Configuring Interface Characteristics

Information About Configuring Interface Characteristics

Interface Types

This section describes the different types of interfaces supported by the device. The rest of the chapter describes configuration procedures for physical interface characteristics.

Port-Based VLANs

A VLAN is a switched network that is logically segmented by function, team, or application, without regard to the physical location of the users. Packets received on a port are forwarded only to ports that belong to the same VLAN as the receiving port. Network devices in different VLANs cannot communicate with one another without a Layer 3 device to route traffic between the VLANs.

VLAN partitions provide hard firewalls for traffic in the VLAN, and each VLAN has its own MAC address table. A VLAN comes into existence when a local port is configured to be associated with the VLAN, when the VLAN Trunking Protocol (VTP) learns of its existence from a neighbor on a trunk, or when a user creates a VLAN.

To configure VLANs, use the vlan vlan-id global configuration command to enter VLAN configuration mode. The VLAN configurations for normal-range VLANs (VLAN IDs 1 to 1005) are saved in the VLAN database. If VTP is version 1 or 2, to configure extended-range VLANs (VLAN IDs 1006 to 4094), you must first set VTP mode to transparent. Extended-range VLANs created in transparent mode are not added to the VLAN database but are saved in the device running configuration. With VTP version 3, you can create extended-range VLANs in client or server mode. These VLANs are saved in the VLAN database.

Add ports to a VLAN by using the switchport interface configuration commands:

  • Identify the interface.

  • For a trunk port, set trunk characteristics, and, if desired, define the VLANs to which it can belong.

  • For an access port, set and define the VLAN to which it belongs.

Switch Ports

Switch ports are Layer 2-only interfaces associated with a physical port. Switch ports belong to one or more VLANs. A switch port can be an access port or a trunk port. You can configure a port as an access port or trunk port or let the Dynamic Trunking Protocol (DTP) operate on a per-port basis to set the switchport mode by negotiating with the port on the other end of the link. switch ports are used for managing the physical interface and associated Layer 2 protocols and do not handle routing or bridging.

Configure switch ports by using the switchport interface configuration commands.

Access Ports

An access port belongs to and carries the traffic of only one VLAN (unless it is configured as a voice VLAN port). Traffic is received and sent in native formats with no VLAN tagging. Traffic arriving on an access port is assumed to belong to the VLAN assigned to the port. If an access port receives a tagged packet (Inter-Switch Link [ISL] or IEEE 802.1Q tagged), the packet is dropped, and the source address is not learned.

The types of access ports supported are:

  • Static access ports are manually assigned to a VLAN (or through a RADIUS server for use with IEEE 802.1x.

  • VLAN membership of dynamic access ports is learned through incoming packets. By default, a dynamic access port is not a member of any VLAN, and forwarding to and from the port is enabled only when the VLAN membership of the port is discovered. Dynamic access ports on the device are assigned to a VLAN by a VLAN Membership Policy Server (VMPS). The VMPS can be a Catalyst 6500 series switch; the device cannot be a VMPS server.

You can also configure an access port with an attached Cisco IP Phone to use one VLAN for voice traffic and another VLAN for data traffic from a device attached to the phone.

Trunk Ports

A trunk port carries the traffic of multiple VLANs and by default is a member of all VLANs in the VLAN database.

The device supports only IEEE 802.1Q trunk ports. An IEEE 802.1Q trunk port supports simultaneous tagged and untagged traffic. An IEEE 802.1Q trunk port is assigned a default port VLAN ID (PVID), and all untagged traffic travels on the port default PVID. All untagged traffic and tagged traffic with a NULL VLAN ID are assumed to belong to the port default PVID. A packet with a VLAN ID equal to the outgoing port default PVID is sent untagged. All other traffic is sent with a VLAN tag.

Although by default, a trunk port is a member of every VLAN known to the VTP, you can limit VLAN membership by configuring an allowed list of VLANs for each trunk port. The list of allowed VLANs does not affect any other port but the associated trunk port. By default, all possible VLANs (VLAN ID 1 to 4094) are in the allowed list. A trunk port can become a member of a VLAN only if VTP knows of the VLAN and if the VLAN is in the enabled state. If VTP learns of a new, enabled VLAN and the VLAN is in the allowed list for a trunk port, the trunk port automatically becomes a member of that VLAN and traffic is forwarded to and from the trunk port for that VLAN. If VTP learns of a new, enabled VLAN that is not in the allowed list for a trunk port, the port does not become a member of the VLAN, and no traffic for the VLAN is forwarded to or from the port.

