-5-IPSEC_DISABLED: IPSec Disabled
Explanation IPSec Disabled
Recommended Action No action is required.
Error Message IPSEC-5-IPSEC_ENABLED: IPSec Enabled
Explanation IPSec Enabled
Recommended Action No action is required.
This section contains the IPS messages.
Error Message IPS-3-ISLB_CFS_CLEAR_FAILED: [chars]
Explanation An error occurred while clearing the CFS lock. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_CFS_COMMIT_FAILED: [chars]; [chars]
Explanation An error occurred while commiting the cfs config data. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_CFS_CONFIG_FAILED: [chars]; [chars]
Explanation An error occurred while distributing the CFS config data. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_CFS_LOCK_FAILED: [chars]
Explanation An error occurred while acquiring the CFS lock. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_CFS_MERGE_ACTIVATION_FAILED: [chars]; [chars]
Explanation An error occurred while activating merged configuration. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_CFS_MERGE_CLEARED: [chars]
Explanation Merge cleared, reason: [chars]
Recommended Action No action is required.
Error Message IPS-3-ISLB_CFS_MERGE_COMMIT_FAILED: [chars]; [chars]
Explanation An error occurred while commiting the cfs merge config data. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_CFS_MERGE_CONFIG_FAILED: [chars]; [chars]
Explanation An error occurred while distributing the CFS merge config data. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_CFS_MERGE_FAILED: [chars]; [chars]
Explanation An error occurred while merging the iSLB CFS fabrics. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_CFS_MERGE_PRECOMMIT_FAILED: [chars]; [chars]
Explanation An error occurred while precommiting merge data. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_CFS_MERGE_REQ_REJECTED: [chars]
Explanation Merge requested rejected, reason: [chars]
Recommended Action No action is required.
Error Message IPS-3-ISLB_CFS_MERGING_CONFIG_DB_FAILED: [chars]; [chars]
Explanation An error occurred while merging the config data. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_CFS_PRECOMMIT_FAILED: [chars]; [chars]
Explanation An error occurred while precommiting data. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_CFS_PWWN_RESV_CLAIM_FAILED: [chars]
Explanation PWWN reservation claim failed. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_CFS_PWWN_RESV_RELEASE_FAILED: [chars]
Explanation PWWN reservation release failed. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_CFS_UNLOCK_FAILED: [chars]
Explanation An error occurred while releasing the CFS lock. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_CFS_VRRP_DIST_FAILED: [chars]
Explanation An error occurred while distributing the VRRP CFS runtime data. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-5-IPS_IPACL_LOG_MSG: [chars]
Explanation Details of the packet dropped due to ACLs
Recommended Action No action is required.
This section contains the LACP messages.
Error Message LACP-3-GENERAL_ERROR: [chars]
Explanation General error
Recommended Action No action is required.
Error Message LACP-5-LACP_DISABLED: LACP Disabled
Explanation LACP Service Disabled
Recommended Action No action is required.
Error Message LACP-5-LACP_ENABLED: LACP Enabled
Explanation LACP Service Enabled
Recommended Action No action is required.
This section contains the LC-SPAN messages.
Error Message LC-SPAN-3-ERROR: [chars]
Explanation Lc_span_mgr encountered an error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
This section contains the LDAP messages.
Error Message LDAP-3-LDAP_ERROR_MESSAGE: [chars]
Explanation LDAP Error Message
Recommended Action No action is required.
Error Message LDAP-5-LDAP_MONITOR_STATUS: [chars] [chars]
Explanation Notifying Ldap server monitor status change
Recommended Action No action is required.
Error Message LDAP-5-LDAP_SERVER_STATUS: [chars] server [chars] with port [dec] status has changed from [chars] to [chars]. Server was in previous-state for [chars], and total dead time of the server is [chars]
Explanation Notifying Ldap server status change
Recommended Action No action is required.
Error Message LDAP-6-LDAP_MESSAGE: [chars]
Explanation LDAP Message
Recommended Action No action is required.
This section contains the LDP messages.
Error Message LDP-5-LDP_DISABLED: LDP Disabled
Explanation MPLS_LDP Service Disabled
Recommended Action No action is required.
Error Message LDP-5-LDP_ENABLED: LDP Enabled
Explanation MPLS_LDP Service nabled
Recommended Action No action is required.
This section contains the LICMGR messages.
Error Message LICMGR-3-LOG_LIC_SERVER_DOWN: License Server Down [dec]
Explanation A connection to the license server was lost.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message LICMGR-6-LOG_LIC_FEATURE_CLEARED: Cleared [dec] license(s) for feature [chars].
Explanation Uninstalled [dec] license(s) for feature [chars].
Recommended Action Use the 'show license usage' command to verify this license feature removal.
Error Message LICMGR-6-LOG_LIC_FEATURE_INSTALLED: Installed [dec] license(s) for feature [chars].
Explanation Installed [dec] license(s) for feature [chars].
Recommended Action Use the 'show license usage' command to verify this license feature installation.
Error Message LICMGR-6-LOG_LIC_LICENSE_CLEARED: Cleared license file [chars].
Explanation Uninstalled the named license file.
Recommended Action Use the 'show license' command to verify this license removal.
Error Message LICMGR-6-LOG_LIC_LICENSE_INSTALLED: Installed license file [chars].
Explanation Installed the named license file.
Recommended Action Use the 'show license' command to verify this license installation.
This section contains the LLDP messages.
Error Message LLDP-5-LLDP_DISABLED: LLDP Disabled
Explanation LLDP Service Disabled
Recommended Action No action is required.
Error Message LLDP-5-LLDP_ENABLED: LLDP Enabled
Explanation LLDP Service Enabled
Recommended Action No action is required.
This section contains the MCAST messages.
Error Message MCAST-2-SHUTDOWN: Process shutting down: [chars]
Explanation Mcast is shutting down
Recommended Action The action depends on the situation. The multicast process can shut down gracefully because of a system restart (in which case no action needs to take place) or because of a failure. The message associated with the syslog should be self explanatory to understand the reason for the shutdown. If the process is able to restart properly, there is no immediate harm for the system stability and the suggested action is to report the syslog event together with an explanation of the operations most recently performed on the system.
Error Message MCAST-4-ERROR: [chars]
Explanation Mcast encountered a generic error
Recommended Action No action is required.
Error Message MCAST-5-START: Process has been started
Explanation Mcast has been started
Recommended Action No action is required.
This section contains the MCECTEST messages.
Error Message MCECTEST-3-ASSERTION_FAILED: [chars]
Explanation MCECTEST has hit an assert condition at file [chars]
Recommended Action No action is required.
Error Message MCECTEST-3-INIT_FAIL: [chars]
Explanation MCECTEST Initialization failed. due to [chars]
Recommended Action No action is required.
Error Message MCECTEST-3-INTERNAL_ERR: [chars]
Explanation MCECTEST encountered an internal error due to [chars]
Recommended Action No action is required.
Error Message MCECTEST-3-MTS_ERR: [chars]
Explanation MCECTEST encountered an MTS error due to [chars]
Recommended Action No action is required.
Error Message MCECTEST-5-MCECTEST_DISABLED: MCECTEST Disabled
Explanation MCECTEST Service Disabled
Recommended Action No action is required.
Error Message MCECTEST-5-MCECTEST_ENABLED: MCECTEST Enabled
Explanation MCECTEST Service enabled
Recommended Action No action is required.
Error Message MCECTEST-6-INTERNAL_INFO: [chars]
Explanation MCECTEST got an internal info [chars]
Recommended Action No action is required.
This section contains the MCM messages.
Error Message MCM-2-MCM_CRITICAL_ERROR: Internal Critical Error
Explanation Some critical error
Recommended Action No action is required.
Error Message MCM-5-MCM_SDB_UPDATE_FAILED: sdb update failed with ret_val [dec]
Explanation SDB updated failed for MCM
Recommended Action No action is required.
This section contains the MONITORC messages.
Error Message MONITORC-SLOT#-3-MONITORC_FAILED: MONITORC failure: [chars]
Explanation Span session programming failed with no H/W resource
Recommended Action No DDTS.
This section contains the MPLS_OAM messages.
Error Message MPLS_OAM-5-LSPV_DISABLED: LSPV Disabled
Explanation MPLS_LSPV Service Disabled
Recommended Action No action is required.
Error Message MPLS_OAM-5-LSPV_ENABLED: LSPV Enabled
Explanation MPLS_LSPV Service nabled
Recommended Action No action is required.
This section contains the MPLS_STATIC messages.
Error Message MPLS_STATIC-5-MPLS_STATIC_DISABLED: MPLS_STATIC Disabled
Explanation MPLS_STATIC Service Disabled
Recommended Action No action is required.
Error Message MPLS_STATIC-5-MPLS_STATIC_ENABLED: MPLS_STATIC Enabled
Explanation MPLS_STATIC Service enabled
Recommended Action No action is required.
This section contains the NAT messages.
Error Message NAT-2-HW_PROG_FAILED: Hardware programming for NAT failed:[chars]([dec])
Explanation NAT software encountered an error while programming the hardware to do NAT translation
Recommended Action No action is required.
Error Message NAT-5-NAT_LOG_DISABLED: [chars] license not installed or expired
Explanation NAT needs license to run
Recommended Action No action is required.
Error Message NAT-5-NAT_LOG_ENABLED: [chars] license installed
Explanation NAT needs license to run
Recommended Action No action is required.
This section contains the NEUTRON_USD messages.
Error Message NEUTRON_USD-0-I2C_DEV_INIT_FAIL: [chars]
Explanation I2C device initialaisation failure
Recommended Action No action is required.
Error Message NEUTRON_USD-0-RETIMER_INIT_FAIL_SFP: [chars]
Explanation Retimer initialisation failure for SFP
Recommended Action No action is required.
Error Message NEUTRON_USD-0-RETIMER_INIT_FAIL_TRIDENT: [chars]
Explanation Retimer initialisation failure for Trident
Recommended Action No action is required.
Error Message NEUTRON_USD-0-RETIMER_INIT_FAIL: [chars]
Explanation Retimer initialisation failure
Recommended Action No action is required.
Error Message NEUTRON_USD-0-USD_DRV_INIT_FAIL: [chars]
Explanation USD driver init failure
Recommended Action No action is required.
Error Message NEUTRON_USD-2-WRONG_MICROCODE: [chars]
Explanation Wrong Neutron microcode version
Recommended Action No action is required.
Error Message NEUTRON_USD-3-NULL_PORT_PTR: [chars]
Explanation Null port pointer
Recommended Action No action is required.
Error Message NEUTRON_USD-6-BYPASS_NEUTRON: [chars]
Explanation Bypassing Neutron
Recommended Action No action is required.
Error Message NEUTRON_USD-6-NEUTRON_CLN: [chars]
Explanation Set neutron chip for CLN
Recommended Action No action is required.
Error Message NEUTRON_USD-6-NEUTRON_QI: [chars]
Explanation Set neutron chip for QI
Recommended Action No action is required.
This section contains the NFP messages.
Error Message NFP-SLOT#-2-NF_ACL_ERR: [chars]([dec]): acl error. [chars]
Explanation Acl error
Recommended Action No DDTS.
Error Message NFP-SLOT#-2-NF_DDB_ERR: [chars]([dec]): ddb error.[chars] [hex]
Explanation Ddb error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message NFP-SLOT#-2-NF_ERR: [chars]([dec]): nfp error. [chars]
Explanation Nfp error occured
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message NFP-SLOT#-2-NF_FIB_ERR: [chars]([dec]): fib error. [chars]
Explanation Fib error
Recommended Action No DDTS.
Error Message NFP-SLOT#-2-NF_NDE_ERR: [chars]([dec]): nde error. [chars]
Explanation Nde error
Recommended Action No DDTS.
Error Message NFP-SLOT#-2-NF_NFM_ERR: [chars]([dec]): nfm error. [chars]
Explanation Nfm error
Recommended Action No DDTS.
Error Message NFP-SLOT#-2-NF_QOS_ERR: [chars]([dec]): qos error. [chars]
Explanation Qos error
Recommended Action No DDTS.
Error Message NFP-SLOT#-5-NF_INFO: [chars]
Explanation Info
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
This section contains the NGOAM messages.
Error Message NGOAM-4-ENTER_SESSION: [chars]
Explanation Notification of Looback response received for a session.
Recommended Action No action is required.
Error Message NGOAM-4-EXIT_SESSION: [chars]
Explanation Notification of connectivity loss for a Looback session.
Recommended Action No action is required.
Error Message NGOAM-4-SESSION_ERROR: [chars]
Explanation Notification of connectiviy issue for oam packet
Recommended Action No action is required.
This section contains the NPV messages.
Error Message NPV-3-ACL_UPDATE_FAILED: [chars]
Explanation ACL update request initiated by the NPV process has failed
Recommended Action No action is required.
Error Message NPV-3-CLEAR_FAILED: [chars]
Explanation An error occurred while clearing the lock. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message NPV-3-COMMIT_FAILED: [chars]
Explanation An error occurred while committing configuration. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message NPV-3-COMMIT_PARTIALLY_FAILED: [chars]
Explanation An error occurred while committing configuration. Configuration could not be committed on some switches. The reason for the failure : [chars]. Configuration can be inconsistent in the fabric.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message NPV-3-COMMIT_REJECTED: [chars]
Explanation Commit request received from remote switch is rejected. The reason for the failure: [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message NPV-3-FC2_SEND_FAILED: [chars]
Explanation NPV process could send an FC2 message.
Recommended Action No action is required.
Error Message NPV-3-F_RJT_SENT: [chars]
Explanation NPV process sent an F_RJT frame.
Recommended Action No action is required.
Error Message NPV-3-INTERNAL_ERROR: Internal error: [chars]
Explanation NPV process encountered a general error, one that does not fall in any of the categories. [chars] describes the error and its context.
Recommended Action No action is required.
Error Message NPV-3-LCP_PROGRAMMING_FAILED: [chars]
Explanation LCP programming request initiated by the NPV process has failed
Recommended Action No action is required.
Error Message NPV-3-LOCK_FAILED: [chars]
Explanation An error occurred while acquiring the lock. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message NPV-3-LS_RJT_RCVD: [chars]
Explanation NPV process received an LS_RJT frame.
Recommended Action No action is required.
Error Message NPV-3-LS_RJT_SENT: [chars]
Explanation NPV process sent an LS_RJT frame.
