Technical Specifications

C9606R Switch Chassis Specifications

Table 1. Physical Specifications of the Chassis

Item

Specification

Dimensions (H x W x D)

13.95 X 17.4 X 16.1 inches (35.43 x 44.2 x 40.9 cms)

Rack units (RU1)

8 RU

Weight (Chassis with two AC power supplies and fan tray)

63.0 lb (31.31 kg)

1 The chassis height is measured in rack units (RU or just U), where 1 RU or 1 U equals 1.75 in (44.45 mm).
Table 2. Environmental Specifications of the Chassis

Item

Specification

Ambient temperature and altitude for normal operations2

  • 23° to 113°F (-5 to +45ºC), up to 6,000 feet (1800 m)

  • 23° to 104°F (-5 to +40ºC), up to 10,000 feet (3000 m)

Ambient temperature and altitude for short-term3 exceptional conditions

  • 23°F to 122°F (-5ºC to +50ºC), up to 6,000 feet (1800 m)

  • 23°F to 122°F (-5ºC to +45ºC), up to 10,000 feet (3000 m)

Nonoperating and storage temperature

-40° to 167°F (-40° to 75°C)

Thermal transition

Hot to cold—at a maximum rate of 86°F (30°C) per hour

Cold to hot—at maximum rate of 204.8°F (96°C) per hour

Humidity (RH), ambient (noncondensing)

Operating, nonoperating and storage —10 to 95 percent

Altitude (operating and nonoperating)

-60 to 3000m (-197 to 9843 feet)

Sound power level (LwAD)

LwAD—74.7 dBA

This is with four power supply modules installed and delivering 50 percent of rated output power; measured according to International Organization for Standardization (ISO) 7779 and declared according to ISO 9296.

Airflow

Chassis—Right to left (when facing the front of the chassis)

Power supply—Front to back (forward air flow)

Shock

Operating—5G 11ms (Half-sine)

Nonoperating and storage— 15G 11ms (Half-sine)

Sine Vibration

  • Operating— 0.15G (10Hz-500Hz)

  • Nonoperating and storage— 0.8G (10Hz-500Hz)

Random Vibration (Operating)

Spectral Break Point Frequencies

Acceleration Spectral Density

Slope

2.5 – 5 Hz

-

6 db /octave

5 – 100 Hz

0.1 [(m/s²)²]/Hz

(0.001 g²/Hz)

-

100 – 200 Hz

-

-24 db /octave

Random Vibration (Nonoperating and Storage)

Spectral Break Point Frequencies

Acceleration Spectral Density

Slope

2.5 – 5 Hz

-

6 db /octave

5 – 100 Hz

1.0 [(m/s²)²]/Hz*

(0.01 g²/Hz)

-

100 – 200 Hz

-

-24 db /octave

2 Minimum ambient temperature for cold startup is 0ºC
3 Short-term exceptional conditions are for no longer than a one-year period of—96 consecutive hours, or 360 hours total, or 15 occurrences.

Power Supply Specifications

2000W AC-Input Power Supply Specifications

The following table lists specifications for the 2000W AC input power supply:

Table 3. 2000W AC-Input Power Supply Specifications
Specification Description

AC-input type

Wide-ranging input with power factor correction.

Note

 
Power factor correction is a standard feature on AC-input power supplies. Power factor correction reduces the reactive component in the source AC current, allowing higher power factors and lower harmonic current components.

AC-input voltage

Low-line (115 VAC nominal)—90VAC (min) to 140VAC (max)

High-line (230 VAC nominal)—180VAC (min) to 264VAC (max)

AC-input current

10.5A at 115VAC (1050W output)

7.8A at 230 VAC (2000W output)

AC-input frequency

50/60Hz nominal (47 to 63Hz full range)

Branch circuit requirement

Each chassis power supply should have its own dedicated, fused-branch circuit:

  • North America—15 A.

  • International—Circuits sized to local and national codes.

  • All AC power supply inputs are fully isolated.

    • Source AC can be out of phase between multiple power supplies in the same chassis, which means that PS1 can be operating from phase A and PS2 can be operating from phase B.