Switch Virtual Interfaces

A switch virtual interface (SVI) represents a VLAN of switch ports as one interface to the routing or bridging function in the system. You can associate only one SVI with a VLAN. You configure an SVI for a VLAN only to route between VLANs or to provide IP host connectivity to the device. By default, an SVI is created for the default VLAN (VLAN 1) to permit remote device administration. Additional SVIs must be explicitly configured.


Note


You cannot delete interface VLAN 1.


SVIs provide IP host connectivity only to the system. SVIs are created the first time that you enter the vlan interface configuration command for a VLAN interface. The VLAN corresponds to the VLAN tag associated with data frames on an ISL or IEEE 802.1Q encapsulated trunk or the VLAN ID configured for an access port. Configure a VLAN interface for each VLAN for which you want to route traffic, and assign it an IP address.

You can also use the interface range command to configure existing VLAN SVIs within the range. The commands entered under the interface range command are applied to all existing VLAN SVIs within the range. You can enter the command interface range create vlan x - y to create all VLANs in the specified range that do not already exist. When the VLAN interface is created, interface range vlan id can be used to configure the VLAN interface.

When you create an SVI, it does not become active until it is associated with a physical port.

SVI Autostate Exclude

The line state of an SVI with multiple ports on a VLAN is in the up state when it meets these conditions:

  • The VLAN exists and is active in the VLAN database on the device

  • The VLAN interface exists and is not administratively down.

  • At least one Layer 2 (access or trunk) port exists, has a link in the up state on this VLAN, and is in the spanning-tree forwarding state on the VLAN.


Note


The protocol link state for VLAN interfaces come up when the first switchport belonging to the corresponding VLAN link comes up and is in STP forwarding state.


The default action, when a VLAN has multiple ports, is that the SVI goes down when all ports in the VLAN go down. You can use the SVI autostate exclude feature to configure a port so that it is not included in the SVI line-state up-or-down calculation. For example, if the only active port on the VLAN is a monitoring port, you might configure autostate exclude on that port so that the VLAN goes down when all other ports go down. When enabled on a port, autostate exclude applies to all VLANs that are enabled on that port.

The VLAN interface is brought up when one Layer 2 port in the VLAN has had time to converge (transition from STP listening-learning state to forwarding state). This prevents features such as routing protocols from using the VLAN interface as if it were fully operational and minimizes other problems.

EtherChannel Port Groups

EtherChannel port groups treat multiple switch ports as one switch port. These port groups act as a single logical port for high-bandwidth connections between devices or between devices and servers. An EtherChannel balances the traffic load across the links in the channel. If a link within the EtherChannel fails, traffic previously carried over the failed link changes to the remaining links. You can group multiple trunk ports into one logical trunk port or multiple access ports into one logical access port. Most protocols operate over either single ports or aggregated switch ports and do not recognize the physical ports within the port group. Exceptions are the DTP, the Cisco Discovery Protocol (CDP), and the Port Aggregation Protocol (PAgP), which operate only on physical ports.

When you configure an EtherChannel, you create a port-channel logical interface and assign an interface to the EtherChannel. For Layer 2 interfaces, use the channel-group interface configuration command to dynamically create the port-channel logical interface. This command binds the physical and logical ports together.


Note


Cisco Catalyst 2960-CX and 3560-CX support a maximum of six EtherChannel port groups.

Power over Ethernet Ports

A PoE-capable switch port automatically supplies power to one of these connected devices if the device senses that there is no power on the circuit:

  • a Cisco pre-standard powered device (such as a Cisco IP Phone or a Cisco Aironet Access Point)

  • an IEEE 802.3af-compliant powered device

A powered device can receive redundant power when it is connected to a PoE switch port and to an AC power source. The device does not receive redundant power when it is only connected to the PoE port.

Using the Switch USB Ports

USB Mini-Type B Console Port

The device has the following console ports:

  • USB mini-Type B console connection

  • RJ-45 console port

Console output appears on devices connected to both ports, but console input is active on only one port at a time. By default, the USB connector takes precedence over the RJ-45 connector.


Note


Windows PCs require a driver for the USB port. See the hardware installation guide for driver installation instructions.