Recommended Action No action is required.
Error Message NPV-3-MALLOC_FAILED: [chars]
Explanation NPV process could not allocate memory
Recommended Action No action is required.
Error Message NPV-3-MERGE_ACTIVATION_FAILED: [chars]
Explanation An error occurred while activating merged configuration. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message NPV-3-MERGE_FAILED: [chars]
Explanation An error occurred while merging configuration. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message NPV-3-MTS_SEND_FAILED: [chars]
Explanation NPV process could not send an MTS message.
Recommended Action No action is required.
Error Message NPV-3-NPIV_DISABLE_FAILED: [chars]
Explanation NPIV feature could not be disabled.
Recommended Action No action is required.
Error Message NPV-3-NPIV_NOT_SUPPORTED: [chars]
Explanation Nexus 9000 platform supports FCOE-NPV only. So, NPIV feature has no meaning in this platform
Recommended Action No action is required.
Error Message NPV-3-NPV_UPLINK_UNSTABLE: [chars]
Explanation Atleast one of the external interface is unstable. Loadbalancing across uplink requires stable links
Recommended Action No action is required.
Error Message NPV-3-PORT_BRINGUP_FAILED: [chars]
Explanation NPV process has failed to bringup the port
Recommended Action No action is required.
Error Message NPV-3-PORT_REINIT_FAILED: [chars]
Explanation Port reinit request initiated by the NPV process has failed
Recommended Action No action is required.
Error Message NPV-3-UNLOCK_FAILED: [chars]
Explanation An error occurred while releasing the lock. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message NPV-5-FRAME_DISCARDED: [chars]
Explanation NPV process discarded an FC2 frame.
Recommended Action No action is required.
Error Message NPV-5-UNEXPECTED_EVENT: [chars]
Explanation NPV process has received an unexpected event in the current state.
Recommended Action No action is required.
Error Message NPV-6-ABTS_SENT: [chars]
Explanation NPV process sent an ABTS frame.
Recommended Action No action is required.
Error Message NPV-6-ELS_CMD_SENT_TO_CORE: [chars]
Explanation NPV process sent an ELS frame to the core switch.
Recommended Action No action is required.
Error Message NPV-6-ELS_CMD_SENT_TO_SRV: [chars]
Explanation NPV process sent an ELS frame to the server.
Recommended Action No action is required.
Error Message NPV-6-EXT_IF_SELECTED: [chars]
Explanation NPV process has selected an external interface to forward either all frames received on a server interface or frames received from a specific port WWN.
Recommended Action No action is required.
Error Message NPV-6-FABRIC_PROXY_LOGO_SENT: [chars]
Explanation NPV process sent a LOGO frame to the device as the corresponding external interface went down.
Recommended Action No action is required.
Error Message NPV-6-FDISC_RCVD: [chars]
Explanation NPV process received an FDISC frame.
Recommended Action No action is required.
Error Message NPV-6-FDISC_SENT: [chars]
Explanation NPV process sent an FDISC frame to the core switch.
Recommended Action No action is required.
Error Message NPV-6-FLOGI_RCVD: [chars]
Explanation NPV process received an FLOGI frame.
Recommended Action No action is required.
Error Message NPV-6-INTERNAL_FLOGI_SENT: [chars]
Explanation NPV process sent an internal FLOGI frame to the core switch on an external interface.
Recommended Action No action is required.
Error Message NPV-6-LOGO_RCVD: [chars]
Explanation NPV process received a LOGO frame.
Recommended Action No action is required.
Error Message NPV-6-LOGO_SENT: [chars]
Explanation NPV process sent a LOGO frame.
Recommended Action No action is required.
Error Message NPV-6-LS_ACC_RCVD: [chars]
Explanation NPV process received an LS_ACC frame.
Recommended Action No action is required.
Error Message NPV-6-LS_ACC_SENT: [chars]
Explanation NPV process sent an LS_ACC frame.
Recommended Action No action is required.
Error Message NPV-6-MTS_NOTIF_RCVD: [chars]
Explanation NPV process received an MTS notification.
Recommended Action No action is required.
Error Message NPV-6-MTS_NOTIF_SENT: [chars]
Explanation NPV process sent an MTS notification.
Recommended Action No action is required.
Error Message NPV-6-MTS_REQ_RCVD: [chars]
Explanation NPV process received an MTS request.
Recommended Action No action is required.
Error Message NPV-6-MTS_REQ_SENT: [chars]
Explanation NPV process sent an MTS request.
Recommended Action No action is required.
Error Message NPV-6-MTS_RESP_RCVD: [chars]
Explanation NPV process received an MTS response.
Recommended Action No action is required.
Error Message NPV-6-MTS_RESP_SENT: [chars]
Explanation NPV process sent an MTS response.
Recommended Action No action is required.
Error Message NPV-6-NPIV_DISABLED: [chars]
Explanation NPIV feature has been disabled.
Recommended Action No action is required.
Error Message NPV-6-NPIV_ENABLED: [chars]
Explanation NPIV feature has been enabled.
Recommended Action No action is required.
Error Message NPV-6-NPV_ENABLE_DISABLE_IN_PROGRESS: [chars]
Explanation NPV feature enable/disable is in progress. This syslog is printed at the beginning of various significant phases.
Recommended Action No action is required.
Error Message NPV-6-SERVER_PROXY_LOGO_SENT: [chars]
Explanation NPV process sent a LOGO frame to the core switch as the server interface went down.
Recommended Action No action is required.
Error Message NPV-7-CFS_REQ_RCVD: [chars]
Explanation CFS request is received. The WWN of the switch originated this request and the rr-token of the request are provided in the syslog message.
Recommended Action No action is required.
Error Message NPV-7-CFS_RESP_SENT: [chars]
Explanation CFS response is sent. The rr-token of the corresponding request and the status are provided in the syslog message
Recommended Action No action is required.
This section contains the NSUSD messages.
Error Message NSUSD-6-NSAUSD_DEBUG_MSG: [chars]
Explanation Debug log message
Recommended Action No action is required.
This section contains the NTP messages.
Error Message NTP-2-NTP_SYSLOG_CRIT_ERR: : [chars]
Explanation NTP syslog Critial Error : [chars].
Recommended Action No action is required.
Error Message NTP-2-NTP_SYSLOG_INIT_FAIL: : [chars] [chars]
Explanation NTP Initialization Failed: [chars] [chars].
Recommended Action No action is required.
Error Message NTP-2-NTP_SYSLOG_NO_RESP_FROM_LC: from LC[dec] for [chars]
Explanation NTP did not receive response from the linecard for the request sent.
Recommended Action No action is required.
Error Message NTP-3-NTP_SYSLOG_ALLOC_FAIL: : [chars]
Explanation NTP syslog allocation failed : [chars].
Recommended Action No action is required.
Error Message NTP-3-NTP_SYSLOG_ERR_EXT: : [chars] [chars]
Explanation NTP syslog Error Exit : [chars] [dec].
Recommended Action No action is required.
Error Message NTP-3-NTP_SYSLOG_ERR: : [chars]
Explanation NTP syslog Error : [chars].
Recommended Action No action is required.
Error Message NTP-3-NTP_SYSLOG_MTS_ERR: : [chars]
Explanation NTP MTS Error : [chars].
Recommended Action No action is required.
Error Message NTP-6-NTP_SYSLOG_CREATED: : [chars]; Slot No: [dec]
Explanation NTP syslog created : [chars] [chars].
Recommended Action No action is required.
Error Message NTP-6-NTP_SYSLOG_EXIT: : [chars]
Explanation NTP syslog Exit : [chars].
Recommended Action No action is required.
Error Message NTP-6-NTP_SYSLOG_LOGGING: : [chars]
Explanation NTP logging : [chars].
Recommended Action No action is required.
Error Message NTP-6-NTP_SYSLOG_WARN: : [chars]
Explanation NTP syslog Warning : [chars].
Recommended Action No action is required.
This section contains the OBFL messages.
Error Message OBFL-3-ERROR: [chars]
Explanation Obfl_encountered an error
Recommended Action No action is required.
This section contains the ONEP messages.
Error Message ONEP-6-HISTORY: [chars]
Explanation This syslog message is used to display onePK history messages when the 'history syslog' onep command is enabled.
Recommended Action LOG_STD_SH_CMD_ACTION( No action is required. Use 'no history syslog' at the onep configuration prompt to turn off this logging if desired.)
This section contains the OTM messages.
Error Message OTM-2-OTM_EEM_FAIL: OTM failed to register with EEM
Explanation OTM process failed to register with eem, exiting now
Recommended Action No action is required.
Error Message OTM-3-OTM_ERROR: [chars] [chars]
Explanation [chars1][chars2]
Recommended Action No action is required.
Error Message OTM-5-OTM_OBJ_ADD: : Tracking object [dec] configured, status of the object [chars]
Explanation Tracking Object [dec] configured, status of the object [chars]
Recommended Action No action is required.
Error Message OTM-6-OTM_EXITED: OTM process exited
Explanation OTM process is terminated
Recommended Action No action is required.
Error Message OTM-6-OTM_OBJ_REM: : Tracking object [dec] removed
Explanation Tracking Object [dec] removed
Recommended Action No action is required.
Error Message OTM-6-OTM_STARTED: OTM process started
Explanation OTM process is up and running
Recommended Action No action is required.
Error Message OTM-6-OTM_TRACK_START: Client started tracking object [dec]
Explanation Client has started tracking object [dec]
Recommended Action No action is required.
Error Message OTM-6-OTM_TRACK_STOP: Client stopped tracking object [dec]
Explanation Client has stopped tracking object [dec]
Recommended Action No action is required.
This section contains the PATCH-INSTALLER messages.
Error Message PATCH-INSTALLER-3-PATCH_INSTALLER_OP_FAILED: Package Install operation: [chars] , operation ID: [dec], failed with error: [dec] ([chars]) at: [chars]
Explanation Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Recommended Action Patch_installer
This section contains the PIXM messages.
Error Message PIXM-2-PIXM_SYSLOG_MESSAGE_TYPE_CRIT: [chars]
Explanation PIXM has encountered a critical error
Recommended Action Please collect PIXM tech support using 'show tech pixm-all' and 'show tech pixmc-all'
Error Message PIXM-3-PIXM_SYSLOG_MESSAGE_TYPE_ERR: [chars]
Explanation PIXM has encountered a error
Recommended Action Please collect PIXM tech support using 'show tech pixm-all' and 'show tech pixmc-all'
Error Message PIXM-4-PIXM_SYSLOG_MESSAGE_TYPE_WARNING: [chars]
Explanation PIXM has encountered a warning-level error
Recommended Action Please collect PIXM tech support using 'show tech pixm-all' and 'show tech pixmc-all'
Error Message PIXM-7-PIXM_SYSLOG_MESSAGE_TYPE_DEBUG: [chars]
Explanation This is a debug output from PIXM
Recommended Action Please collect PIXM tech support using 'show tech pixm-all' and 'show tech pixmc-all'
This section contains the PLATFORM messages.
Error Message PLATFORM-0-FAIL_REMOVED: Fan module removed. Fan[dec] has been absent for [dec] seconds
Explanation Fan module is removed. This could lead to temperature alarms.
Recommended Action Replace the fan module ASAP.
Error Message PLATFORM-0-PFM_EMERGENCY: [chars]
Explanation Platform Emergency
Recommended Action No action is required.
Error Message PLATFORM-0-SYS_RESET: [chars] System shutdown in [dec] seconds
Explanation System shutdown in [decimal digit] seconds.
Recommended Action Please perform a 'show env temperature' to collect more information.
Error Message PLATFORM-1-FABRIC_SWITCH_FAN_FAIL: Less than 4 required fans operating.
Explanation Fan module has failed leaving less than 4 total fans operating. Fan needs to be replaced. This can lead to overheating and temperature alarms.
Recommended Action Please perform a 'show platform internal info' to collect more information.
Error Message PLATFORM-1-FAN_FAIL: Fan module Failed
Explanation Fan module has failed and needs to be replaced. This can lead to overheating and temperature alarms.
Recommended Action Please perform a 'show platform internal info' to collect more information.
Error Message PLATFORM-1-PFM_ALERT: [chars]
Explanation Platform Alert
Recommended Action No action is required.
Error Message PLATFORM-1-PS_SINGLE_INPUT: Both power inputs are connected for Power supplies, remove single-input configuration for optimal power usage
Explanation Current power supply redundancy mode may not be optimal
Recommended Action Please perform a 'show environment power' and 'show platform internal info' to collect more information.
Error Message PLATFORM-2-9134_FAN_FAIL: Fan module [dec] Failed
Explanation Fan module has failed and needs to be replaced. This can lead to overheating and temperature alarms.
Recommended Action Please perform a 'show platform internal info' to collect more information.
Error Message PLATFORM-2-9134_FAN_OK: Fan module [dec] ok
Explanation Fan module is ok
Recommended Action No action is required.
Error Message PLATFORM-2-CASA_FAN_FAIL: Fan module [dec] Failed
Explanation Fan module has failed and needs to be replaced. This can lead to overheating and temperature alarms.
Recommended Action Please perform a 'show platform internal info' to collect more information.
Error Message PLATFORM-2-CASA_FAN_OK: Fan module [dec] ok
Explanation Fan module is ok
Recommended Action No action is required.
Error Message PLATFORM-2-FANLET_FAN_FAIL: Failed Fanlets for Fan [dec] ([chars] fan) : [chars]
Explanation The specified fanlets have failed. This can lead to overheating and temperature alarms.
Recommended Action Please perform a 'show platform internal info' to collect more information.
Error Message PLATFORM-2-FANMOD_FAN_FAIL: Fan module [dec] ([chars] fan) Failed/Removed
Explanation Fan module has failed and needs to be replaced. This can lead to overheating and temperature alarms.
Recommended Action Please perform a 'show platform internal info' to collect more information.
Error Message PLATFORM-2-FANMOD_FAN_OK: Fan module [dec] ([chars] fan) ok
Explanation Fan module is ok
Recommended Action No action is required.
Error Message PLATFORM-2-FAN_OK: Fan module ok
Explanation Fan module is ok
Recommended Action No action is required.
Error Message PLATFORM-2-FAN_REMOVED: Fan module [dec] (Serial number [chars]) [chars] removed
Explanation Fan module is removed
Recommended Action No action is required.
