Configuring PoE

Finding Feature Information

Your software release may not support all the features documented in this module. For the latest caveats and feature information, see Bug Search Tool and the release notes for your platform and software release. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the feature information table at the end of this module.

Use Cisco Feature Navigator to find information about platform support and Cisco software image support. To access Cisco Feature Navigator, go to http:/​/​www.cisco.com/​go/​cfn. An account on Cisco.com is not required.

Information about PoE

Power over Ethernet Ports

A PoE-capable switch port automatically supplies power to one of these connected devices if the switch senses that there is no power on the circuit:

  • a Cisco pre-standard powered device (such as a Cisco IP Phone or a Cisco Aironet Access Point)

  • an IEEE 802.3af-compliant powered device

A powered device can receive redundant power when it is connected to a PoE switch port and to an AC power source. The device does not receive redundant power when it is only connected to the PoE port.

Supported Protocols and Standards

The switch uses these protocols and standards to support PoE:

  • CDP with power consumption—The powered device notifies the switch of the amount of power it is consuming. The switch does not reply to the power-consumption messages. The switch can only supply power to or remove power from the PoE port.

  • Cisco intelligent power management—The powered device and the switch negotiate through power-negotiation CDP messages for an agreed-upon power-consumption level. The negotiation allows a high-power Cisco powered device, which consumes more than 7 W, to operate at its highest power mode. The powered device first boots up in low-power mode, consumes less than 7 W, and negotiates to obtain enough power to operate in high-power mode. The device changes to high-power mode only when it receives confirmation from the switch.

    High-power devices can operate in low-power mode on switches that do not support power-negotiation CDP.

    Cisco intelligent power management is backward-compatible with CDP with power consumption; the switch responds according to the CDP message that it receives. CDP is not supported on third-party powered devices; therefore, the switch uses the IEEE classification to determine the power usage of the device.

  • IEEE 802.3af—The major features of this standard are powered-device discovery, power administration, disconnect detection, and optional powered-device power classification. For more information, see the standard.

  • The Cisco UPOE feature provides the capability to source up to 60 W of power (2 x 30 W) over both signal and spare pairs of the RJ-45 Ethernet cable by using the Layer-2 power negotiation protocols such as CDP or LLDP. An LLDP and CDP request of 30 W and higher in presence of the 4-wire Cisco Proprietary spare-pair power TLV can provide power on the spare pair.

Related Information
Cisco Universal Power Over Ethernet

Powered-Device Detection and Initial Power Allocation

The switch detects a Cisco pre-standard or an IEEE-compliant powered device when the PoE-capable port is in the no-shutdown state, PoE is enabled (the default), and the connected device is not being powered by an AC adaptor.

After device detection, the switch determines the device power requirements based on its type:

  • The initial power allocation is the maximum amount of power that a powered device requires. The switch initially allocates this amount of power when it detects and powers the powered device. As the switch receives CDP messages from the powered device and as the powered device negotiates power levels with the switch through CDP power-negotiation messages, the initial power allocation might be adjusted.

  • The switch classifies the detected IEEE device within a power consumption class. Based on the available power in the power budget, the switch determines if a port can be powered. Table 1 lists these levels.

Table 1 IEEE Power Classifications

Class

Maximum Power Level Required from the Switch

0 (class status unknown)

15.4 W

1

4 W

2

7 W

3

15.4 W

4

30 W (For IEEE 802.3at Type 2 powered devices)

The switch monitors and tracks requests for power and grants power only when it is available. The switch tracks its power budget (the amount of power available on the switch for PoE). Theswitch performs power-accounting calculations when a port is granted or denied power to keep the power budget up to date.

After power is applied to the port, the switch uses CDP to determine the CDP-specific power consumption requirement of the connected Cisco powered devices, which is the amount of power to allocate based on the CDP messages. The switch adjusts the power budget accordingly. This does not apply to third-party PoE devices. The switch processes a request and either grants or denies power. If the request is granted, the switch updates the power budget. If the request is denied, the switch ensures that power to the port is turned off, generates a syslog message, and updates the LEDs. Powered devices can also negotiate with the switch for more power.

With PoE+, powered devices use IEEE 802.3at and LLDP power with media dependent interface (MDI) type, length, and value descriptions (TLVs), Power-via-MDI TLVs, for negotiating power up to 30 W. Cisco pre-standard devices and Cisco IEEE powered devices can use CDP or the IEEE 802.3at power-via-MDI power negotiation mechanism to request power levels up to 30 W.