Use the supplied USB Type A-to-USB mini-Type B cable to connect a PC or other device to the device. The connected device must include a terminal emulation application. When the device detects a valid USB connection to a powered-on device that supports host functionality (such as a PC), input from the RJ-45 console is immediately disabled, and input from the USB console is enabled. Removing the USB connection immediately reenables input from the RJ-45 console connection. An LED on the device shows which console connection is in use.

Console Port Change Logs

At software startup, a log shows whether the USB or the RJ-45 console is active. Every device always first displays the RJ-45 media type.

When the USB cable is removed or the PC de-activates the USB connection, the hardware automatically changes to the RJ-45 console interface:

You can configure the console type to always be RJ-45, and you can configure an inactivity timeout for the USB connector.

USB Type A Ports

The USB Type A ports provide access to external USB flash devices, also known as thumb drives or USB keys. The switch supports Cisco 64 MB, 256 MB, 512 MB, 1 GB, 4 GB, and 8 GB flash drives. You can use standard Cisco IOS command- line interface (CLI) commands to read, write, erase, and copy to or from the flash device. You can also configure the switch to boot from the USB flash drive.

Interface Connections

Devices within a single VLAN can communicate directly through any switch. Ports in different VLANs cannot exchange data without going through a routing device.

In the following configuration example, when Host A in VLAN 20 sends data to Host B in VLAN 30, the data must go from Host A to the device, to the router, back to the device, and then to Host B.

Figure 1. Connecting VLANs with the Switch

With a standard Layer 2 switch, ports in different VLANs have to exchange information through a router.


Note


The Catalyst 3560-CX and 2960-CX switches do not support stacking. Ignore all references to stacking throughout this book.


Interface Configuration Mode

The device supports these interface types:

  • Physical ports—device ports and routed ports

  • VLANs—switch virtual interfaces

  • Port channels—EtherChannel interfaces

You can also configure a range of interfaces.

To configure a physical interface (port), specify the interface type, module number, and device port number, and enter interface configuration mode.

  • Type—Gigabit Ethernet (gigabitethernet or gi) for 10/100/1000 Mb/s Ethernet ports, or small form-factor pluggable (SFP) module Gigabit Ethernet interfaces (gigabitethernet or gi).

  • Module number—The module or slot number on the switch (always 0).

  • Port number—The interface number on the switch. The 10/100/1000 port numbers always begin at 1, starting with the far left port when facing the front of the switch, for example, gigabitethernet1/0/1 or gigabitethernet1/0/8. For a switch with 10/100/1000 ports and SFP module ports, SFP module ports are numbered consecutively following the 10/100/1000 ports.

You can identify physical interfaces by physically checking the interface location on the switch. You can also use the show privileged EXEC commands to display information about a specific interface or all the interfaces on the switch. The remainder of this chapter primarily provides physical interface configuration procedures.

Default Ethernet Interface Configuration

This table shows the Ethernet interface default configuration, including some features that apply only to Layer 2 interfaces.

Table 1. Default Layer 2 Ethernet Interface Configuration

Feature

Default Setting

Operating mode

Layer 2 or switching mode (switchport command).

Allowed VLAN range

VLANs 1– 4094.

Default VLAN (for access ports)

VLAN 1.

Native VLAN (for IEEE 802.1Q trunks)

VLAN 1.

802.1p priority-tagged traffic

Drop all packets tagged with VLAN 0.

VLAN trunking

Switchport mode dynamic auto (supports DTP).

Port enable state

All ports are enabled.

Port description

None defined.

Speed

Autonegotiate. (Not supported on the 10-Gigabit interfaces.)

Duplex mode

Autonegotiate. (Not supported on the 10-Gigabit interfaces.)

Flow control

Flow control is set to receive: off . It is always off for sent packets.

EtherChannel (PAgP)

Disabled on all Ethernet ports.

Port blocking (unknown multicast and unknown unicast traffic)

Disabled (not blocked).

Broadcast, multicast, and unicast storm control

Disabled.

Protected port

Disabled.

Port security

Disabled.

Port Fast

Disabled.

Auto-MDIX

Enabled.

Note

 

The device might not support a pre-standard powered device—such as Cisco IP phones and access points that do not fully support IEEE 802.3af—if that powered device is connected to the device through a crossover cable. This is regardless of whether auto-MIDX is enabled on the switch port.

Power over Ethernet (PoE)

Enabled (auto).

Keepalive messages

Disabled on SFP module ports; enabled on all other ports.