    • For high-line operation, the power supply operates with the line conductor wired to a source AC phase, and the Neutral conductor wired either to a Neutral, single-phase power system, or to another source AC phase as long as the net input voltage is in the range of 180 to 264 VAC.

Power supply output

  • 100 to 120 VAC operation

    • 12V output — 1050W

  • 200 to 240 VAC operation

    • 12V output — 2000W

Output holdup time

20 ms minimum with 1200W output

kVA rating4

2250W maximum (total output power)

Heat dissipation (in British Thermal Units (BTU))

683 BTU per hour

Weight

2.65 lb (1.2 kg)

4 The kVA rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch

2000WAC Power Supply AC Power Cords

The following table lists the specifications for the AC power cords that are available for the 2000W AC-input power supply. The table also includes references to power cord illustrations.


Note


All 2000W power supply power cord:

  • Lengths range from 9.84 – 14 feet (3.0 – 4.293 meters); with most cord lengths between 13 and 14 feet (4.013 and 4.293 meters)

  • Have an IEC60320/C15 appliance connector at one end.

    Figure 1. IEC60320/C15 Appliance Connector



Table 4. 2000 W Power Supply AC Power Cords

Locale

Part Number

Cordset Rating

Length

AC Source Plug Type

Brazil

CAB-ACBZ-12A

125 VAC, 12 A

2.5 meter (m)

Figure 2. CAB-ACBZ-12A= (Brazil)


Japan

CAB-TA-JP

125 VAC, 12 A

2.5 m

Figure 3. CAB-TA-JP= (Japan)


North America

CAB-TA-NA

125 VAC, 12 A

2.5 m

Figure 4. CAB-TA-NA= (North America)


China

CAB-TA-CN

250 VAC, 10 A

2.5 m

Figure 5. CAB-TA-CN= (China)


Continental Europe

CAB-TA-EU

250 VAC, 10 A

2.5 m

Figure 6. CAB-TA-EU= (Continental Europe)


Denmark

CAB-TA-DN

250 VAC, 10 A

2.5 m

Figure 7. CAB-TA-DN= (Denmark)


Israel

CAB-TA-IS

250 VAC, 16 A

2.5 m

Figure 8. CAB-TA-IS= (Israel)


Italy

CAB-TA-IT

250 VAC, 10 A

2.5 m

Figure 9. CAB-TA-IT= (Italy)


Japan

CAB-C15-CBN-JP

250 VAC, 12 A

3.05 m

Figure 10. CAB-C15-CBN-JP=(Japan)


Japan

CAB-TA-250V-JP

250 VAC, 15 A

2.5 m

Figure 11. CAB-TA-250V-JP= (Japan)


North America

CAB-AC-2KW-CBL

250 VAC, 13 A

4.25 m

Figure 12. CAB-AC-2KW-CBL= (North America)


India

CAB-TA-IN

250 VAC, 10 A

2.5 m

Figure 13. CAB-TA-IN= (India)


Switzerland

CAB-TA-SW

250 VAC, 10 A

2.5 m

Figure 14. CAB-TA-SW= (Switzerland)


United Kingdom

CAB-TA-UK

250 VAC, 10 A

2.5 m

Figure 15. CAB-TA-UK= (United Kingdom)


All countries except Japan

CAB-C15-CBN

250 VAC, 13 A

1.22 m

Figure 16. CAB-C15-CBN=

2000W DC-Input Power Supply Specifications

The following table lists specifications for the 2000W DC input power supply:

Table 5. 2000W DC-Input Power Supply Specifications
Specification Description

DC-input voltage

-40 to -72VDC, with extended range to -75VDC

DC-input current

Maximum: 60A per DC input at -40VDC input

Power supply output capacity

For 12VDC output—2000W

Output holdup time

5ms with 1200W output

Temperature

  • Steady State Operating: -5°C to 45°C

  • Non-operating: -40°C to +70°C

Humidity

  • Operating: 5 to 90 percent, non-condensing

  • Non-operating: 5 to 95 percent, non-condensing

Altitude

  • Operating: -500 to 10,000 feet over allowable temperature range (-5 to +45°C) and full load, de-rating 1.4°C per 1000 feet above 6,000 feet