Note


The initial allocation for Class 0, Class 3, and Class 4 powered devices is 15.4 W. When a device starts up and uses CDP or LLDP to send a request for more than 15.4 W, it can be allocated up to the maximum of 30 W.



Note


The CDP-specific power consumption requirement is referred to as the actual power consumption requirement in the software configuration guides and command references.


If the switch detects a fault caused by an undervoltage, overvoltage, overtemperature, oscillator-fault, or short-circuit condition, it turns off power to the port, generates a syslog message, and updates the power budget and LEDs.

The PoE feature operates the same whether or not the switch is a stack member. The power budget is per switch and independent of any other switch in the stack. Election of a new active switch does not affect PoE operation. The active switch keeps track of the PoE status for all switches and ports in the stack and includes the status in output displays.

The stacking-capable switch also supports StackPower, which allows the power supplies to share the load across multiple systems in a stack when you connect the switches with power stack cables. You can manage the power supplies of up to four stack members as a one large power supply.

Power Management Modes

The switch supports these PoE modes:

  • auto—The switch automatically detects if the connected device requires power. If the switch discovers a powered device connected to the port and if the switch has enough power, it grants power, updates the power budget, turns on power to the port on a first-come, first-served basis, and updates the LEDs. For LED information, see the hardware installation guide.

    If the switch has enough power for all the powered devices, they all come up. If enough power is available for all powered devices connected to the switch, power is turned on to all devices. If there is not enough available PoE, or if a device is disconnected and reconnected while other devices are waiting for power, it cannot be determined which devices are granted or are denied power.

    If granting power would exceed the system power budget, the switch denies power, ensures that power to the port is turned off, generates a syslog message, and updates the LEDs. After power has been denied, the switch periodically rechecks the power budget and continues to attempt to grant the request for power.

    If a device being powered by the switch is then connected to wall power, the switch might continue to power the device. The switch might continue to report that it is still powering the device whether the device is being powered by the switch or receiving power from an AC power source.

    If a powered device is removed, the switch automatically detects the disconnect and removes power from the port. You can connect a nonpowered device without damaging it.

    You can specify the maximum wattage that is allowed on the port. If the IEEE class maximum wattage of the powered device is greater than the configured maximum value, the switch does not provide power to the port. If the switch powers a powered device, but the powered device later requests through CDP messages more than the configured maximum value, the switch removes power to the port. The power that was allocated to the powered device is reclaimed into the global power budget. If you do not specify a wattage, the switch delivers the maximum value. Use the auto setting on any PoE port. The auto mode is the default setting.

  • static—The switch pre-allocates power to the port (even when no powered device is connected) and guarantees that power will be available for the port. The switch allocates the port configured maximum wattage, and the amount is never adjusted through the IEEE class or by CDP messages from the powered device. Because power is pre-allocated, any powered device that uses less than or equal to the maximum wattage is guaranteed to be powered when it is connected to the static port. The port no longer participates in the first-come, first-served model.

    However, if the powered-device IEEE class is greater than the maximum wattage, the switch does not supply power to it. If the switch learns through CDP messages that the powered device is consuming more than the maximum wattage, the switch shuts down the powered device.

    If you do not specify a wattage, the switch pre-allocates the maximum value. The switch powers the port only if it discovers a powered device. Use the static setting on a high-priority interface.

  • never—The switch disables powered-device detection and never powers the PoE port even if an unpowered device is connected. Use this mode only when you want to make sure that power is never applied to a PoE-capable port, making the port a data-only port.

For most situations, the default configuration (auto mode) works well, providing plug-and-play operation. No further configuration is required. However, perform this task to configure a PoE port for a higher priority, to make it data only, or to specify a maximum wattage to disallow high-power powered devices on a port.

Stacking-capable switches also support StackPower, which allows switch power supplies to share the load across multiple systems in a stack by connecting up to four switches with power stack cables.

Power Monitoring and Power Policing

When policing of the real-time power consumption is enabled, the switch takes action when a powered device consumes more power than the maximum amount allocated, also referred to as the cutoff-power value.

When PoE is enabled, the switch senses the real-time power consumption of the powered device. The switch monitors the real-time power consumption of the connected powered device; this is called power monitoring or power sensing. The switch also polices the power usage with the power policing feature.