Interface Speed and Duplex Mode

Ethernet interfaces on the switch operate at 10, 100, or 1000 Mb/s and in either full- or half-duplex mode. In full-duplex mode, two stations can send and receive traffic at the same time. Normally, 10-Mb/s ports operate in half-duplex mode, which means that stations can either receive or send traffic.

Switch modules include Gigabit Ethernet (10/100/1000-Mb/s) ports and small form-factor pluggable (SFP) module slots supporting SFP modules.

Speed and Duplex Configuration Guidelines

When configuring an interface speed and duplex mode, note these guidelines:

  • Do not disable Auto-Negotiation on PoE switches.

  • Gigabit Ethernet (10/100/1000-Mb/s) ports support all speed options and all duplex options (auto, half, and full). However, Gigabit Ethernet ports operating at 1000 Mb/s do not support half-duplex mode.

  • For SFP module ports, the speed and duplex CLI options change depending on the SFP module type:
    • The 1000BASE-x (where -x is -BX, -CWDM, -LX, -SX, and -ZX) SFP module ports support the nonegotiate keyword in the speed interface configuration command. Duplex options are not supported.

    • The 1000BASE-T SFP module ports support the same speed and duplex options as the 10/100/1000-Mb/s ports.

  • If both ends of the line support autonegotiation, we highly recommend the default setting of auto negotiation.

  • If one interface supports autonegotiation and the other end does not, configure duplex and speed on both interfaces; do not use the auto setting on the supported side.

  • When STP is enabled and a port is reconfigured, the device can take up to 30 seconds to check for loops. The port LED is amber while STP reconfigures.

  • As best practice, we suggest configuring the speed and duplex options on a link to auto or to fixed on both the ends. If one side of the link is configured to auto and the other side is configured to fixed, the link will not be up and this is expected.


Caution


Changing the interface speed and duplex mode configuration might shut down and re-enable the interface during the reconfiguration.


IEEE 802.3x Flow Control

Flow control enables connected Ethernet ports to control traffic rates during congestion by allowing congested nodes to pause link operation at the other end. If one port experiences congestion and cannot receive any more traffic, it notifies the other port by sending a pause frame to stop sending until the condition clears. Upon receipt of a pause frame, the sending device stops sending any data packets, which prevents any loss of data packets during the congestion period.


Note


The switch ports can receive, but not send, pause frames.


Use the flowcontrol interface configuration command to set the interface’s ability to receive pause frames to on , off , or desired .

When set to desired , an interface can operate with an attached device that is required to send flow-control packets or with an attached device that is not required to but can send flow-control packets.

These rules apply to flow control settings on the device:

  • receive on (or desired ): The port cannot send pause frames but can operate with an attached device that is required to or can send pause frames; the port can receive pause frames.

  • receive off : Flow control does not operate in either direction. In case of congestion, no indication is given to the link partner, and no pause frames are sent or received by either device.


Note


For details on the command settings and the resulting flow control resolution on local and remote ports, see the flowcontrol interface configuration command in the command reference for this release.


How to Configure Interface Characteristics

Configuring Interfaces

These general instructions apply to all interface configuration processes.

Procedure

  Command or Action Purpose

Step 1

enable

Example:


Switch> enable

Enables privileged EXEC mode.

  • Enter your password if prompted.

Step 2

configure terminal

Example:


Switch# configure terminal

Enters global configuration mode.

Step 3

interface

Example:


Switch(config)# interface gigabitethernet 1/0/1
Switch(config-if)# 

Identifies the interface type and the number of the connector.

Note

 

You do not need to add a space between the interface type and the interface number. For example, in the preceding line, you can specify either gigabitethernet 1/0/1 , gigabitethernet1/0/1 , gi 1/0/1 , or gi1/0/1 .

Step 4

Follow each interface command with the interface configuration commands that the interface requires.

Defines the protocols and applications that will run on the interface. The commands are collected and applied to the interface when you enter another interface command or enter end to return to privileged EXEC mode.

Step 5

interface range or interface range macro

(Optional) Configures a range of interfaces.

Note

 

Interfaces configured in a range must be the same type and must be configured with the same feature options.

Step 6

show interfaces

Displays a list of all interfaces on or configured for the switch. A report is provided for each interface that the device supports or for the specified interface.

Adding a Description for an Interface

SUMMARY STEPS

  1. enable
  2. configure terminal
  3. interface interface-id
  4. description string
  5. end
  6. show interfaces interface-id description
  7. copy running-config startup-config

DETAILED STEPS

  Command or Action Purpose

Step 1

enable

Example:


Switch> enable

Enables privileged EXEC mode.