Error Message PLATFORM-2-PFM_CRITICAL: [chars]
Explanation Platform Critical
Recommended Action No action is required.
Error Message PLATFORM-2-PFM_PREP_DEEP_SLEEP: Supervisor module in slot [dec] preparing to enter deep sleep mode
Explanation Deep sleep mode initiated by the Connectivity Management Processor (CMP) for this supervisor
Recommended Action No action is required.
Error Message PLATFORM-2-PS_CAPACITY_CHANGE: Power supply PS[dec] changed its capacity. possibly due to On/Off or power cable removal/insertion (Serial number [chars])
Explanation Detected power supply capacity change.
Recommended Action Please refer to power supply document on increasing decreasing power supply capacity, configuring power supplies, etc. Please perform 'show environment power' and 'show platform internal info' to collect more information.
Error Message PLATFORM-2-PS_CAPACITY_DIFFER: Detected power supplies with differing capacity. It is recommended to have same capacity for both powersupplies otherwise it may cause service disruptions
Explanation Detected a power supply that has differing capacity than an the otherpower supply.
Recommended Action Please refer to power supply document on increasing decreasing power supply capacity, configuring power supplies, etc. Please perform 'show environment power' and 'show platform internal info' to collect more information.
Error Message PLATFORM-2-PS_FAIL: Power supply [dec] failed or shut down (Serial number [chars])
Explanation Power Supply has failed or has been shutdown
Recommended Action Please perform a 'show environment power' and 'show platform internal info' to collect more information. Please refer to power supply document on increasing decreasing power supply capacity, configuring power supplies, etc.
Error Message PLATFORM-2-PS_FANFAIL: Fan in Power supply [dec] failed
Explanation Fan module in the Power Supply has failed
Recommended Action Please perform a 'show environment power' and 'show platform internal info' to collect more information.
Error Message PLATFORM-2-PS_FANOK: Fan in Power supply [dec] ok
Explanation Fan module in the Power Supply is ok.
Recommended Action No action is required.
Error Message PLATFORM-2-PS_MISMATCH: Detected power supply [chars]. This reduces the redundant power available to the system and can cause service disruptions (Serial number [chars])
Explanation Detected a new power supply that has reduced capacity than an existing power supply.
Recommended Action Please refer to power supply document on increasing decreasing power supply capacity, configuring power supplies, etc. Please perform 'show environment power' and 'show platform internal info' to collect more information.
Error Message PLATFORM-2-PS_OK: Power supply [dec] ok (Serial number [chars])
Explanation Power Supply is ok.
Recommended Action No action is required.
Error Message PLATFORM-2-PS_RED_MODE_CHG: Power supply operational redundancy mode changed to [chars]
Explanation Power supply redundancy mode changed notification
Recommended Action Please perform a 'show environment power' and 'show platform internal info' to collect more information.
Error Message PLATFORM-2-PS_REMOVE_LAST: Unexpected removal of last power supply [dec]. (Serial number [chars])
Explanation Unexpected removal the only power supply in the system.
Recommended Action Power supply unit may be faulty. Contact CISCO to replace the unit.
Error Message PLATFORM-2-PS_UNKNOWN: Detected an unknown power supply [dec] for CISCO Multilayer Switch (Serial number [chars])
Explanation Unable to determine power supply type. Default power supply types will be assumed.
Recommended Action Please refer to power supply document on increasing decreasing power supply capacity, configuring power supplies, etc.
Error Message PLATFORM-2-PS_UNSUPPORTED: Detected an unsupported power supply [dec] [chars] for CISCO Multilayer Switch (Serial number [chars])
Explanation This power supply is not supported for the CISCO Multilayer Switches.
Recommended Action Please refer to power supply document on increasing decreasing power supply capacity, configuring power supplies, etc.
Error Message PLATFORM-3-PFM_ERROR: [chars]
Explanation Platform Error
Recommended Action No action is required.
Error Message PLATFORM-4-PFM_WARNING: [chars]
Explanation Platform Warning
Recommended Action No action is required.
Error Message PLATFORM-5-FAN_DETECT: Fan module [dec] (Serial number [chars]) [chars] detected
Explanation Fan module is detected
Recommended Action No action is required.
Error Message PLATFORM-5-FAN_STATUS: Fan module [dec] (Serial number [chars]) [chars] current-status is [chars]
Explanation Fan module changed status
Recommended Action No action is required.
Error Message PLATFORM-5-FEX_FAN_DETECT: Fex [dec] Fan Module [dec] detected
Explanation Fex Fan module is detected
Recommended Action No action is required.
Error Message PLATFORM-5-FEX_FAN_REMOVE: Fex [dec] Fan Module [dec] removed
Explanation Fex Fan module is removed
Recommended Action No action is required.
Error Message PLATFORM-5-FEX_PS_FOUND: Fex [dec] Power Supply [dec] found (Serial number [chars])
Explanation Fex power supply is found
Recommended Action No action is required.
Error Message PLATFORM-5-FEX_PS_REMOVE: Fex [dec] Power Supply [dec] removed (Serial number [chars])
Explanation Fex power supply is removed
Recommended Action No action is required.
Error Message PLATFORM-5-PFM_NOTICE: [chars]
Explanation Platform Notice
Recommended Action No action is required.
Error Message PLATFORM-6-PFM_INFO: [chars]
Explanation Platform Info
Recommended Action No action is required.
Error Message PLATFORM-7-PFM_CLOCK_UPD_FAIL: Clock update failed due to context-switch delay of [dec] msec
Explanation System shutdown in [decimal digit] seconds.
Recommended Action Please perform a 'show env temperature' to collect more information.
This section contains the PLOG_SUP messages.
Error Message PLOG_SUP-4-PLOG_SUP_EXIT: Persistent Logger encountered an error [dec].
Explanation Persistent Logger encountered an error
Recommended Action No action is required.
This section contains the PLOG messages.
Error Message PLOG-4-PLOG_LC_EXIT: Persistent Logger encountered an error [dec]
Explanation Persistent Logger encountered an error
Recommended Action No action is required.
This section contains the POAP messages.
Error Message POAP-2-POAP_DHCP_DISCOVER_START: [chars] - POAP DHCP Discover phase started
Explanation POAP DHCP Discover phase started
Recommended Action No action is required.
Error Message POAP-2-POAP_FAILURE_READ_MODINFO: [chars] - Failure to read module info
Explanation POAP failure to read module info
Recommended Action No action is required.
Error Message POAP-2-POAP_FAILURE: [chars] - [chars]
Explanation POAP failure
Recommended Action No action is required.
Error Message POAP-2-POAP_INFO: [chars] - [chars]
Explanation POAP Info
Recommended Action No action is required.
Error Message POAP-2-POAP_INITED: [chars] - POAP process initialized
Explanation POAP process initialized
Recommended Action No action is required.
Error Message POAP-2-POAP_RELOAD_DEVICE: [chars] - Reload device
Explanation POAP reload device.
Recommended Action No action is required.
Error Message POAP-2-POAP_SCRIPT_DOWNLOADED: [chars] - Successfully downloaded POAP script file
Explanation Successfully downloaded POAP script file
Recommended Action No action is required.
Error Message POAP-2-POAP_SCRIPT_STARTED_MD5_NOT_VALIDATED: [chars] - POAP script execution started(MD5 not validated)
Explanation POAP script execution started(MD5 not validated)
Recommended Action No action is required.
Error Message POAP-2-POAP_SCRIPT_STARTED_MD5_VALIDATED: [chars] - POAP script execution started(MD5 validated)
Explanation POAP script execution started(MD5 validated)
Recommended Action No action is required.
Error Message POAP-2-POAP_SCRIPT_STARTED_MD5_VALIDATION_FAIL: [chars] - POAP boot file validation failed
Explanation POAP boot file validation failed.
Recommended Action No action is required.
Error Message POAP-5-POAP_DISABLED: [chars] - POAP Disabled
Explanation POAP Service Disabled
Recommended Action No action is required.
Error Message POAP-5-POAP_ENABLED: [chars] - POAP Enabled
Explanation POAP Service nabled
Recommended Action No action is required.
This section contains the PONG messages.
Error Message PONG-5-PONG_DISABLED: Pong Manager disabled
Explanation Pong Service Enabled
Recommended Action No action is required.
Error Message PONG-5-PONG_ENABLED: Pong Manager enabled
Explanation Pong Service Enabled
Recommended Action No action is required.
Error Message PONG-5-PONG_INJECTED: Pong packet injected
Explanation Pong packet injected
Recommended Action No action is required.
This section contains the PORT-CHANNEL messages.
Error Message PORT-CHANNEL-3-GENERAL_ERROR: [chars]
Explanation General error
Recommended Action No action is required.
Error Message PORT-CHANNEL-4-PORT_CFG_DELETED: [chars] removed from [chars]
Explanation Port is removed from a port-channel because different module was inserted or module config purged
Recommended Action You lost some ports from port-channel, check if you want to add ports in the new module to the same port-channel.
Error Message PORT-CHANNEL-4-RACE_WARN: [chars]
Explanation Warning of possible race condition
Recommended Action No action is required.
Error Message PORT-CHANNEL-5-CREATED: [chars] created
Explanation A port-channel is created
Recommended Action No action is required.
Error Message PORT-CHANNEL-5-DELETED: [chars] deleted
Explanation A port-channel is deleted
Recommended Action No action is required.
Error Message PORT-CHANNEL-5-PORT_ADDED: [chars] added to [chars]
Explanation Ports are added to a port-channel
Recommended Action No action is required.
Error Message PORT-CHANNEL-5-PORT_REMOVED: [chars] removed from [chars]
Explanation Ports are removed from a port-channel
Recommended Action No action is required.
This section contains the PORT-SECURITY messages.
Error Message PORT-SECURITY-2-INIT_FAILURE: : [chars]
Explanation FC Management initialisation has failed due to [chars].
Recommended Action No action is required.
Error Message PORT-SECURITY-3-BINDING_CONFLICT: [chars]
Explanation An already logged in device is in conflict with the PSM active binding configurations. [chars] indicates the WWN of the login entity, interface
Recommended Action For port-security, the auto-learn feature can be used with activation to prevent this. This violating device or switch will be logged out
Error Message PORT-SECURITY-3-BINDING_VIOLATION: [chars]
Explanation A login happend that violates PSM binding configurations [chars] indicates the WWN of the login entity
Recommended Action Only entries in the activated database of PSM can login. Change the config and activate it again
Error Message PORT-SECURITY-3-CFS_NOTIF_ERR: [chars]
Explanation An error occurred during the processing of a CFS notification. [chars] indicates the actual cause for the error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message PORT-SECURITY-3-DB_ERR: [chars]
Explanation An error occurred during an PSM database operation. [chars] indicates the reason for the error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message PORT-SECURITY-3-EFMD_FC2_OPER_FAILED: [chars]
Explanation EFMD fc2 operation failed
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message PORT-SECURITY-3-EFMD_INIT_FAILED: [chars]
Explanation EFMD init failed
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message PORT-SECURITY-3-EFMD_MERGE_UNKNOWN_FORMAT: [chars]
Explanation Received a corrupted EFMD Request Packet
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message PORT-SECURITY-3-FCID_CONV_ERR: : [chars]
Explanation FC Management pwwn to fcid conversion has failed due to [chars].
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message PORT-SECURITY-3-INIT_FAIL: [chars]
Explanation An error happened during PSM Initialization. [chars] indicates the reason for failure
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message PORT-SECURITY-3-LEARNT_BINDING_CONFLICT: [chars]
Explanation An already logged in device that is learnt during activation is in conflict with the PSM active binding configurations. [chars] indicates the WWN of the login entity, interface
Recommended Action Copy the active-db to config-db and reactivate. Not doing so could result in unexpected login rejects later on that interface.
Error Message PORT-SECURITY-3-MAX_LIMIT_CROSSED: [chars]
Explanation MGMT_SEC: Max Limit for the config has exceeded.[chars]
Recommended Action No action is required.
Error Message PORT-SECURITY-3-MS_DB_ERR: : [chars]
Explanation FC Management db operation has failed due to [chars].
Recommended Action No action is required.
Error Message PORT-SECURITY-3-MS_DISABLE_ERR: [chars]
Explanation An error occurred during an FC Management disable operation. [chars] indicates the operation that caused the error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message PORT-SECURITY-3-MS_ENABLE_ERR: [chars]
Explanation An error occurred during an FC Management enable operation. [chars] indicates the operation that caused the error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message PORT-SECURITY-3-MTS_ERR: [chars]
Explanation An error occurred in processing of an MTS message. [chars] indicates the error that occurred
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message PORT-SECURITY-3-PSS_ERR: [chars]
Explanation An error occurred during an PSM PSS operation. [chars] indicates the PSS operation that caused the error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message PORT-SECURITY-3-SDB_ERR: [chars]
Explanation An error occurred during an FC Management sdb operation. [chars] indicates the operation that caused the error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message PORT-SECURITY-3-SDB_UPDATE_ERR: : [chars]
Explanation FC Management update has failed due to [chars].
Recommended Action No action is required.
Error Message PORT-SECURITY-4-ACTIVATION_FAIL: [chars]
Explanation Activation of bindings failed due to [chars]
Recommended Action Correct the error and reactivate it again
Error Message PORT-SECURITY-4-MAX_LIMIT_REACHED: [chars]
Explanation MGMT_SEC: Max Limit for the config has reached.[chars]
Recommended Action No action is required.
Error Message PORT-SECURITY-4-PSS_WARN: [chars]
Explanation A failure occurred during a PSM PSS operation. [chars] indicates the PSS operation that caused the error
Recommended Action No action is required.
Error Message PORT-SECURITY-6-INFO: [chars]
Explanation An event happend that affects PSM. [chars] indicates the event
Recommended Action No action is required.
Error Message PORT-SECURITY-6-MGMT_SEC_INFO: [chars]
Explanation An event happend that affects FC Management. [chars] indicates the event
Recommended Action No action is required.
This section contains the PORT messages.