Power monitoring is backward-compatible with Cisco intelligent power management and CDP-based power consumption. It works with these features to ensure that the PoE port can supply power to the powered device.

The switch senses the real-time power consumption of the connected device as follows:

  1. The switch monitors the real-time power consumption on individual ports.

  2. The switch records the power consumption, including peak power usage. The switch reports the information through the CISCO-POWER-ETHERNET-EXT-MIB.

  3. If power policing is enabled, the switch polices power usage by comparing the real-time power consumption to the maximum power allocated to the device. The maximum power consumption is also referred to as the cutoff power on a PoE port.

    If the device uses more than the maximum power allocation on the port, the switch can either turn off power to the port, or the switch can generate a syslog message and update the LEDs (the port LED is now blinking amber) while still providing power to the device based on the switch configuration. By default, power-usage policing is disabled on all PoE ports.

    If error recovery from the PoE error-disabled state is enabled, the switch automatically takes the PoE port out of the error-disabled state after the specified amount of time.

    If error recovery is disabled, you can manually re-enable the PoE port by using the shutdown and no shutdown interface configuration commands.

  4. If policing is disabled, no action occurs when the powered device consumes more than the maximum power allocation on the PoE port, which could adversely affect the switch.

Power Consumption Values

You can configure the initial power allocation and the maximum power allocation on a port. However, these values are only the configured values that determine when the switch should turn on or turn off power on the PoE port. The maximum power allocation is not the same as the actual power consumption of the powered device. The actual cutoff power value that the switch uses for power policing is not equal to the configured power value.

When power policing is enabled, the switch polices the power usage at the switch port, which is greater than the power consumption of the device. When you are manually set the maximum power allocation, you must consider the power loss over the cable from the switch port to the powered device. The cutoff power is the sum of the rated power consumption of the powered device and the worst-case power loss over the cable.

We recommend that you enable power policing when PoE is enabled on your switch. For example, if policing is disabled and you set the cutoff-power value by using the power inline auto max 6300 interface configuration command, the configured maximum power allocation on the PoE port is 6.3 W (6300 mW). The switch provides power to the connected devices on the port if the device needs up to 6.3 W. If the CDP-power negotiated value or the IEEE classification value exceeds the configured cutoff value, the switch does not provide power to the connected device. After the switch turns on power on the PoE port, the switch does not police the real-time power consumption of the device, and the device can consume more power than the maximum allocated amount, which could adversely affect the switch and the devices connected to the other PoE ports.

Because a standalone switch supports internal power supplies, the total amount of power available for the powered devices varies depending on the power supply configuration.

  • If a power supply is removed and replaced by a new power supply with less power and the switch does not have enough power for the powered devices, the switch denies power to the PoE ports in auto mode in descending order of the port numbers. If the switch still does not have enough power, the switch then denies power to the PoE ports in static mode in descending order of the port numbers.

  • If the new power supply supports more power than the previous one and the switch now has more power available, the switch grants power to the PoE ports in static mode in ascending order of the port numbers. If it still has power available, the switch then grants power to the PoE ports in auto mode in ascending order of the port numbers.

The stacking-capable switch also supports StackPower, which allows power supplies to share the load across multiple systems in a stack by connecting the switches with power stack cables. You can collectively manage the power supplies of up to four stack members as a one large power supply.

Cisco Universal Power Over Ethernet

Cisco Universal Power Over Ethernet (Cisco UPOE) is a Cisco proprietary technology that extends the IEEE 802.at PoE standard to provide the capability to source up to 60 W of power over standard Ethernet cabling infrastructure (Class D or better) by using the spare pair of an RJ-45 cable (wires 4,5,7,8) with the signal pair (wires 1,2,3,6). Power on the spare pair is enabled when the switch port and end device mutually identify themselves as Cisco UPOE-capable using CDP or LLDP and the end device requests for power to be enabled on the spare pair. When the spare pair is powered, the end device can negotiate up to 60 W of power from the switch using CDP or LLDP.

If the end device is PoE-capable on both signal and spare pairs but does not support the CDP or LLDP extensions required for Cisco UPOE, a 4-pair forced mode configuration automatically enables power on both signal and spare pairs from the switch port.