  • Enter your password if prompted.

Step 2

configure terminal

Example:


Switch# configure terminal

Enters global configuration mode.

Step 3

interface interface-id

Example:


Switch(config)# interface gigabitethernet 1/0/2

Specifies the interface for which you are adding a description, and enter interface configuration mode.

Step 4

description string

Example:


Switch(config-if)# description Connects to Marketing

Adds a description (up to 240 characters) for an interface.

Step 5

end

Example:


Switch(config-if)# end

Returns to privileged EXEC mode.

Step 6

show interfaces interface-id description

Verifies your entry.

Step 7

copy running-config startup-config

Example:


Switch# copy running-config startup-config 

(Optional) Saves your entries in the configuration file.

Configuring a Range of Interfaces

To configure multiple interfaces with the same configuration parameters, use the interface range global configuration command. When you enter the interface-range configuration mode, all command parameters that you enter are attributed to all interfaces within that range until you exit this mode.

SUMMARY STEPS

  1. enable
  2. configure terminal
  3. interface range {port-range | macro macro_name}
  4. end
  5. show interfaces [interface-id]
  6. copy running-config startup-config

DETAILED STEPS

  Command or Action Purpose

Step 1

enable

Example:


Switch> enable

Enables privileged EXEC mode.

  • Enter your password if prompted.

Step 2

configure terminal

Example:


Switch# configure terminal

Enters global configuration mode.

Step 3

interface range {port-range | macro macro_name}

Example:


Switch(config)# interface range macro

Specifies the range of interfaces (VLANs or physical ports) to be configured, and enter interface-range configuration mode.

  • You can use the interface range command to configure up to five port ranges or a previously defined macro.

  • The macro variable is explained in the section on Configuring and Using Interface Range Macros.

  • In a comma-separated port-range , you must enter the interface type for each entry and enter spaces before and after the comma.

  • In a hyphen-separated port-range , you do not need to re-enter the interface type, but you must enter a space before the hyphen.

Note

 

Use the normal configuration commands to apply the configuration parameters to all interfaces in the range. Each command is executed as it is entered.

Step 4

end

Example:


Switch(config)# end

Returns to privileged EXEC mode.

Step 5

show interfaces [interface-id]

Example:


Switch# show interfaces

Verifies the configuration of the interfaces in the range.

Step 6

copy running-config startup-config

Example:


Switch# copy running-config startup-config 

(Optional) Saves your entries in the configuration file.

Configuring and Using Interface Range Macros

You can create an interface range macro to automatically select a range of interfaces for configuration. Before you can use the macro keyword in the interface range macro global configuration command string, you must use the define interface-range global configuration command to define the macro.

SUMMARY STEPS

  1. enable
  2. configure terminal
  3. define interface-range macro_name interface-range
  4. interface range macro macro_name
  5. end
  6. show running-config | include define
  7. copy running-config startup-config

DETAILED STEPS

  Command or Action Purpose

Step 1

enable

Example:


Switch> enable

Enables privileged EXEC mode.

  • Enter your password if prompted.

Step 2

configure terminal

Example:


Switch# configure terminal

Enters global configuration mode.

Step 3

define interface-range macro_name interface-range

Example:


Switch(config)# define interface-range enet_list gigabitethernet 1/0/1 - 2

Defines the interface-range macro, and save it in NVRAM.

  • The macro_name is a 32-character maximum character string.

  • A macro can contain up to five comma-separated interface ranges.

  • Each interface-range must consist of the same port type.

Note

 

Before you can use the macro keyword in the interface range macro global configuration command string, you must use the define interface-range global configuration command to define the macro.

Step 4

interface range macro macro_name

Example:


Switch(config)# interface range macro enet_list

Selects the interface range to be configured using the values saved in the interface-range macro called macro_name .

You can now use the normal configuration commands to apply the configuration to all interfaces in the defined macro.

Step 5

end

Example:


Switch(config)# end

Returns to privileged EXEC mode.

Step 6

show running-config | include define

Example:


Switch# show running-config | include define

Shows the defined interface range macro configuration.

Step 7

copy running-config startup-config

Example:


Switch# copy running-config startup-config 

(Optional) Saves your entries in the configuration file.