Error Message PORT-3-IF_SFP_ALARM: Interface [chars], [chars] [chars] [chars]
Explanation There was an alarm on the transceiver module. [optionally if the port belongs to port-channel, the port-channel number to which the port belongs will be displayed and if interface description is configured, the interface description is displayed]
Recommended Action Please do show interface transceiver details to obtain more information
Error Message PORT-4-IF_SFP_WARNING: Interface [chars], [chars] [chars] [chars]
Explanation There was an warning on the transceiver module. [optionally if the port belongs to port-channel, the port-channel number to which the port belongs will be displayed and if interface description is configured, the interface description is displayed]
Recommended Action Please do show interface transceiver details to obtain more information
This section contains the PRIVATE_VLAN messages.
Error Message PRIVATE_VLAN-2-PVLAN_ASSOC_DOWN_FAILED: Failed to bring down the association between [dec] & [dec]
Explanation Association bringdown failed
Recommended Action No action is required.
Error Message PRIVATE_VLAN-2-PVLAN_ASSOC_UP_FAILED: Failed to bring up the association between [dec] & [dec]
Explanation Association bringup failed
Recommended Action No action is required.
Error Message PRIVATE_VLAN-2-PVLAN_ELTM_MTS_SEND_FAILED: MTS send failed while communicating with ELTM.
Explanation ELTM MTS send failed
Recommended Action No action is required.
Error Message PRIVATE_VLAN-2-PVLAN_ELTM_TIMED_OUT: ELTM timed out while configuring hardware.
Explanation ELTM timed out
Recommended Action No action is required.
Error Message PRIVATE_VLAN-2-PVLAN_ETHPM_TIMED_OUT: ETHPM timed out while configuring/unconfiguring hardware
Explanation ETHPM timed out
Recommended Action No action is required.
Error Message PRIVATE_VLAN-2-PVLAN_FAIL_TO_ASSOCIATE_PRIMARY_WITH_SECONDARY_VLAN: Failed to bring up the association between [dec] & [dec]
Explanation Association between primary and secondary vlan failed due to an error returned by vlan manager
Recommended Action No action is required.
Error Message PRIVATE_VLAN-2-PVLAN_FAIL_TO_COMMUNICATE_REMOVE_VLAN_ASSOCIATION_TO_ELTM: Failed to bring down the association between [dec] & [dec]
Explanation Fail to remove association between primary and secondary vlan due to an error returned by eltm manager
Recommended Action No action is required.
Error Message PRIVATE_VLAN-2-PVLAN_FAIL_TO_COMMUNICATE_VLAN_ASSOCIATION_TO_ELTM: Failed to bring up the association between [dec] & [dec]
Explanation Failed to associate primary and secondary vlan due to an error returned by eltm manager
Recommended Action No action is required.
Error Message PRIVATE_VLAN-2-PVLAN_FAIL_TO_REMOVE_ASSOCIATION_BETWEEN_PRIMARY_AND_SECONDARY_VLAN: Failed to bring down the association between [dec] & [dec]
Explanation Removing association between primary and secondary vlan failed due to an error returned by vlan manager
Recommended Action No action is required.
Error Message PRIVATE_VLAN-2-PVLAN_HW_ERROR: Error [hex] occurred for ifindex [hex] while programming hardware: [chars]
Explanation Hardware Configuration Error
Recommended Action No action is required.
Error Message PRIVATE_VLAN-2-PVLAN_PIXM_MTS_SEND_FAILED: MTS send failed while communicating with PIXM
Explanation PIXM MTS send failed
Recommended Action No action is required.
Error Message PRIVATE_VLAN-2-PVLAN_PIXM_TIMED_OUT: PIXM timed out while configuring hardware.
Explanation PIXM timed out
Recommended Action No action is required.
Error Message PRIVATE_VLAN-3-PVLAN_ASSOC_SDB_UPDATE_FAILED: Failed to update SDB while [chars] association for vlan [dec]
Explanation SDB Update failed
Recommended Action No action is required.
Error Message PRIVATE_VLAN-3-PVLAN_IN_USE: PVLAN [dec] in use by interface [chars], please do "no switchport access vlan" or "no switchport private-vlan host-association"
Explanation PVLAN in use
Recommended Action No action is required.
Error Message PRIVATE_VLAN-3-PVLAN_VLANMGR_FAILURE: Cannot restore association operational state. Failed to communicate with VLAN manager
Explanation Restoring association operational status failed
Recommended Action No action is required.
Error Message PRIVATE_VLAN-5-PVLAN_DISABLED: PVLAN Disabled
Explanation PVLAN Service Disabled
Recommended Action No action is required.
Error Message PRIVATE_VLAN-5-PVLAN_DISABLE_FAILED: Disabling of private-vlan failed. Either shutdown these ports or remove the ports that are in switchport mode private-vlan: [chars]
Explanation Disabling of private-vlan failed
Recommended Action No action is required.
Error Message PRIVATE_VLAN-5-PVLAN_ENABLED: PVLAN Enabled
Explanation PVLAN Service Enabled
Recommended Action No action is required.
Error Message PRIVATE_VLAN-5-PVLAN_VTP_DISABLE_FAILED: Either remove all private-vlans from VTP domain or change VTP to transparent mode
Explanation Disabling of private-vlan failed
Recommended Action No action is required.
This section contains the PROFILER messages.
Error Message PROFILER-0-EMERGENCY_MSG: [chars]
Explanation Profiler Emergency Message
Recommended Action Please file the bug for Profiler Library Component thro' CDETS
Error Message PROFILER-1-ALERT_MSG: [chars]
Explanation Profiler Alert Message
Recommended Action Profiler Internal Operation Alert
Error Message PROFILER-2-CRITICAL_MSG: [chars]
Explanation Profiler Critical Message
Recommended Action No action is required.
Error Message PROFILER-3-ERROR_MSG: [chars]
Explanation Profiler Error Message
Recommended Action No action is required.
Error Message PROFILER-4-WARN_MSG: [chars]
Explanation Profiler Warning Message
Recommended Action No action is required.
Error Message PROFILER-5-NOTIF_MSG: [chars]
Explanation Profiler Notification Message
Recommended Action No action is required.
Error Message PROFILER-6-INFO_MSG: [chars]
Explanation Profiler Informational Message
Recommended Action No action is required.
Error Message PROFILER-7-DEBUG_MSG: [chars]
Explanation Profiler Debug Message
Recommended Action No action is required.
This section contains the PSS messages.
Error Message PSS-2-PSS_ERROR: [chars]
Explanation PSS error log
Recommended Action No action is required.
Error Message PSS-2-PSS_INFRACONVERT: [chars]
Explanation Error in libinfraconvert during pss conversion
Recommended Action No action is required.
Error Message PSS-4-PSS_CLEANUP: [chars]: cleaning up [chars]
Explanation PSS removed a leftover or corrupted file
Recommended Action No action is required.
Error Message PSS-5-PSS_CONVERT_FORMAT: [chars]: converting pss format: [chars]
Explanation PSS format is being converted
Recommended Action No action is required.
Error Message PSS-5-PSS_CONVERT_LAYOUT: [chars]: converting pss layout: [chars] (params [dec]/[dec]/[dec] -> [dec]/[dec]/[dec])
Explanation PSS layout is being converted
Recommended Action No action is required.
Error Message PSS-5-PSS_SHRINK: [chars]: shrinking pss: [chars]
Explanation PSS is being shrunk to remove free space
Recommended Action No action is required.
Error Message PSS-5-SDB_CLOSED_AT_COMMIT: [chars]: sdb [chars] is closed: token [dec] is not committed
Explanation Publisher received SDB commit but sdb was already closed
Recommended Action No action is required.
This section contains the PTPLC messages.
Error Message PTPLC-3-PTPLC_PORT_CFG_FAILED: Configuration failed on port [hex], [chars]: [hex], [chars]
Explanation PTP interface configuration error
Recommended Action No action is required.
Error Message PTPLC-3-PTPLC_PTP_INTF_CONFIG_ERROR: Failed to configure PTP/PONG on port [dec]: [hex], [chars]
Explanation PTP interface configuration error
Recommended Action No action is required.
This section contains the PTP messages.
Error Message PTP-2-PTP_GM_CHANGE_TOLOCAL: Grandmaster clock has changed to local clock [hex]:[hex]:[hex]:[hex]:[hex]:[hex]:[hex]:[hex] for the PTP protocol
Explanation PTP GM changed to local Clock ID
Recommended Action No action is required.
Error Message PTP-2-PTP_GM_CHANGE: Grandmaster clock has changed from [hex]:[hex]:[hex]:[hex]:[hex]:[hex]:[hex]:[hex] to [hex]:[hex]:[hex]:[hex]:[hex]:[hex]:[hex]:[hex] for the PTP protocol
Explanation PTP GM changed
Recommended Action No action is required.
Error Message PTP-2-PTP_STATE_CHANGE: PTP state of interface [chars] is changing from '[chars]' to '[chars]'
Explanation PTP Port state change
Recommended Action No action is required.
Error Message PTP-2-PTP_TIMESYNC_LOST: Loss of synchronization with master clock
Explanation PTP loses synchronization with master clock
Recommended Action No action is required.
Error Message PTP-5-PTP_DISABLED: PTP disabled
Explanation PTP Service Enabled
Recommended Action No action is required.
Error Message PTP-5-PTP_DOMAIN_CHANGE: PTP domain changed to [dec]
Explanation PTP domain changed
Recommended Action No action is required.
Error Message PTP-5-PTP_ENABLED: PTP enabled
Explanation PTP Service Enabled
Recommended Action No action is required.
Error Message PTP-6-PTP_ANNOUNCE_INTERVAL_CHANGE: PTP announce interval for [hex] changed to [dec]
Explanation PTP announce interval for [chars] changed
Recommended Action No action is required.
Error Message PTP-6-PTP_ANNOUNCE_TIMEOUT_CHANGE: PTP announce timeout interval for [hex] changed to [dec]
Explanation PTP announce timeout interval for [chars] changed
Recommended Action No action is required.
Error Message PTP-6-PTP_DELAY_REQ_INTERVAL_CHANGE: PTP delay-req interval for [hex] changed to [dec]
Explanation PTP delay-req interval for [chars] changed
Recommended Action No action is required.
Error Message PTP-6-PTP_PRIORITY1_CHANGE: PTP priority1 changed to [dec]
Explanation PTP priority1 changed
Recommended Action No action is required.
Error Message PTP-6-PTP_PRIORITY2_CHANGE: PTP priority2 changed to [dec]
Explanation PTP priority2 changed
Recommended Action No action is required.
Error Message PTP-6-PTP_SYNC_INTERVAL_CHANGE: PTP sync interval for [hex] changed to [dec]
Explanation PTP sync interval for [chars] changed
Recommended Action No action is required.
Error Message PTP-6-PTP_TIMESYNC_REG_CHANGE: PTP time-sync register changed
Explanation PTP time-sync reg change
Recommended Action No action is required.
Error Message PTP-6-PTP_VLAN_CHANGE: PTP vlan for [hex] changed to [dec]
Explanation PTP vlan for [chars] changed
Recommended Action No action is required.
This section contains the PULSE messages.
Error Message PULSE-0-EMERGENCY_MSG: [chars]
Explanation Pulse Emergency Message
Recommended Action Please file the bug for Pulse Library Component thro' CDETS
Error Message PULSE-1-ALERT_MSG: [chars]
Explanation Pulse Alert Message
Recommended Action Pulse Internal Operation Alert
Error Message PULSE-2-CRITICAL_MSG: [chars]
Explanation Pulse Critical Message
Recommended Action No action is required.
Error Message PULSE-3-ERROR_MSG: [chars]
Explanation Pulse Error Message
Recommended Action No action is required.
Error Message PULSE-4-WARN_MSG: [chars]
Explanation Pulse Warning Message
Recommended Action No action is required.
Error Message PULSE-5-NOTIF_MSG: [chars]
Explanation Pulse Notification Message
Recommended Action No action is required.
Error Message PULSE-6-INFO_MSG: [chars]
Explanation Pulse Informational Message
Recommended Action No action is required.
Error Message PULSE-7-DEBUG_MSG: [chars]
Explanation Pulse Debug Message
Recommended Action No action is required.
This section contains the QOS messages.
Error Message QOS-2-GENERAL_ERROR: [chars]
Explanation The QOS Manager has encountered an critical error. The description of error is [str.].
Recommended Action No action is required.
Error Message QOS-2-PSS_ERROR: [chars]: PSS returned value=[dec]
Explanation The QOS Manager encountered error while operating on a persistent storage database.
Recommended Action No action is required.
Error Message QOS-3-DBERROR: [chars]
Explanation QoS Manager encountered a database error. [chars] specifies the context where the failure occurred.
Recommended Action No action is required.
Error Message QOS-3-FAILURE_RESPONSE: [chars] [hex]
Explanation QoS Manager failed to get response [chars][hex] specify the context where the failure occurred.
Recommended Action No action is required.
Error Message QOS-3-GENERROR: [chars]
Explanation QoS Manager encountered a general error, one that does not fall in any of the above categories. [chars] describes the error and its context.
Recommended Action No action is required.
Error Message QOS-3-LICERR: [chars]
Explanation QoS Manager failed to get license.
Recommended Action No action is required.
Error Message QOS-3-MTSERROR: [chars]
Explanation QoS Manager encountered an MTS error. [chars] specifies the context where the error occurred.
Recommended Action No action is required.
Error Message QOS-3-PSSERROR: [chars]
Explanation QoS Manager encountered a PSS error. [chars] specifies the context where the failure occurred.
Recommended Action No action is required.
Error Message QOS-3-TIMEOUT_ERROR: [chars] [hex]
Explanation QoS Manager encountered a timeout [chars][hex] specify the context where the failure occurred.
Recommended Action No action is required.
Error Message QOS-4-LICEXP: [chars]
Explanation QoS Manager license is going to expire. [chars] gives the expected time of expiry.
Recommended Action No action is required.
Error Message QOS-6-DISABLED_UP_MARKING: [chars]
Explanation The QoS Manager has disabled marking of time-critical control traffic as high-priority traffic. Priority of such traffic is now not altered by QoS Manager.
Recommended Action No action is required.
Error Message QOS-6-ENABLED_UP_MARKING: [chars]
Explanation The QoS Manager has enabled marking of time-critical control traffic as high-priority traffic.
Recommended Action No action is required.
Error Message QOS-6-MGRCREATED: QoS Manager created
Explanation QoS Manager was created successfully and is up and running. This is an informational message.
Recommended Action No action is required.
This section contains the QUACK_SMC messages.
Error Message QUACK_SMC-6-QUACK_LIB_DEBUG_MSG: [chars]
Explanation Debug log message
Recommended Action No action is required.