How to Configure PoE

Configuring a Power Management Mode on a PoE Port


Note


When you make PoE configuration changes, the port being configured drops power. Depending on the new configuration, the state of the other PoE ports, and the state of the power budget, the port might not be powered up again. For example, port 1 is in the auto and on state, and you configure it for static mode. The switch removes power from port 1, detects the powered device, and repowers the port. If port 1 is in the auto and on state and you configure it with a maximum wattage of 10 W, the switch removes power from the port and then redetects the powered device. The switch repowers the port only if the powered device is a class 1, class 2, or a Cisco-only powered device.


SUMMARY STEPS

    1.    enable

    2.    configure terminal

    3.    interface interface-id

    4.    power inline {auto [max max-wattage] | never | static [max max-wattage]}

    5.    end

    6.    show power inline [interface-id | module switch-number]

    7.    copy running-config startup-config


DETAILED STEPS
     Command or ActionPurpose
    Step 1 enable


    Example:
    Switch> enable
    
    
     

    Enables privileged EXEC mode. Enter your password if prompted.

     

    Step 2configure terminal


    Example:
    Switch# configure terminal 
     

    Enters global configuration mode.

     
    Step 3interface interface-id


    Example:
    Switch(config)# interface gigabitethernet2/0/1 
     

    Specifies the physical port to be configured, and enters interface configuration mode.

     
    Step 4power inline {auto [max max-wattage] | never | static [max max-wattage]}


    Example:
    Switch(config-if)# power inline auto 
     

    Configures the PoE mode on the port. The keywords have these meanings:

    • auto—Enables powered-device detection. If enough power is available, automatically allocates power to the PoE port after device detection. This is the default setting.

    • max max-wattage—Limits the power allowed on the port. If no value is specified, the maximum is allowed.

    • max max-wattage—Limits the power allowed on the port. The range for Cisco UPOE ports is 4000 to 60000 mW. If no value is specified, the maximum is allowed.

    • never —Disables device detection, and disable power to the port.

    Note   

    If a port has a Cisco powered device connected to it, do not use the power inline never command to configure the port. A false link-up can occur, placing the port into the error-disabled state.

    • static—Enables powered-device detection. Pre-allocate (reserve) power for a port before the switch discovers the powered device. The switch reserves power for this port even when no device is connected and guarantees that power will be provided upon device detection.

    The switch allocates power to a port configured in static mode before it allocates power to a port configured in auto mode.

     
    Step 5end


    Example:
    Switch(config-if)# end
     

    Returns to privileged EXEC mode.

     
    Step 6show power inline [interface-id | module switch-number]


    Example:
    Switch# show power inline 
     

    Displays PoE status for a switch or a switch stack, for the specified interface, or for a specified stack member.

    The module switch-number keywords are supported only on stacking-capable switches.

     
    Step 7copy running-config startup-config


    Example:
    Switch# copy running-config startup-config 
    
    
     

    (Optional) Saves your entries in the configuration file.

     

    Enabling Power on Signal/Spare Pairs


    Note


    Do not enter this command if the end device cannot source inline power on the spare pair or if the end device supports the CDP or LLDP extensions for Cisco UPOE.


    SUMMARY STEPS

      1.    configure terminal

      2.    interface interface-id

      3.    power inline four-pair forced

      4.    end


    DETAILED STEPS
       Command or ActionPurpose
      Step 1configure terminal


      Example:
      Switch# configure terminal 
       

      Enters global configuration mode.

       
      Step 2interface interface-id


      Example:
      Switch(config)# interface gigabitethernet2/0/1 
       

      Specifies the physical port to be configured, and enters interface configuration mode.

       
      Step 3power inline four-pair forced


      Example:
      Switch(config-if)# power inline four-pair forced 
       

      Enables power on both signal and spare pairs from a switch port.

       
      Step 4end


      Example:
      Switch(config-if)# end
       

      Returns to privileged EXEC mode.

       

      Configuring Power Policing

      By default, the switch monitors the real-time power consumption of connected powered devices. You can configure the switch to police the power usage. By default, policing is disabled.

      SUMMARY STEPS

        1.    enable

        2.    configure terminal

        3.    interface interface-id

        4.    power inline police [action{log | errdisable}]

        5.    exit

        6.    Use one of the following:

        • errdisable detect cause inline-power
        • errdisable recovery cause inline-power
        • errdisable recovery interval interval

        7.    exit

        8.    Use one of the following:

        • show power inline police
        • show errdisable recovery

        9.    copy running-config startup-config


      DETAILED STEPS
         Command or ActionPurpose
        Step 1 enable


        Example:
        Switch> enable
        
        
         

        Enables privileged EXEC mode. Enter your password if prompted.