Configuring Ethernet Interfaces

Setting the Interface Speed and Duplex Parameters

SUMMARY STEPS

  1. enable
  2. configure terminal
  3. interface interface-id
  4. duplex {auto | full | half}
  5. end
  6. show interfaces interface-id
  7. copy running-config startup-config

DETAILED STEPS

  Command or Action Purpose

Step 1

enable

Example:

Switch> enable

Enables privileged EXEC mode.

  • Enter your password if prompted.

Step 2

configure terminal

Example:

Switch# configure terminal

Enters global configuration mode.

Step 3

interface interface-id

Example:

Switch(config)# interface gigabitethernet 1/0/3

Specifies the physical interface to be configured, and enter interface configuration mode.

Step 4

duplex {auto | full | half}

Example:

Switch(config-if)# duplex half

This command is not available on a 10-Gigabit Ethernet interface.

Enter the duplex parameter for the interface.

Enable half-duplex mode (for interfaces operating only at 10 or 100 Mb/s). You cannot configure half-duplex mode for interfaces operating at 1000 Mb/s.

You can configure the duplex setting when the speed is set to auto .

Step 5

end

Example:

Switch(config-if)# end

Returns to privileged EXEC mode.

Step 6

show interfaces interface-id

Example:

Switch# show interfaces gigabitethernet 1/0/3

Displays the interface speed and duplex mode configuration.

Step 7

copy running-config startup-config

Example:

Switch# copy running-config startup-config 

(Optional) Saves your entries in the configuration file.

Configuring IEEE 802.3x Flow Control

SUMMARY STEPS

  1. configure terminal
  2. interface interface-id
  3. flowcontrol {receive} {on | off | desired}
  4. end
  5. show interfaces interface-id
  6. copy running-config startup-config

DETAILED STEPS

  Command or Action Purpose

Step 1

configure terminal

Example:


Switch# configure terminal

Enters global configuration mode

Step 2

interface interface-id

Example:

Specifies the physical interface to be configured, and enter interface configuration mode.

Step 3

flowcontrol {receive} {on | off | desired}

Example:


Switch(config-if)# flowcontrol receive on

Configures the flow control mode for the port.

Step 4

end

Example:


Switch(config-if)# end

Returns to privileged EXEC mode.

Step 5

show interfaces interface-id

Example:

Verifies the interface flow control settings.

Step 6

copy running-config startup-config

Example:


Switch# copy running-config startup-config 

(Optional) Saves your entries in the configuration file.

Configuring SVI Autostate Exclude

SUMMARY STEPS

  1. enable
  2. configure terminal
  3. interface interface-id
  4. switchport autostate exclude
  5. end
  6. show running config interface interface-id
  7. copy running-config startup-config

DETAILED STEPS

  Command or Action Purpose

Step 1

enable

Example:


Switch> enable

Enables privileged EXEC mode.

  • Enter your password if prompted.

Step 2

configure terminal

Example:


Switch# configure terminal

Enters global configuration mode.

Step 3

interface interface-id

Example:


Switch(config)# interface gigabitethernet1/0/2

Specifies a Layer 2 interface (physical port or port channel), and enter interface configuration mode.

Step 4

switchport autostate exclude

Example:


Switch(config-if)# switchport autostate exclude

Excludes the access or trunk port when defining the status of an SVI line state (up or down)

Step 5

end

Example:


Switch(config-if)# end

Returns to privileged EXEC mode.

Step 6

show running config interface interface-id

(Optional) Shows the running configuration.

Verifies the configuration.

Step 7

copy running-config startup-config

Example:


Switch# copy running-config startup-config 

(Optional) Saves your entries in the configuration file.

Shutting Down and Restarting the Interface

Shutting down an interface disables all functions on the specified interface and marks the interface as unavailable on all monitoring command displays. This information is communicated to other network servers through all dynamic routing protocols. The interface is not mentioned in any routing updates.

SUMMARY STEPS

  1. enable
  2. configure terminal
  3. interface {vlan vlan-id} | { gigabitethernetinterface-id} | {port-channel port-channel-number}
  4. shutdown
  5. no shutdown
  6. end
  7. show running-config

DETAILED STEPS

  Command or Action Purpose

Step 1

enable

Example:


Switch> enable

Enables privileged EXEC mode.

  • Enter your password if prompted.

Step 2

configure terminal

Example:


Switch# configure terminal

Enters global configuration mode.

Step 3

interface {vlan vlan-id} | { gigabitethernetinterface-id} | {port-channel port-channel-number}

Example:


Switch(config)# interface gigabitethernet 1/0/2

Selects the interface to be configured.