This section contains the RADIUS messages.
Error Message RADIUS-3-RADIUS_ERROR_MESSAGE: [chars]
Explanation RADIUS Error Message
Recommended Action No action is required.
Error Message RADIUS-4-RADIUS_WARNING: [chars]
Explanation RADIUS Warning
Recommended Action No action is required.
Error Message RADIUS-5-RADIUS_MONITOR_STATUS: [chars] [chars]
Explanation Notifying Radius server monitor status change
Recommended Action No action is required.
Error Message RADIUS-5-RADIUS_NOTIFICATION: [chars]
Explanation RADIUS Notification
Recommended Action No action is required.
Error Message RADIUS-5-RADIUS_SERVER_STATUS: [chars] server [chars] with auth-port [dec] and acct-port [dec] status has changed from [chars] to [chars]. Server was in previous-state for [chars], and total dead time of the server is [chars]
Explanation Notifying Radius server status change
Recommended Action No action is required.
Error Message RADIUS-6-RADIUS_ACCOUNTING_MESSAGE: [chars]
Explanation Accounting Message
Recommended Action No action is required.
Error Message RADIUS-6-RADIUS_MESSAGE: [chars]
Explanation RADIUS Message
Recommended Action No action is required.
This section contains the RES_MGR messages.
Error Message RES_MGR-2-RES_MGR_CRIT: RES_MGR Critical: [chars]
Explanation RES_MGR generic critical condition
Recommended Action No action is required.
Error Message RES_MGR-5-RES_MGR_DISABLED: RES_MGR Disabled
Explanation RES_MGR Service Disabled
Recommended Action No action is required.
Error Message RES_MGR-5-RES_MGR_ENABLED: RES_MGR Enabled
Explanation RES_MGR Service Enabled
Recommended Action No action is required.
This section contains the RIB messages.
Error Message RIB-0-EMERG: [chars]
Explanation Rib caused a system failure
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message RIB-1-ALERT: [chars]
Explanation Rib caused failures in other services
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message RIB-1-LCM_FIB_ERR: RIB failed LC insertion
Explanation RIB stopped linecard from coming online due to error received from FIB during merge operation
Recommended Action Check RIB error logs to see error received from FIB
Error Message RIB-2-CRIT: [chars]
Explanation Rib encountered a catastrophic error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message RIB-3-ERR: [chars]
Explanation Rib encountered an error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message RIB-3-FIB_EXIT: fib exited
Explanation Fib had exited and may not continue operation
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message RIB-3-MISS_APPS: Missing response from service
Explanation Service not responding to rib
Recommended Action Please perform 'debug rib error', then recreate the operation scenario, to find out more details.
Error Message RIB-3-NO_MEM: Out of memory
Explanation Rib does not have enough memory to continue proper operation.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message RIB-3-SEND_FIB: Cannot talk to fib
Explanation Rib to fib IPC failure
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message RIB-3-SEND_SNMP: Cannot respond to snmp
Explanation Rib to snmp IPC failure
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message RIB-3-SEND_STANDBY: Cannot talk to standby rib
Explanation Lost a rib-fib transaction log due to IPC failure
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message RIB-4-CPU_HOG: Inactive or busy
Explanation Either rib was not scheduled to run, or rib was busy, and rib did not service the message or timer queue for an extended period.
Recommended Action Please perform 'debug rib error', then recreate the operation scenario, to find out more details.
Error Message RIB-4-DUP_FIB: Duplicate response from fib
Explanation Rib ignored duplicate response from fib
Recommended Action Please perform 'debug rib error', then recreate the operation scenario, to find out more details.
Error Message RIB-4-LATE_FIB: Late response from fib
Explanation Rib ignored late response from fib
Recommended Action Please perform 'debug rib error', then recreate the operation scenario, to find out more details.
Error Message RIB-4-PC_LIMIT: PC number greater than 128 (ignored by RIB)
Explanation Rib ignored pc > 128 for multicast
Recommended Action Please use PC number < 128
Error Message RIB-4-WARN: [chars]
Explanation Rib ignored the unexpected condition
Recommended Action Please perform 'debug rib all', then recreate the operation scenario, to find out more details.
Error Message RIB-5-NOTE: [chars]
Explanation Rib does not support this operation
Recommended Action Please perform 'debug rib all', then recreate the operation scenario, to find out more details.
Error Message RIB-6-INFO: [chars]
Explanation Rib event occurred
Recommended Action No action is required.
This section contains the SAL messages.
Error Message SAL-5-SAL_DISABLED: SAL Disabled
Explanation SAL Service Disabled
Recommended Action No action is required.
Error Message SAL-5-SAL_ENABLED: SAL Enabled
Explanation SAL Service nabled
Recommended Action No action is required.
This section contains the SCHEDULER messages.
Error Message SCHEDULER-3-SCH_ERR: [chars]
Explanation Scheduler error
Recommended Action No action is required.
Error Message SCHEDULER-4-SCH_WARN: [chars]
Explanation Scheduler warning
Recommended Action No action is required.
Error Message SCHEDULER-6-SCH_MSG: [chars]
Explanation Scheduler Message
Recommended Action No action is required.
This section contains the SECURITYD messages.
Error Message SECURITYD-2-FIPS_BYPASS_SELF_TEST_STATUS: FIPS Bypass self-test status : [chars]
Explanation Status of FIPS self-test [chars]
Recommended Action No action is required.
Error Message SECURITYD-2-FIPS_CRNG_SELF_TEST_STATUS: FIPS CRNG self-test status : [chars]
Explanation Status of FIPS self-test [chars]
Recommended Action No action is required.
Error Message SECURITYD-2-FIPS_CRYPTO_SELF_TEST_STATUS: FIPS [chars] Crypto self-test status : [chars]
Explanation Status of FIPS [chars] self-test [chars]
Recommended Action No action is required.
Error Message SECURITYD-2-FIPS_POST_ERROR_MSG: [chars]
Explanation Fips post Error Message
Recommended Action No action is required.
Error Message SECURITYD-2-FIPS_POST_MAINTENANCE: FIPS Test failed. Moving to maintenance mode
Explanation FIPS Test failed. Moving to maintenance mode
Recommended Action No action is required.
Error Message SECURITYD-2-FIPS_POST_TEST_FAILED: FIPS crypto-test failure : [dec]
Explanation FIPS crytpo-test failed [chars]
Recommended Action No action is required.
Error Message SECURITYD-2-FIPS_POWERUP_SELF_TESTS_STATUS: FIPS power-up self-test status: [chars]
Explanation Status FIPS self-test [chars]
Recommended Action No action is required.
Error Message SECURITYD-2-FIPS_POWERUP_SELF_TEST_STATUS: FIPS [chars] power-up self-test status : [chars]
Explanation Status of FIPS [chars] power-up self-test [chars]
Recommended Action No action is required.
Error Message SECURITYD-2-FIPS_SELF_TEST_FAILED: FIPS self-test failure : [chars] : [chars]
Explanation FIPS self-test failed [chars] for service [chars]
Recommended Action No action is required.
Error Message SECURITYD-2-INVALID_ADMIN_PASSWD: User admin has NULL password. Copy r s aborted
Explanation User admin has NULL password. Copy r s aborted
Recommended Action No action is required.
Error Message SECURITYD-3-NVRAMFAILURE: nvram failure
Explanation Nvram can not be read/written to. Hence accounting log can not be stored there
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message SECURITYD-6-ACCOUNTING_MESSAGE: [chars]
Explanation Accounting Message
Recommended Action No action is required.
Error Message SECURITYD-6-CHANGE_PASSWD: changing passwd for [chars]
Explanation Changing passwd for [chars]
Recommended Action No action is required.
Error Message SECURITYD-6-DELETE_STALE_USER_ACCOUNT: deleting expired user account:[chars]
Explanation Deleting expired user account of [chars]
Recommended Action No action is required.
Error Message SECURITYD-6-FIPS_MODE_SET_FAILED: Error when setting FIPS mode : [chars]
Explanation FIPS mode failed [chars]
Recommended Action No action is required.
Error Message SECURITYD-6-FIPS_MODE_SET: FIPS mode is [chars] for service [chars]
Explanation FIPS mode is changed [chars] [chars]
Recommended Action No action is required.
Error Message SECURITYD-6-FIPS_POST_INFO_MSG: [chars]
Explanation Fips post Information Message
Recommended Action No action is required.
This section contains the SENSOR messages.
Error Message SENSOR-0-DC3_SENSOR_MSG: [chars]
Explanation SENSOR log emergency message
Recommended Action No action is required.
Error Message SENSOR-3-DC3_SENSOR_MSG1: [chars]
Explanation SENSOR log message
Recommended Action No action is required.
This section contains the SFLOW messages.
Error Message SFLOW-5-SFLOW_DISABLED: SFLOW Disabled
Explanation SFLOW Service Disabled
Recommended Action No action is required.
Error Message SFLOW-5-SFLOW_ENABLED: SFLOW Enabled
Explanation SFLOW Service nabled
Recommended Action No action is required.
This section contains the SKSD messages.
Error Message SKSD-2-SKSD_CRYPT_SERVICE_CRIT: Encryption-Service: [chars]
Explanation Encryption Service critical errors.
Recommended Action No action is required.
Error Message SKSD-3-SKSD_CRYPT_SERVICE_ERR: Encryption-Service: [chars]
Explanation Encryption Service errors.
Recommended Action No action is required.
Error Message SKSD-3-SKSD_FIPS_MODE_INIT_ERROR: Could not initialize FIPS mode : [chars]
Explanation FIPS mode initialization error
Recommended Action No action is required.
Error Message SKSD-3-SKSD_FIPS_MODE_SELFTEST: FIPS POST for [chars] [chars]
Explanation FIPS Selftest Result
Recommended Action No action is required.
Error Message SKSD-4-SKSD_CRYPT_SERVICE_WARN: Encryption-Service: [chars]
Explanation Encryption Service warnings.
Recommended Action No action is required.
Error Message SKSD-5-SKSD_CRYPT_SERVICE_NOTICE: Encryption Service: [chars]
Explanation Encryption Service updates.
Recommended Action No action is required.
Error Message SKSD-5-SKSD_EXIT: Keystore Application Exiting: [chars]
Explanation Keystore Program exiting
Recommended Action No action is required.
Error Message SKSD-5-SKSD_FUNC: Keystore Operation: [chars]
Explanation Keystore Event upon a receiving a request
Recommended Action No action is required.
Error Message SKSD-5-SKSD_HW_INIT: Hardware Keystore Init done
Explanation Hardware Keystore Init completed
Recommended Action No action is required.
Error Message SKSD-5-SKSD_HW_RESET: Hardware Reset :[chars]
Explanation Hardware Reset
Recommended Action No action is required.
Error Message SKSD-5-SKSD_HW: Smartcard :[chars]
Explanation Smartcard Presence
Recommended Action No action is required.
Error Message SKSD-5-SKSD_INIT: Keystore Application Init: [chars]
Explanation Keystore Program Init
Recommended Action No action is required.
Error Message SKSD-5-SKSD_KEY_ADD: Key added
Explanation Key added to keystore
Recommended Action No action is required.
Error Message SKSD-5-SKSD_KEY_DELETE: Key deleted
Explanation Key deleted from keystore
Recommended Action No action is required.
Error Message SKSD-5-SKSD_SUP_STATE: Supervisor card new state: [dec]
Explanation Supervisor state change
Recommended Action No action is required.
Error Message SKSD-5-SKSD_SW_INIT: Software Keystore Init done
Explanation Software Keystore Init completed
Recommended Action No action is required.
Error Message SKSD-6-SKSD_CRYPT_SERVICE_INFO: Encryption Service: [chars]
Explanation Encryption Service informational updates.
Recommended Action No action is required.
This section contains the SME_CPP messages.
Error Message SME_CPP-3-LOG_SME_DISK_ASL_FAILED: [chars]
Explanation SME KMC disk asl token generation failed for the given device discovery info
Recommended Action No action is required.
Error Message SME_CPP-5-SME_DISABLED: SME Disabled
Explanation SME Service Disabled
Recommended Action No action is required.
Error Message SME_CPP-5-SME_ENABLED: SME Enabled
Explanation SME Service nabled
Recommended Action No action is required.
This section contains the SNMPD messages.
Error Message SNMPD-1-ALERT: SNMP log alert : [chars]
Explanation SNMP log alert message.
Recommended Action No action is required.
Error Message SNMPD-2-CRITICAL: SNMP log critical : [chars]
Explanation SNMP log critical message.
Recommended Action No action is required.
Error Message SNMPD-3-ERROR: SNMP log error : [chars]
Explanation SNMP log error message.
Recommended Action No action is required.
Error Message SNMPD-4-WARNING: SNMP log warning : [chars]
Explanation SNMP log warning message.
Recommended Action No action is required.
Error Message SNMPD-5-NOTIFICATION: SNMP log notification : [chars]
Explanation SNMP log notification message.
Recommended Action No action is required.
Error Message SNMPD-6-INFO: SNMP log informational : [chars]
Explanation SNMP log info message.
Recommended Action No action is required.
Error Message SNMPD-7-DEBUG: SNMP log debugging : [chars]
Explanation SNMP log debug message.
Recommended Action No action is required.
This section contains the STATSCLIENT messages.
Error Message STATSCLIENT-2-STATSCL_CRIT: [chars]
Explanation StatsClient Critical Message
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message STATSCLIENT-3-STATSCL_ERR2: [chars] [dec] [dec]
Explanation StatsClient Error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message STATSCLIENT-3-STATSCL_ERR: [chars] [dec]
Explanation StatsClient Error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message STATSCLIENT-6-STATSCL_INFO: [chars]
Explanation StatsClient Flow Message
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
This section contains the STATSINFRA messages.
Error Message STATSINFRA-3-STATS_INFRA_CRIT: [chars]
Explanation StatsInfra Critical Message
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message STATSINFRA-3-STATS_INFRA_ERR: [chars]
Explanation StatsInfra Error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message STATSINFRA-3-STATS_INFRA_INFO: [chars]
Explanation StatsInfra Flow Message
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
This section contains the STP messages.
Error Message STP-2-RANDNUM_FAIL: [chars]
Explanation There was a critical error during random number generation. [chars] indicates details of the error
Recommended Action No action is required.