    Note

     

    The operating altitude in China is 6,561.6 ft. (2000 m) maximum

  • Non-operating: -1,000 to 50,000 feet over allowable temperature range

Heat dissipation (in British Thermal Units (BTU))

932 BTU per hour (maximum)

Weight

2.82 lb (1.28 kg)

2000W DC Power Supply DC Power Cords

All 2000W DC power supply cords:

  • Lengths range from 9.84 to 14 feet (3.0 to 4.293 meters); with most cord lengths between 13 and 14 feet (4.013 and 4.293 meters)

    Figure 17. 2000W DC Power Supply Cord

    1

    Appliance connector (C10-638974-000)

    5

    6 AWG ultra flex cable or equivalent (red in color)

    2

    Plug housing (C10-638978)

    6

    Label

    3

    Socket contact

    7

    2x shrink wrap

    4

    6 AWG ultra flex cable or equivalent (black in color)

    -

    -

  • Have an C10-638974-000 appliance connector at one end.

    Figure 18. C10-638974-000 Appliance Connector

3000W AC-Input Power Supply Specifications

The following table lists specifications for the 3000W AC input power supply:

Table 6. 3000W AC-Input Power Supply Specifications
Specification Description

AC-input type

Wide-ranging input with power factor correction.

Note

 
Power factor correction is a standard feature on AC-input power supplies. Power factor correction reduces the reactive component in the source AC current, allowing higher power factors and lower harmonic current components.

AC-input voltage

Low-line (115 VAC nominal)—90VAC (min) to 140VAC (max)

High-line (230 VAC nominal)—180VAC (min) to 264VAC (max)

AC-input current

17.6A at 100VAC (1500W output)

17.6A at 200 VAC (3000W output)

AC-input frequency

50/60Hz nominal (47 to 63Hz full range)

Branch circuit requirement

Each chassis power supply should have its own dedicated, fused-branch circuit:

  • North America—20 A.

  • International—Circuits sized to local and national codes.

  • All AC power supply inputs are fully isolated.

    • Source AC can be out of phase between multiple power supplies in the same chassis, which means that PS1 can be operating from phase A and PS2 can be operating from phase B.

    • For high-line operation, the power supply operates with the line conductor wired to a source AC phase, and the Neutral conductor wired either to a Neutral, single-phase power system, or to another source AC phase as long as the net input voltage is in the range of 180 to 264 VAC.

Power supply output

  • 90 to 140 VAC operation

    • 12V output—1500W

  • 180 to 264 VAC operation

    • 12V output—3000W

Output holdup time

20 ms minimum with 1800W output at high line input

kVA rating5

3000W maximum (total output power)

Heat dissipation (in British Thermal Units (BTU))

683 BTU per hour

Weight

2.98 lb (1.35 kg)

5 The kVA rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch

3000W AC Power Supply AC Power Cords

The following table lists the specifications for the AC power cords that are available for the 3000W AC-input power supply. The table also includes references to power cord illustrations.

Table 7. 3000 W Power Supply AC Power Cords

Locale

Part Number

Cordset Rating

Length

AC Source Plug Type

Australia

CAB-9K16A-AUS

250 VAC,16 A

4.26 m

Figure 19. CAB-9K16A-AUS= (Australia)

Continental Europe

CAB-9K16A-EU

250 VAC, 16 A

2.5 m

Figure 20. CAB-9K16A-EU= (Continental Europe)

China

CAB-9k16A-CH

250 VAC, 16 A

4.27 m

Figure 21. CAB-9k16A-CH= (China)

International

CAB-9K16A-INT

250 VAC, 16 A

4.14 m

Figure 22. CAB-9K16A-INT= (International)

North America and Japan

CAB-9K20A-NA

125 VAC, 20 A,

4.26 m
Figure 23. CAB-9K20A-NA= (North America and Japan)