Step 4

shutdown

Example:


Switch(config-if)# shutdown

Shuts down an interface.

Step 5

no shutdown

Example:


Switch(config-if)# no shutdown

Restarts an interface.

Step 6

end

Example:


Switch(config-if)# end

Returns to privileged EXEC mode.

Step 7

show running-config

Example:


Switch# show running-config 

Verifies your entries.

Configuring the Console Media Type

Follow these steps to set the console media type to RJ-45. If you configure the console as RJ-45, USB console operation is disabled, and input comes only through the RJ-45 connector.

SUMMARY STEPS

  1. enable
  2. configure terminal
  3. line console 0
  4. media-type rj45
  5. end
  6. copy running-config startup-config

DETAILED STEPS

  Command or Action Purpose

Step 1

enable

Example:


Switch> enable

Enables privileged EXEC mode.

  • Enter your password if prompted.

Step 2

configure terminal

Example:


Switch# configure terminal

Enters global configuration mode.

Step 3

line console 0

Example:


Switch(config)# line console 0

Configures the console and enters line configuration mode.

Step 4

media-type rj45

Example:


Switch(config-line)# media-type rj45

Configures the console media type to be only RJ-45 port. If you do not enter this command and both types are connected, the USB port is used by default.

Step 5

end

Example:


Switch(config)# end

Returns to privileged EXEC mode.

Step 6

copy running-config startup-config

Example:


Switch# copy running-config startup-config 

(Optional) Saves your entries in the configuration file.

Configuring the USB Inactivity Timeout

The configurable inactivity timeout reactivates the RJ-45 console port if the USB console port is activated but no input activity occurs on it for a specified time period. When the USB console port is deactivated due to a timeout, you can restore its operation by disconnecting and reconnecting the USB cable.

SUMMARY STEPS

  1. enable
  2. configure terminal
  3. line console 0
  4. usb-inactivity-timeout timeout-minutes
  5. copy running-config startup-config

DETAILED STEPS

  Command or Action Purpose

Step 1

enable

Example:


Switch> enable

Enables privileged EXEC mode.

  • Enter your password if prompted.

Step 2

configure terminal

Example:


Switch# configure terminal

Enters global configuration mode.

Step 3

line console 0

Example:


Switch(config)# line console 0

Configures the console and enters line configuration mode.

Step 4

usb-inactivity-timeout timeout-minutes

Example:


Switch(config-line)# usb-inactivity-timeout 30

Specify an inactivity timeout for the console port. The range is 1 to 240 minutes. The default is to have no timeout configured.

Step 5

copy running-config startup-config

Example:


Switch# copy running-config startup-config 

(Optional) Saves your entries in the configuration file.

Monitoring Interface Characteristics

Monitoring Interface Status

Commands entered at the privileged EXEC prompt display information about the interface, including the versions of the software and the hardware, the configuration, and statistics about the interfaces.

Table 2. Show Commands for Interfaces

Command

Purpose

show interfaces interface-number downshift modulemodule-number

Displays the downshift status details of the specified interfaces and modules.

show interfaces interface-id status [err-disabled]

Displays interface status or a list of interfaces in the error-disabled state.

show interfaces [interface-id] switchport

Displays administrative and operational status of switching (nonrouting) ports. You can use this command to find out if a port is in routing or in switching mode.

show interfaces [interface-id] description

Displays the description configured on an interface or all interfaces and the interface status.

show ip interface [interface-id]

Displays the usability status of all interfaces configured for IP routing or the specified interface.

show interface [interface-id] stats

Displays the input and output packets by the switching path for the interface.

show interfaces interface-id

(Optional) Displays speed and duplex on the interface.

show interfaces transceiver dom-supported-list

(Optional) Displays Digital Optical Monitoring (DOM) status on the connect SFP modules.

show interfaces transceiver properties

(Optional) Displays temperature, voltage, or amount of current on the interface.

show interfaces [interface-id] [{transceiver properties | detail}] module number]

Displays physical and operational status about an SFP module.

show running-config interface [interface-id]

Displays the running configuration in RAM for the interface.

show version

Displays the hardware configuration, software version, the names and sources of configuration files, and the boot images.

show controllers ethernet-controller interface-id phy

Displays the operational state of the auto-MDIX feature on the interface.