This section contains the TACACS messages.
Error Message TACACS-3-TACACS_ERROR_MESSAGE: [chars]
Explanation TACACS+ Error Message
Recommended Action No action is required.
Error Message TACACS-4-TACACS_WARNING: [chars]
Explanation TACACS+ warning
Recommended Action No action is required.
Error Message TACACS-5-TACACS_MONITOR_STATUS: [chars] [chars]
Explanation Notifying Tacacs+ server monitor status change
Recommended Action No action is required.
Error Message TACACS-5-TACACS_NOTIFICATION: [chars]
Explanation TACACS+ notification
Recommended Action No action is required.
Error Message TACACS-5-TACACS_SERVER_STATUS: [chars] server [chars] with auth-port [dec] and acct-port [dec] status has changed from [chars] to [chars]. Server was in previous-state for [chars], and total dead time of the server is [chars]
Explanation Notifying Tacacs+ server status change
Recommended Action No action is required.
Error Message TACACS-6-TACACS_ACCOUNTING_MESSAGE: [chars]
Explanation Accounting Message
Recommended Action No action is required.
Error Message TACACS-6-TACACS_MESSAGE: [chars]
Explanation TACACS+ Message
Recommended Action No action is required.
This section contains the TAHUSD messages.
Error Message TAHUSD-2-TAHUSD_SYSLOG_PFCWD_QUEUE_RESTORED: [chars]
Explanation NO DROP Queue Restored due to PFC WatchDog timer expiring message
Recommended Action No action is required.
Error Message TAHUSD-2-TAHUSD_SYSLOG_PFCWD_QUEUE_SHUTDOWN: [chars]
Explanation Queue Shutdown due to PFC WatchDog timer expiring as a result of NO DROP Queue stuck message
Recommended Action No action is required.
Error Message TAHUSD-3-TAHUSD_SPEED_MSG: [chars]
Explanation TAHUSD Error: same port speed must be set within a 4-port group
Recommended Action No action is required.
Error Message TAHUSD-6-TAHUSD_SYSLOG_INFO: [chars]
Explanation Tahoe log message
Recommended Action No action is required.
This section contains the TBIRD_CMN_USD messages.
Error Message TBIRD_CMN_USD-6-TBIRD_CMN_DEBUG_MSG: [chars]
Explanation Debug log message
Recommended Action No action is required.
This section contains the TELEMETRY messages.
Error Message TELEMETRY-1-ALERT: [chars]
Explanation Alert message
Recommended Action ACTION_NONE
Error Message TELEMETRY-2-CRITICAL: [chars]
Explanation Critical message
Recommended Action ACTION_NONE
Error Message TELEMETRY-3-ERROR: [chars]
Explanation Error message
Recommended Action ACTION_NONE
Error Message TELEMETRY-3-INITERR: TM initialized [chars] failed
Explanation Initialization failures condition
Recommended Action ACTION_NONE
Error Message TELEMETRY-3-TRANSPORT_SEND_ERROR: [chars] send to [chars] failed. ([chars])
Explanation Telemetry transport send failure.
Recommended Action Make sure receiver is up and running.
Error Message TELEMETRY-4-DISABLE_DONE: [chars]
Explanation Telemetry is now disabled. You can re-enable the feature if needed.
Recommended Action ACTION_NONE
Error Message TELEMETRY-4-DISABLING_FEATURE: [chars]
Explanation Telemetry is being disabled. Please wait until process terminates.
Recommended Action Don't re-enable telemetry until the process exits.
Error Message TELEMETRY-4-TRANSPORT_RECONFIGURE: [chars]
Explanation A configuration change requires reconfiguring destination groups to take effect.
Recommended Action Reconfigure telemetry destination groups.
Error Message TELEMETRY-4-WARNING: [chars]
Explanation Warning message
Recommended Action ACTION_NONE
Error Message TELEMETRY-5-NOTICE: [chars]
Explanation Normal bug significant condition
Recommended Action ACTION_NONE
Error Message TELEMETRY-6-INFO: [chars]
Explanation Informational message
Recommended Action ACTION_NONE
Error Message TELEMETRY-7-DEBUG: [chars]
Explanation Debug message
Recommended Action ACTION_NONE
This section contains the TUNNEL messages.
Error Message TUNNEL-2-FEATURE_ENABLE_FAILED: failed to enable feature tunnel, reason [chars] ([hex])
Explanation Failed to enable feature tunnel, reason [char] ([int])
Recommended Action Check the failure reason and take appropriate action to fix the failure. if unable to fix, please capture "show tech-support tunnel"
Error Message TUNNEL-2-TUNNEL_INTF_STATE_UPDATE: Interface [chars] is down reason ([chars])
Explanation Interface [char] is down reason [char]
Recommended Action No action is required.
Error Message TUNNEL-2-UNSUPPORTED_TUNNEL_TYPE: Failed to create interface [chars] due to unsupported-tunnel type
Explanation Current tunnel type is not supported in this release
Recommended Action No action is required.
Error Message TUNNEL-3-HW_PROGRAMMING_FAILED: for [chars], reason [chars]
Explanation Hardware programming failed for tunnel [num] interface
Recommended Action Try 'shutdown' and 'no shutdown' under tunnel interface submode after sometime. if still tunnel interface doesn't come up capture show tech-support tunnel to identify the issue
Error Message TUNNEL-5-IF_CLEAR_COUNTER: Interface [chars] counters is cleared
Explanation Interface [char] counters is cleared
Recommended Action No action is required.
Error Message TUNNEL-5-IF_CREATED: Interface [chars] is created
Explanation Interface [char] is created
Recommended Action No action is required.
Error Message TUNNEL-5-IF_CREATE_FAILED: Interface [chars] creation failed due to [[hex]] [chars]
Explanation Interface [char] is creation failed due to [int] [char]
Recommended Action No action is required.
Error Message TUNNEL-5-IF_DELETED: Interface [chars] is deleted
Explanation Interface [char] is deleted
Recommended Action No action is required.
Error Message TUNNEL-5-IF_STATE_UPDATE: Interface [chars] is [chars] reason [chars]
Explanation Interface [char] is [char] reason [char]
Recommended Action No action is required.
Error Message TUNNEL-5-PPF_SESSION_FAILED: session id %llx type [chars] for [chars] failed error [hex] [chars]
Explanation Session id [int] type [char] for [char] failed error [int] [char]
Recommended Action No action is required.
Error Message TUNNEL-5-TM_DISABLED: Tunnel Disabled
Explanation Tunnel Service Disabled
Recommended Action No action is required.
Error Message TUNNEL-5-TM_ENABLED: Tunnel Enabled
Explanation Tunnel Service Enabled
Recommended Action No action is required.
Error Message TUNNEL-7-TM_INFO: [chars]
Explanation Tunnel Service info
Recommended Action No action is required.
This section contains the U2RIB messages.
Error Message U2RIB-5-U2RIB_DISABLED: U2RIB Disabled
Explanation U2RIB Service Disabled
Recommended Action No action is required.
Error Message U2RIB-5-U2RIB_ENABLED: U2RIB Enabled
Explanation U2RIB Service enabled
Recommended Action No action is required.
This section contains the UDLD messages.
Error Message UDLD-5-UDLD_AGGRESSIVE: UDLD Aggressive
Explanation UDLD Service Aggressive
Recommended Action No action is required.
Error Message UDLD-5-UDLD_DISABLED: UDLD Disabled
Explanation UDLD Service Disabled
Recommended Action No action is required.
Error Message UDLD-5-UDLD_ENABLED: UDLD Enabled
Explanation UDLD Service Enabled
Recommended Action No action is required.
This section contains the UFDM messages.
Error Message UFDM-5-DNLD_TIMEDOUT: Download timer expired: [chars]
Explanation UFDM download timer expired. Collect show tech-support forwarding l3 unicast for futher analysis.
Recommended Action No action is required.
This section contains the USDBA messages.
Error Message USDBA-6-USDBA_DEBUG_MSG: [chars]
Explanation Debug log message
Recommended Action No action is required.
This section contains the VLAN_MGR messages.
Error Message VLAN_MGR-2-CRITICAL_MSG: [chars]
Explanation VLAN Manager Critical Message
Recommended Action No action is required.
Error Message VLAN_MGR-2-FABRIC_DYNAMIC_CORE_VLAN_RANGE_REMOVED: Fabric dynamic and core VLAN ranges removed. Please delete VLANs [chars] in the ranges
Explanation VLAN Manager Core VLAN Range Removal Message
Recommended Action No action is required.
Error Message VLAN_MGR-2-VLAN_DELETE_FAILED_RSN_BD_EXIST: VTP request to delete VLAN(s) [chars] could not be processed. Bridge Domains exist for VLANs [chars]
Explanation VLAN delete failed since Bridge Domains Exist
Recommended Action No action is required.
Error Message VLAN_MGR-3-ERROR_MSG: [chars]
Explanation VLAN manager error
Recommended Action No action is required.
Error Message VLAN_MGR-4-WARN_MSG: [chars]
Explanation VLAN manager warning
Recommended Action No action is required.
Error Message VLAN_MGR-5-NOTIF_MSG: [chars]
Explanation VLAN Manager Notification Message
Recommended Action No action is required.
Error Message VLAN_MGR-5-RESERVED_VLAN_RANGE_CHANGED: New Reserved VLAN Range Configured From VLAN [dec] to VLAN [dec]
Explanation VLAN Manager Reserved VLAN Reconfiguration Message
Recommended Action No action is required.
Error Message VLAN_MGR-6-INFO_MSG: [chars]
Explanation VLAN manager info
Recommended Action No action is required.
Error Message VLAN_MGR-6-VLAN_CREATED: VLAN [dec], created
Explanation VLAN created
Recommended Action No action is required.
Error Message VLAN_MGR-6-VLAN_MGR_STATEFULL_RESTART: VLAN Manager statefull restart
Explanation VLAN Manager statefull restart
Recommended Action No action is required.
Error Message VLAN_MGR-6-VLAN_MGR_STATELESS_RESTART: VLAN Manager stateless restart
Explanation VLAN Manager stateless restart
Recommended Action No action is required.
Error Message VLAN_MGR-6-VLAN_OPER_STATUS_CHG: VLAN [dec], status changed to [chars]
Explanation VLAN operational state change
Recommended Action No action is required.
This section contains the VMTRACKER messages.
Error Message VMTRACKER-2-VMTRACKER_CONNECTION_ISSUE: Problem with connection: [chars]
Explanation Connection problem
Recommended Action Problem with connection. Try "no connect"; "connect"
Error Message VMTRACKER-2-VMTRACKER_HMM_REGISTRATION_FAIL: [chars]
Explanation HMM Registration error
Recommended Action No action is required.
Error Message VMTRACKER-2-VMTRACKER_TRUNK_MODE_WARN: Interface [chars] is used by VMTracker. Changing it back to TRUNK mode.
Explanation Port trunk mode warning message
Recommended Action Do not change port mode when it is used by VMTracker. To change the mode, disable VMTracker on the interface first.
Error Message VMTRACKER-3-VMTRACKER_SOAP_ERR: Soap Err:[chars]
Explanation Soap Call failure message
Recommended Action No action is required.
Error Message VMTRACKER-4-VMTRACKER_HMM_TRIGGER_FAIL: auto-config trigger failure, vlan [dec] [chars]
Explanation HMM Request error
Recommended Action No action is required.
Error Message VMTRACKER-4-VMTRACKER_SOAP_WARN: Soap Warn:[chars]
Explanation Soap Call warning message
Recommended Action No action is required.
Error Message VMTRACKER-5-VMTRACKER_CONFIG_VLAN: [chars]
Explanation Vlan configuration message
Recommended Action No action is required.
Error Message VMTRACKER-5-VMTRACKER_CREATE_VLAN: Vlan Created: [chars]
Explanation Vlan addition message
Recommended Action No action is required.
Error Message VMTRACKER-5-VMTRACKER_DISABLED: Service Disabled
Explanation Service Disabled
Recommended Action No action is required.
Error Message VMTRACKER-5-VMTRACKER_ENABLED: Service Enabled
Explanation Service enabled
Recommended Action No action is required.
Error Message VMTRACKER-5-VMTRACKER_MESSAGE: [chars]
Explanation Generic message
Recommended Action No action is required.
Error Message VMTRACKER-5-VMTRACKER_REMOVE_VLAN: Vlan Removed: [chars]
Explanation Vlan deletion message
Recommended Action No action is required.
This section contains the VNSEGMENT_MGR messages.
Error Message VNSEGMENT_MGR-2-RANDNUM_FAIL: [chars]
Explanation There was a critical error during random number generation. [chars] indicates details of the error
Recommended Action No action is required.
This section contains the VNTAGC messages.
Error Message VNTAGC-5-VNTAGC_GENERIC_SYSLOG: [chars]
Explanation VNTag Manager Client Generic Syslog
Recommended Action No action is required.
This section contains the VNTAG_MGR messages.
Error Message VNTAG_MGR-2-VLAN_DVIF_ALLOC_FAILURE: DVIF allocation failure for VLANs [chars]. Reason: [chars].
Explanation Flood DVIF allocation failure for VLANs.
Recommended Action No action is required.
Error Message VNTAG_MGR-5-VNTAG_MGR_DISABLED: VNTag Manager Disabled
Explanation VNTag Manager Service Disabled
Recommended Action No action is required.
Error Message VNTAG_MGR-5-VNTAG_MGR_ENABLED: VNTag Manager Enabled
Explanation VNTag Manager Service Enabled
Recommended Action No action is required.
Error Message VNTAG_MGR-5-VNTAG_MGR_GENERIC_SYSLOG: [chars]
Explanation VNTag Manager Generic Syslog
Recommended Action No action is required.
This section contains the VPC messages.
Error Message VPC-2-L3_VPC_UNEQUAL_WEIGHT: Layer3 peer-router is enabled. Please make sure both vPC peers have the same L3 routing configuration
Explanation Unequal weight routing is not supported when layer3 peer-router is enabled
Recommended Action No action is required.
Error Message VPC-2-PCINFO_MISMATCH: PCINFO mismatching on if_index [hex]
Explanation PCINFO mismatching
Recommended Action No action is required.
Error Message VPC-2-PEER_KEEP_ALIVE_RECV_FAIL: In domain [dec], VPC peer keep-alive receive has failed
Explanation Peer keep-alive receive failed
Recommended Action No action is required.