         

        Step 2configure terminal


        Example:
        Switch# configure terminal 
         

        Enters global configuration mode.

         
        Step 3interface interface-id


        Example:
        Switch(config)# interface gigabitethernet2/0/1 
         

        Specifies the physical port to be configured, and enter interface configuration mode.

         
        Step 4power inline police [action{log | errdisable}]


        Example:
        Switch(config-if)# power inline police 
         

        If the real-time power consumption exceeds the maximum power allocation on the port, configures the switch to take one of these actions:

        • power inline police—Shuts down the PoE port, turns off power to it, and puts it in the error-disabled state.

        Note   

        You can enable error detection for the PoE error-disabled cause by using the errdisable detect cause inline-power global configuration command. You can also enable the timer to recover from the PoE error-disabled state by using the errdisable recovery cause inline-power interval interval global configuration command.

        • power inline police action errdisable—Turns off power to the port if the real-time power consumption exceeds the maximum power allocation on the port.

        • power inline police action log—Generates a syslog message while still providing power to the port.

        If you do not enter the action log keywords, the default action shuts down the port and puts the port in the error-disabled state.

         
        Step 5exit


        Example:
        Switch(config-if)# exit
         

        Returns to global configuration mode.

         
        Step 6Use one of the following:
        • errdisable detect cause inline-power
        • errdisable recovery cause inline-power
        • errdisable recovery interval interval


        Example:
        Switch(config)# errdisable detect cause inline-power
        
        
        Switch(config)# errdisable recovery cause inline-power
        
        
        Switch(config)# errdisable recovery interval 100
        
        
         

        (Optional) Enables error recovery from the PoE error-disabled state, and configures the PoE recover mechanism variables.

        By default, the recovery interval is 300 seconds.

        For interval interval, specifies the time in seconds to recover from the error-disabled state. The range is 30 to 86400.

         
        Step 7exit


        Example:
        Switch(config)# exit
         

        Returns to privileged EXEC mode.

         
        Step 8Use one of the following:
        • show power inline police
        • show errdisable recovery


        Example:
        Switch# show power inline police
        
        
        Switch# show errdisable recovery
        
        
         

        Displays the power monitoring status, and verify the error recovery settings.

         
        Step 9copy running-config startup-config


        Example:
        Switch# copy running-config startup-config 
        
        
         

        (Optional) Saves your entries in the configuration file.

         

        Monitoring Power Status

        Table 2 Show Commands for Power Status

        Command

        Purpose

        show env power switch [switch-number]

        (Optional) Displays the status of the internal power supplies for each switch in the stack or for the specified switch.

        The range is 1 to 9, depending on the switch member numbers in the stack. These keywords are available only on stacking-capable switches.

        show power inline [interface-id | module switch-number]

        Displays PoE status for a switch or switch stack, for an interface, or for a specific switch in the stack.

        show power inline police

        Displays the power policing data.

        Additional References

        Error Message Decoder

        Description Link

        To help you research and resolve system error messages in this release, use the Error Message Decoder tool.

        https:/​/​www.cisco.com/​cgi-bin/​Support/​Errordecoder/​index.cgi

        MIBs

        MIB MIBs Link

        All supported MIBs for this release.

        To locate and download MIBs for selected platforms, Cisco IOS releases, and feature sets, use Cisco MIB Locator found at the following URL:

        http:/​/​www.cisco.com/​go/​mibs

        Technical Assistance

        Description Link

        The Cisco Support website provides extensive online resources, including documentation and tools for troubleshooting and resolving technical issues with Cisco products and technologies.

        To receive security and technical information about your products, you can subscribe to various services, such as the Product Alert Tool (accessed from Field Notices), the Cisco Technical Services Newsletter, and Really Simple Syndication (RSS) Feeds.

        Access to most tools on the Cisco Support website requires a Cisco.com user ID and password.

        http:/​/​www.cisco.com/​support

        Feature Information for PoE

        Release

        Modification

        Cisco IOS XE 3.2SE

        This feature was introduced.

        Cisco IOS XE 3.3SE

        The four-pair forced keywords were added.