Clearing and Resetting Interfaces and Counters

Table 3. Clear Commands for Interfaces

Command

Purpose

clear counters [interface-id]

Clears interface counters.

clear interface interface-id

Resets the hardware logic on an interface.

clear line [number | console 0 | vty number]

Resets the hardware logic on an asynchronous serial line.


Note


The clear counters privileged EXEC command does not clear counters retrieved by using Simple Network Management Protocol (SNMP), but only those seen with the show interface privileged EXEC command.


Configuration Examples for Interface Characteristics

Configuring a Range of Interfaces: Examples

This example shows how to use the interface range global configuration command to set the speed to 100 Mb/s on ports 1 to 4 on switch 1:


Switch# configure terminal
Switch(config)# interface range gigabitethernet 1/0/1 - 4 
Switch(config-if-range)# speed 100

This example shows how to use a comma to add different interface type strings to the range to enable Gigabit Ethernet ports 1 to 3 and 10-Gigabit Ethernet ports 1 and 2 to receive flow-control pause frames:


Switch# configure terminal
Switch(config)# interface range gigabitethernet1/0/1 - 3 , tengigabitethernet1/1/1 - 2
Switch(config-if-range)# flowcontrol receive on

If you enter multiple configuration commands while you are in interface-range mode, each command is executed as it is entered. The commands are not batched and executed after you exit interface-range mode. If you exit interface-range configuration mode while the commands are being executed, some commands might not be executed on all interfaces in the range. Wait until the command prompt reappears before exiting interface-range configuration mode.

Configuring and Using Interface Range Macros: Examples

This example shows how to define an interface-range named enet_list to include ports 1 and 2 on switch 1 and to verify the macro configuration:


Switch# configure terminal
Switch(config)# define interface-range enet_list gigabitethernet 1/1/1 - 2
Switch(config)# end
Switch# show running-config | include define 
define interface-range enet_list gigabitethernet 1/1/1 - 2

This example shows how to create a multiple-interface macro named macro1:


Switch# configure terminal
Switch(config)# define interface-range macro1 gigabitethernet1/1/1 - 2, gigabitethernet1/1/5 - 7, tengigabitethernet1/1/1 -2
Switch(config)# end

This example shows how to enter interface-range configuration mode for the interface-range macro enet_list:


Switch# configure terminal
Switch(config)# interface range macro enet_list
Switch(config-if-range)# 

This example shows how to delete the interface-range macro enet_list and to verify that it was deleted.


Switch# configure terminal
Switch(config)# no define interface-range enet_list 
Switch(config)# end
Switch# show run | include define
Switch# 

Setting Interface Speed and Duplex Mode: Example

This example shows how to set the interface speed to 100 Mb/s and the duplex mode to half on a 10/100/1000 Mb/s port:


Switch# configure terminal
Switch(config)# interface gigabitethernet 1/0/3
Switch(config-if)# speed 10
Switch(config-if)# duplex half

This example shows how to set the interface speed to 100 Mb/s on a 10/100/1000 Mb/s port:


Switch# configure terminal
Switch(config)# interface gigabitethernet 1/0/2
Switch(config-if)# speed 100

Configuring the Console Media Type: Example

This example disables the USB console media type and enables the RJ-45 console media type.


Switch# configure terminal
Switch(config)# line console 0
Switch(config-line)# media-type rj45

This example reverses the previous configuration and immediately activates any USB console that is connected.


Switch# configure terminal
Switch(config)# line console 0
Switch(config-line)# no media-type rj45

Configuring the USB Inactivity Timeout: Example

This example configures the inactivity timeout to 30 minutes:


Switch# configure terminal
Switch(config)# line console 0
Switch(config-line)# usb-inactivity-timeout 30

To disable the configuration, use these commands:


Switch# configure terminal
Switch(config)# line console 0
Switch(config-line)# no usb-inactivity-timeout

If there is no (input) activity on a USB console port for the configured number of minutes, the inactivity timeout setting applies to the RJ-45 port, and a log shows this occurrence:


*Mar  1 00:47:25.625: %USB_CONSOLE-6-INACTIVITY_DISABLE: Console media-type USB disabled due to inactivity, media-type reverted to RJ45.

At this point, the only way to reactivate the USB console port is to disconnect and reconnect the cable.

When the USB cable on the switch has been disconnected and reconnected, a log similar to this appears:


*Mar  1 00:48:28.640: %USB_CONSOLE-6-MEDIA_USB: Console media-type is USB.