Error Message VPC-2-PEER_KEEP_ALIVE_SEND_FAIL: In domain [dec], VPC peer keep-alive send has failed
Explanation Peer keep-alive send failed
Recommended Action No action is required.
Error Message VPC-2-PEER_VPC_RESP_TIMEDOUT: Failed to receive response from peer for vPC: [dec]
Explanation VPC bringup failed
Recommended Action No action is required.
Error Message VPC-2-PHY_PORT_VPC_CFG_WARNING: phy-port vPC: [dec] is not suggested to be configured with M-series peer-link
Explanation Peer-link on M-series LC is not supported for phy-port vPC
Recommended Action No action is required.
Error Message VPC-2-RECV_ES_CONFLICT: Received conflict for ES: [dec] with system-id: [chars]
Explanation Received conflict for ES. Bring down all vpcs.
Recommended Action No action is required.
Error Message VPC-2-TRACK_INTFS_DOWN: In domain [dec], vPC tracked interfaces down, suspending all vPCs and keep-alive
Explanation VPC tracked object down
Recommended Action No action is required.
Error Message VPC-2-VPC_ADD_L3_BKUP_BD_TO_PEER_GW_EXCLUDE_LIST: Exclude L3 backup routing bridge-domain from vpc peer-gateway config.
Explanation Triggered when peer-link is F1 and peer-gateway is configured without exclude-bridge-domain list.
Recommended Action No action is required.
Error Message VPC-2-VPC_ADD_L3_BKUP_VLAN_TO_PEER_GW_EXCLUDE_LIST: Exclude L3 backup routing VLAN from vpc peer-gateway config.
Explanation Triggered when peer-link is F1 and peer-gateway is configured without exclude-vlan / exclude-bridge-domain list.
Recommended Action No action is required.
Error Message VPC-2-VPC_BDI_EXCLUDE: vPC [dec] has up bridge-domain [chars] which are excluded from suspension on dual-active
Explanation VPC track object BDI deconfigured
Recommended Action No action is required.
Error Message VPC-2-VPC_CORE_PORT_FPATH_BUP_FAILED: Failed to bring up vPC+ peer link port [chars] in Fabric Path Port Mode - vPC+ Fabric Path switch ID not configured
Explanation VPC+ Failed to bringup peer-link - switch-ID not configured
Recommended Action No action is required.
Error Message VPC-2-VPC_ES_FAILED_LID_ALLOC: Failed to negotiate common LID between vPC peers.
Explanation Failed to find common lid.
Recommended Action No action is required.
Error Message VPC-2-VPC_ES_FAILED_PEERLINK_DOWN: Peer-link bringup event sequence failed. Bringing down peer-link.
Explanation Triggered in mcecm_em_es_failed. Bring down peer-link.
Recommended Action No action is required.
Error Message VPC-2-VPC_ES_PEER_LINK_OPERATION_FAILED: Peer-link operation failed due to SAP [dec].
Explanation Triggered in mcecm_cfg_es_failed when peer-link bringup fails.
Recommended Action No action is required.
Error Message VPC-2-VPC_GRACEFUL_SUSP_ALL_VPC: Operational graceful type-1 check state changed, reinitiating all vPCs
Explanation Graceful state change,reinit vPCs
Recommended Action No action is required.
Error Message VPC-2-VPC_ISSU_END: Peer vPC switch ISSU end, unlocking configuration
Explanation Peer vPC switch issu end
Recommended Action No action is required.
Error Message VPC-2-VPC_ISSU_INCOMPAT_APP_PARAM: ISSU operation resulted in incompatible parameters
Explanation Incompatible parameters were not handled for some apps across vPC peers
Recommended Action No action is required.
Error Message VPC-2-VPC_ISSU_START: Peer vPC switch ISSU start, locking configuration
Explanation Peer vPC switch issu start
Recommended Action No action is required.
Error Message VPC-2-VPC_LC_FAIL: LC [dec] does not support required hardware for vPC; run 'show vdc membership status' for port status
Explanation Lc insertion failed
Recommended Action No action is required.
Error Message VPC-2-VPC_NON_DEF_LID: vPC+ negotiated non-default local id. Flapping orphan edge ports recommended.
Explanation Triggered in mcecm_em_es_failed. Bring down peer-link.
Recommended Action No action is required.
Error Message VPC-2-VPC_PEER_LINK_FPATH_BUP_FAILED: Failed to bring up vPC+ peer link port [chars] - port [chars] is not configured as a Fabric Path port
Explanation VPC+ Failed to bringup Peer-link - not in Fabric Path mode
Recommended Action No action is required.
Error Message VPC-2-VPC_PSS_ERROR: [chars], 0x([hex]) present in VPC DB but not is IM DB
Explanation Triggered when vpc DB and IM SDB are inconsistent
Recommended Action No action is required.
Error Message VPC-2-VPC_RC_CLEANUP_FAILURE_NEED_REINIT_MCT: vPC role change cleanup has encountered a failure. Please reinit peer-link to recover. Error: [chars]
Explanation VPC RC failure, need to reinit peer-link
Recommended Action No action is required.
Error Message VPC-2-VPC_RC_FAILURE_NEED_REINIT_MCT: vPC role change has encountered a failure, can not clean up. Please reinit peer-link to recover. Error: [chars]
Explanation VPC RC failure, need to reinit peer-link
Recommended Action No action is required.
Error Message VPC-2-VPC_RC_INIT_FAILURE_MCT_CMPT_FAIL: Can't perform role change since there are type-1 check failures on peer-link at peer side.
Explanation VPC RC failure, due to cmpt failed on peer-link at peer side
Recommended Action No action is required.
Error Message VPC-2-VPC_RC_INIT_FAILURE_PEER_CMPT_FAIL: Can't perform role change since there are vpc legs with type-1 check failure at peer side.
Explanation VPC RC failure, due to cmpt failed vpcs at peer side
Recommended Action No action is required.
Error Message VPC-2-VPC_RC_INIT_FAILURE_UNFINISHED_RC: Can't perform role change since there is another unfinished role change request on either local or peer side. Please wait until it is finished.
Explanation VPC RC failure, due to an unfinished RC
Recommended Action No action is required.
Error Message VPC-2-VPC_SDB_UPD_FAIL: Failed to update shared database. De-config and config vPC [dec] to be consistent.
Explanation SDB update failed while updating
Recommended Action No action is required.
Error Message VPC-2-VPC_SHUTDOWN: vPC shutdown status is [chars]
Explanation VPC shutdown status change
Recommended Action No action is required.
Error Message VPC-2-VPC_SUSP_ALL_VPC: Peer-link going down, suspending all vPCs on secondary
Explanation Peer link down suspend vPCs
Recommended Action No action is required.
Error Message VPC-2-VPC_SVI_EXCLUDE: vPC [dec] has up vlans [chars] which are excluded from suspension on dual-active
Explanation VPC track object deconfigured
Recommended Action No action is required.
Error Message VPC-3-FEX_AA_NO_SUPPPORT: FEX AA not supported
Explanation FEX AA not supported
Recommended Action No action is required.
Error Message VPC-3-GLOBAL_CONSISTENCY_FAILED: In domain [dec], global configuration is not consistent ([chars])
Explanation Global compat-check failed
Recommended Action No action is required.
Error Message VPC-3-INTF_CONSISTENCY_FAILED: In domain [dec], VPC [dec] configuration is not TYPE-1 consistent ([chars])
Explanation MCEC compat-check failed
Recommended Action No action is required.
Error Message VPC-3-PEER_UNREACHABLE: Remote Switch Unreachable
Explanation Peer unreachable
Recommended Action No action is required.
Error Message VPC-3-PEER_VPC_BRINGUP_FAILED: Peer vPC [dec] bringup failed ([chars])
Explanation Peer vPC bringup failed
Recommended Action No action is required.
Error Message VPC-3-VDC_MISMATCH: VDC type mismatch on the vpc peer
Explanation VDC type mismatch on the vpc peer
Recommended Action No action is required.
Error Message VPC-3-VPCM_ASSERTION_FAILED: [chars]
Explanation VPCM has hit an assert condition at file [chars]
Recommended Action No action is required.
Error Message VPC-3-VPCM_INIT_FAIL: vPC Manager Initialization Failed ([chars])
Explanation VPCM Initialization failed. due to [chars]
Recommended Action No action is required.
Error Message VPC-3-VPCM_INTERNAL_ERR: [chars]
Explanation VPCM encountered an internal error due to [chars]
Recommended Action No action is required.
Error Message VPC-3-VPCM_MTS_ERR: [chars]
Explanation VPCM encountered an MTS error due to [chars]
Recommended Action No action is required.
Error Message VPC-3-VPC_BRINGUP_FAILED: vPC [dec] bringup failed ([chars])
Explanation VPC bringup failed
Recommended Action No action is required.
Error Message VPC-3-VPC_PEER_LINK_BRINGUP_FAILED: vPC peer-link bringup failed ([chars])
Explanation VPC Peer-link bringup failed
Recommended Action No action is required.
Error Message VPC-3-VPC_PEER_LINK_DOWN: VPC Peer-link is down
Explanation VPC Peer link is down
Recommended Action No action is required.
Error Message VPC-3-VPC_RC_FAILURE_NO_NEED_REINIT_MCT: vPC role change has encountered a failure, will clean up, error: [chars]
Explanation VPC RC failure, no need to reinit peer-link
Recommended Action No action is required.
Error Message VPC-4-FTAG_UPD_PORT_DWN: Warning: receive FTAG update while port is going down
Explanation Receive FTAG update while port is going down
Recommended Action No action is required.
Error Message VPC-4-OOB_DWN_BUT_WAS_ALIVE: Warning: Bring up peer-link when peer keep-alive is down
Explanation Try to bring up MCT when OOB fails.
Recommended Action No action is required.
Error Message VPC-4-PEER_VPC_DELETED: Peer vPC [dec] deleted
Explanation Peer vPC configuration deleted
Recommended Action No action is required.
Error Message VPC-4-VPC_CONSISTENCY_NEW_VLAN_FAIL: Global Consistency check for vPC failed for new vlans
Explanation Global Consistency check for vPC failed for new vlans
Recommended Action No action is required.
Error Message VPC-4-VPC_DELETED: vPC [dec] is deleted
Explanation VPC configuration deleted
Recommended Action No action is required.
Error Message VPC-4-VPC_LC_UPG_OVER_DELIVERY_FAIL: Failed to deliver LC upgrade to vPC peer
Explanation Failed to deliver LC upgrade to peer
Recommended Action No action is required.
Error Message VPC-4-VPC_PEER_LINK_DELETED: vPC Peer-link deleted. This will bringdown all vPC interfaces
Explanation VPC Peer-link configuration removed
Recommended Action No action is required.
Error Message VPC-4-VPC_PEER_ROLE_CHANGE: In domain [dec], VPC peer role status has changed to [chars]
Explanation VPC Peer role status changed to (Primary/Secondary
Recommended Action No action is required.
Error Message VPC-4-VPC_PER_VLAN_CONSISTENCY_FAILED: Global consistency check for vPC failed for few vlans
Explanation Global Consistency check for vPC failed for few vlans
Recommended Action No action is required.
Error Message VPC-4-VPC_REINITIALIZED: Reinitializing vpcs assuming peer dead
Explanation Initializing vpcs assuming peer dead
Recommended Action No action is required.
Error Message VPC-4-VPC_ROLE_CHANGE: In domain [dec], VPC role status has changed to [chars]
Explanation VPC role status changed to (Primary/Secondary
Recommended Action No action is required.
Error Message VPC-5-GLOBAL_CONSISTENCY_SUCCESS: In domain [dec], global configuration is consistent
Explanation Global compat-check passed
Recommended Action No action is required.
Error Message VPC-5-INTF_CONSISTENCY_SUCCESS: In domain [dec], vPC [dec] configuration is TYPE-1 consistent
Explanation VPC configuration is consistent
Recommended Action No action is required.
Error Message VPC-5-ORPHANPORT_RESUME: Orphan-port [chars] is removed from suspended
Explanation Orphan-port is removed from suspended due to peer-link up or VPC role selection
Recommended Action No action is required.
Error Message VPC-5-ORPHANPORT_SUSPEND: Orphan-port [chars] is suspended
Explanation Orphan-port is suspended due to peer-link down or no VPC role selection
Recommended Action No action is required.
Error Message VPC-5-PEER_KEEP_ALIVE_RECV_INT_LATEST: In domain [dec], VPC peer-keepalive received on interface [chars]
Explanation VPC peer-keepalive receive interface changed
Recommended Action No action is required.
Error Message VPC-5-PEER_KEEP_ALIVE_RECV_SUCCESS: In domain [dec], vPC peer keep-alive receive is successful
Explanation Peer keep-alive receive successful
Recommended Action No action is required.
Error Message VPC-5-PEER_KEEP_ALIVE_SEND_INT_LATEST: In domain [dec], VPC peer-keepalive sent on interface [chars]
Explanation VPC peer-keepalive send interface changed
Recommended Action No action is required.
Error Message VPC-5-PEER_KEEP_ALIVE_SEND_SUCCESS: In domain [dec], vPC peer keep-alive send is successful
Explanation Peer keep-alive send successful
Recommended Action No action is required.
Error Message VPC-5-PEER_KEEP_ALIVE_STATUS: In domain [dec], peer keep-alive status changed to [chars]
Explanation Peer keep-alive (oob) status is changed to Recommended Action Peer-not-alive
Error Message VPC-5-ROLE_PRIORITY_CFGD: In domain [dec], vPC role priority changed to [dec]
Explanation Role priority configured
Recommended Action No action is required.
Error Message VPC-5-SYSTEM_MAC_CFGD: In domain [dec], vPC system-mac changed to [chars]
Explanation System mac configured
Recommended Action No action is required.
Error Message VPC-5-SYSTEM_PRIO_CFGD: In domain [dec], vPC system priority changed to [dec]
Explanation System priority changed
Recommended Action No action is required.
Error Message VPC-5-VPCM_DISABLED: vPC Manager disabled
Explanation VPCM Service Disabled
Recommended Action No action is required.
Error Message VPC-5-VPCM_ENABLED: vPC Manager enabled
Explanation VPCM Service Enabled
Recommended Action No action is required.
Error Message VPC-5-VPC_DELAY_SVI_BUP_TIMER_START: vPC restore, delay interface-vlan bringup timer started
Explanation VPC delay interface-vlan restore timer start
Recommended Action No action is required.
Error Message VPC-5-VPC_DOWN: vPC [dec] is down ([chars])
Explanation VPC is down (reason)
Recommended Action No action is required.
Error Message VPC-5-VPC_OPERATIONAL_L3_ROUTING: VPC operational layer3 peer-router is [chars]
Explanation VPC operational layer3 peer-router enabled or disabled
Recommended Action No action is required.
Error Message VPC-5-VPC_PEER_LINK_UP: vPC Peer-link is up
Explanation VPC Peer-link is up
Recommended Action No action is required.
Error Message VPC-5-VPC_RESTORE_TIMER_EXPIRED: vPC restore timer expired, reinitiating vPCs
Explanation VPC restore timer expired
Recommended Action No action is required.
Error Message VPC-5-VPC_RESTORE_TIMER_START: vPC restore timer started to reinit vPCs
Explanation VPC restore timer start
Recommended Action No action is required.
Error Message VPC-5-VPC_ROLE_PREMPT: In domain [dec], vPC role pre-emption triggered
Explanation VPC preemption triggered
Recommended Action No action is required.
Error Message VPC-5-VPC_SCALE_LIMIT: No port-channel limit configuration is [chars]
Explanation No port-channel limit configuration is changed
Recommended Action No action is required.
Error Message VPC-5-VPC_UP: vPC [dec] is up
Explanation MCEC is UP
Recommended Action No action is required.
Error Message VPC-6-ADD_SRC_INDX_ADD_FAILED: Adding src index [hex] to VDC failed
Explanation Add src index failed
Recommended Action No action is required.
Error Message VPC-6-CFS_APP_SEQ_PL_UP_SENT: Sent CFS sync trigger on peer-link coming up to SAP [dec].
Explanation Sent trigger to SAP to begin sync
Recommended Action No action is required.
Error Message VPC-6-DELETE_SRC_INDX_ADD_FAILED: Deleting src index [hex] to VDC failed
Explanation Delete src index failed
Recommended Action No action is required.
Error Message VPC-6-PEER_LOCK_FAILED: Locking failed on peer switch - Aborting upgrade!!
Explanation Locking failed on peer switch
Recommended Action No action is required.
Error Message VPC-6-PEER_VPC_CFGD_VLANS_CHANGED: Peer vPC [dec] configured vlans changed
Explanation Remote MCEC configured vlans changed
Recommended Action No action is required.
Error Message VPC-6-PEER_VPC_CFGD: peer vPC [dec] is configured
Explanation VPC is configured
Recommended Action No action is required.
Error Message VPC-6-PEER_VPC_DOWN: Peer vPC [dec] is down ([chars])
Explanation Peer vPC is down
Recommended Action No action is required.
Error Message VPC-6-PEER_VPC_UP: Peer vPC [dec] is up
Explanation Peer vPC is up
Recommended Action No action is required.
Error Message VPC-6-STATS_CLEARED: vPC Statistics Cleared
Explanation VPC statistics cleared
Recommended Action No action is required.
Error Message VPC-6-TRACK_OBJ_CONFIGURED: In domain [dec], track object configured [dec]
Explanation VPC track object configured
Recommended Action No action is required.
Error Message VPC-6-TRACK_OBJ_DELETED: In domain [dec], track object deleted
Explanation VPC track object deconfigured
Recommended Action No action is required.
Error Message VPC-6-TYPE1_PARAM_CHANGED: TYPE-1 parameters changed: [chars]
Explanation Type-1 Parameters Changed
Recommended Action No action is required.
Error Message VPC-6-VPCM_INTERNAL_INFO: [chars]
Explanation VPCM got an internal info [chars]
Recommended Action No action is required.
Error Message VPC-6-VPC_ALLOWED_VLAN_CHANGED: vPC [dec] operational vlans changed
Explanation Operational vlans changed on vPC
Recommended Action No action is required.
Error Message VPC-6-VPC_CFGD: vPC [dec] is configured
Explanation VPC is configured
Recommended Action No action is required.
Error Message VPC-6-VPC_CONSISTENCY_CHECK_BYPASS: Bypassing consistency check for vPC: [dec]
Explanation Bypassing consistency check for vpcs
Recommended Action No action is required.
Error Message VPC-6-VPC_CONSISTENCY_NEW_VLAN_PASS: Global Consistency check for vPC passed for new vlans
Explanation Global Consistency check for vPC passed for new vlans
Recommended Action No action is required.
Error Message VPC-6-VPC_DOMAIN_ID_CFGD: vPC domain-id configured to [dec]
Explanation VPC domain-id configured
Recommended Action No action is required.
Error Message VPC-6-VPC_ES_EGRESS_DF_STATE_CHANGED: Egress designated forwarder state changed from [chars] to [chars] for vPC [dec].
Explanation DF state changed for some vPC.
Recommended Action No action is required.
Error Message VPC-6-VPC_ES_ID_CFGD: Fabricpath switch ID [dec] configured
Explanation Fabricpath switch ID configured
Recommended Action No action is required.
Error Message VPC-6-VPC_ES_ID_REMOVED: Fabricpath switch ID [dec] removed
Explanation Fabricpath switch ID removed
Recommended Action No action is required.
Error Message VPC-6-VPC_PEER_LINK_CFGD: vPC peer-link is configured
Explanation VPC Peer-link is configured
Recommended Action No action is required.
Error Message VPC-6-VPC_PER_VLAN_CONSISTENCY_PASSED: Global Consistency check for vPC passed for all vlans
Explanation Global Consistency check for vPC passed for all vlans
Recommended Action No action is required.
This section contains the VSAN messages.
Error Message VSAN-6-REMOVED: Removed VSAN:[dec]
Explanation Removed VSAN with ID [dec].
Recommended Action No action is required.
This section contains the VTP messages.
Error Message VTP-0-EMERGENCY_MSG: [chars]
Explanation VTP Emergency Message
Recommended Action Capture show tech-support vtp
Error Message VTP-1-ALERT_MSG: [chars]
Explanation VTP Alert Message
Recommended Action Capture show tech-support vtp
Error Message VTP-2-CRITICAL_MSG: [chars]
Explanation VTP Critical Message
Recommended Action No action is required.
Error Message VTP-2-VTP_MODE_OFF_LONG_VLAN_NAME_EXIST: VTP Mode changed to off as long vlan name configuration is enabled
Explanation By default, VTP feature comes up in Server mode. long vlan name can only be enabled in VTP transparent/off mode As long vlan name is already enabled, VTP mode is changed to off.
Recommended Action No action is required.
Error Message VTP-2-VTP_MODE_OFF_PVLAN_EXIST: VTP Mode changed to off as Private VLAN configuration exists
Explanation By default, VTP feature comes up in Server mode. Private Vlans can only operate in VTP transparent/off mode As Private Vlan configuration already exist, VTP mode is changed to off.
Recommended Action No action is required.
Error Message VTP-2-VTP_MODE_OFF_RESERVED_VLAN_EXIST: VTP Mode changed to off as reserved vlan configuration exists
Explanation By default, VTP feature comes up in Server mode. reserved vlans can only operate in VTP transparent/off mode As Reserved Vlan configuration already exist, VTP mode is changed to off.
Recommended Action No action is required.
Error Message VTP-3-ERROR_MSG: [chars]
Explanation VTP Error Message
Recommended Action No action is required.
Error Message VTP-4-VLAN_CREATE_FAIL: Failed to create VLANs [chars]: [chars]
Explanation The VLANs specified in the error message could not be created. The VLAN manager called an VLAN database routine to create one or more VLANs, but the Vlan Manager failed the VLAN creation requests.
Recommended Action Collect show tech-support
Error Message VTP-4-VTP_BAD_VLAN_CONFIGURATION_FILE_VERSION: VLAN configuration file contained unknown file version: [dec]
Explanation The VLAN configuration file read by the VLAN manager contained an unrecognized file version number. (This may indicate an attempt to regress to an older version of the VLAN manager software.)
Recommended Action LOG_STD_ACTION
Error Message VTP-4-VTP_BAD_VLAN_CONFIGURATION_FILE: Vlan configuration file contained incorrect verification word: [hex]
Explanation The VLAN configuration file read by the VLAN manager did not begin with correct value which would indicate a valid VLAN configuration file. Thus, it has been rejected.
Recommended Action Collect show tech-support
Error Message VTP-4-VTP_BAD_VLAN_DOMAIN_NAME_LENGTH: VLAN configuration file contained incorrect domain name length: [dec]
Explanation The VLAN configuration file read by the VLAN manager did not contain a valid domain name length. Thus, it has been rejected.
Recommended Action Please provision VTP domain name again
Error Message VTP-4-VTP_BAD_VLAN_PASSWORD_LENGTH: VLAN configuration file contained incorrect VTP password length: [dec]
Explanation The VLAN configuration file read by the VLAN manager did not contain a valid VTP password length. Thus, it has been rejected.
Recommended Action Please provision VTP password again
Error Message VTP-4-VTP_INVALID_DATABASE_DATA: VTP received bad data
Explanation Invalid data was received by VTP process
Recommended Action Collect show tech-support
Error Message VTP-4-VTP_PROTOCOL_ERROR: VTP protocol code internal error: [chars]
Explanation VTP protocol code encountered an unexpected error will processing configuration request, packet, or timer expiration.
Recommended Action Collect show tech-support
Error Message VTP-4-WARN_MSG: [chars]
Explanation VTP Warning Message
Recommended Action No action is required.
Error Message VTP-5-NOTIF_MSG: [chars]
Explanation VTP Notification Message
Recommended Action No action is required.
Error Message VTP-6-INFO_MSG: [chars]
Explanation VTP Informational Message
Recommended Action No action is required.
Error Message VTP-6-VTP_DOMAIN_NAME_CHG: VTP domain name changed to [chars].
Explanation The VTP domain name was changed through configuration to the name specified in the message. A management domain is the naming scope of a VLAN name. Each VLAN has a name that is unique within the management domain.
Recommended Action No action is required.
Error Message VTP-6-VTP_MODE_CHANGE: VLAN manager changing device mode from [chars] to [chars].
Explanation Some switch devices must automatically change VTP device modes upon receipt of a VLAN configuration database containing more than a set number of VLANs, depending on the device. This message indicates that such a spontaneous conversion has occurred, what the previous mode was, and what the current mode is.
Recommended Action No action is required.
Error Message VTP-6-VTP_PRUNING_CHANGE: VTP Operational Pruning [chars].
Explanation VTP operational pruning changed. This can happen due to admin pruning change, VTP mode changes or VTP config propagation. 'show vtp status' output can be looked up to find the reason for this change.
Recommended Action Check 'show vtp status' output to find the reason for this change. No action is required.
Error Message VTP-7-DEBUG_MSG: [chars]
Explanation Association Manager Debug Message
Recommended Action No action is required.
This section contains the WWN messages.
Error Message WWN-2-GENERAL_ERROR: [chars]
Explanation The WWN Manager has encountered an critical error. The description of error is [str.].
Recommended Action No action is required.
Error Message WWN-2-PSS_ERROR: [chars]
Explanation The WWN Manager encountered error while operating on a persistent storage database.
Recommended Action No action is required.
Error Message WWN-3-STARTUP_COPY_TO_RUNNING_FAILED: [chars]
Explanation Could not snapshot Startup-Config PSS to Running-Config. The description of error is [str.].
Recommended Action No action is required.
Error Message WWN-5-VSAN_WWN_CHANGE: [chars]
Explanation VSAN-WWN created or deleted. The description of error is [str.].
Recommended Action No action is required.
Error Message WWN-6-SEC_MAC_UPDATED: MAC=[chars] Range=[dec]
Explanation The WWN Manager had updated the Secondary MAC address with MAC address [char] and range [dec]. This update was initiated from a management entity.
Recommended Action No action is required.
This section contains the XMLSA messages.
Error Message XMLSA-2-CANDIDATE_WRITE_FAIL: Netconf session id:[dec],candidate config has no space left
Explanation No space left in candidate configuration of the netconf session.
Recommended Action Please send the commit or discard request for the outstanding config.
Error Message XMLSA-2-VSH_ERR: XML sub agent vsh cmd error...: [chars]
Explanation XML sub agent vsh cmd error.
Recommended Action No action is required.
Error Message XMLSA-5-RPC_ERROR: Netconf session id:[dec], operation:[chars], status:FAILED, reason:[chars]
Explanation Netconf operation has failed.
Recommended Action No action is required.
Error Message XMLSA-5-RPC_OK: Netconf session id:[dec], operation:[chars], status:SUCCESS
Explanation Netconf operation is successful.
Recommended Action No action is required.
This section contains the ZONE messages.
Error Message ZONE-2-ZS_INIT_FAILED: [chars]
Explanation Zone Server initialization failed : [chars].
Recommended Action No action is required.
Error Message ZONE-2-ZS_MTS_OPER_FAILED: MTS [chars] operation failed : [chars]
Explanation Zone Server MTS [chars] operation failed : [chars].
Recommended Action No action is required.
Error Message ZONE-2-ZS_SHARED_DB_INIT_FAILED: [chars]
Explanation Zone Server shared DB initialization failed : [chars].
Recommended Action No action is required.
Error Message ZONE-3-ZS_MGMT_SEC_SDB_ERR: [chars] : [chars]
Explanation FC CT Mgmt Security shared db operation : [chars] : [chars].
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message ZONE-4-ZS_DB_WARNING: [chars]
Explanation Database operation warning: [chars].
Recommended Action No action is required.
Error Message ZONE-4-ZS_FC2_OPER_FAILED: FC2 [chars] operation failed : [chars]
Explanation Zone Server FC2 [chars] operation failed : [chars].
Recommended Action No action is required.
Error Message ZONE-6-ZS_FC2_OPER_INFO: FC2 [chars] operation failed : [chars]
Explanation Zone Server FC2 [chars] operation failed : [chars].
Recommended Action No action is required.
Error Message ZONE-6-ZS_INIT_WARNING: [chars]
Explanation Warning during Zone Server Initialization: [chars].
Recommended Action No action is required.
Error Message ZONE-6-ZS_UNKNOWN_LIC_FEATURE: [chars]
Explanation Zone Server received an event for an known licensing feature: [chars].
Recommended Action No action is required.