Switzerland

CAB-9K16A-SW

250 VAC, 16 A

2.5 m

Figure 24. CAB-9K16A-SW= (Switzerland)

US and Japan

CAB-9K16A-US2

250 VAC, 16 A

4.26 m
Figure 25. CAB-9K16A-US2= (US/Japan)

International

CAB-I309-C19-INTL

250 VAC, 16 A

3.96 m

Figure 26. CAB-I309-C19-INTL= (International

Cabinet Jumper Power Cord

CAB-C19-CBN

250 VAC, 16 A

2.74 m

Figure 27. CAB-C19-CBN=(Cabinet Jumper Power Cord)

Chassis and Module Power and Heat Values

The following tables provide the power and heat dissipation data. Unless otherwise noted, the information in the tables is measured under fully loaded conditions (transceivers installed).


Note


DC output power is the output from the power supply (internal to the system). The AC-input power is the input from the outlet to the power supply. The percentage difference between the two values is the efficiency of the power supply.


Table 8. Power Requirements and Heat Dissipation - Fan Tray

PID

AC-Input Power in Watts

(Power Allocated)

DC-Output in Watts

(Power Requested)

Current @ 90V

Current @ 120V

Current @ 180V

Current @ 240V

Heat Diss. in BTU / hr.

C9606-FAN

500

450

5.6

4.2

2.8

2.1

1706

Table 9. Power Requirements and Heat Dissipation - Supervisor Module

PID

AC-Input Power in Watts

(Power Allocated)

DC-Output in Watts

(Power Requested)

Current @ 90V

Current @ 120V

Current @ 180V

Current @ 240V

Heat Diss. in BTU / hr.

C9600-SUP-1

862

775

9.6

7.2

4.8

3.6

2942

C9600X-SUP-2

732

660W

8.15

6.1

4.1

3.05

2498

Table 10. Power Requirements and Heat Dissipation— Line Cards

PID

AC-Input Power in Watts

(Power Allocated)

DC-Output in Watts

(Power Requested)

Current @ 90V

Current @ 120V

Current @ 180V

Current @ 240V

Heat Diss. in BTU / hr.

C9600-LC-48S

256

230

2.9

2.2

1.5

1.1

874

C9600-LC-48YL

256

230

2.9

2.2

1.5

1.1

874

C9600-LC-24C

223

200

2.5

1.9

1.3

1

761

C9600-LC-48TX

350

315

3.9

3

2

1.5

1195

C9600-LC-40YL4CD

466

420

5.2

3.9

2.6

1.95

1590

C9600X-LC-32CD

495

450

5.6

4.2

2.8

2.1

1689

C9600X-LC-56YL4C

495

450

5.6

4.2

2.8

2.1

1689

Weight Specifications

The total weight of a fully configured chassis will depend on the type of chassis, the number of modules, and power supplies installed. Use the corresponding weights in the tables below to arrive at the total chassis weight for your hardware configuration.

Weight Measurement for Chassis

PID (add = for spare)

Weight (Chassis without Fan Tray and Power Supply Units)

C9606R

55.90 lb (25.36 kg)

Weight Measurements for Supervisor Module

PID (add = for spare)

Weight

C9600-SUP-1

12.02 lb (5.45 kg)

C9600X-SUP-2

12.02 lb (5.45 kg)

Weight Measurements for Line Cards

PID (add = for spare)

Weight

C9600-LC-48S

7.83 lb (3.55 kg)

C9600-LC-48YL

7.83 lb (3.55 kg)

C9600-LC-24C

7.67 lb (3.48 kg)

C9600-LC-48TX

8.88 lb (4.03 kg)

C9600-LC-40YL4CD

8.27 lb (3.75 kg)

C9600X-LC-32CD

8.71 lb (3.95 kg)

C9600X-LC-56YL4C

9.14 lbs (4.15 kg)

Weight Measurements for Power Supply Modules

PID (add = for spare)

Weight

C9600-PWR-2KWAC

2.65 lb (1.2 kg)

C9600-PWR-2KWDC

2.82 lb (1.28 kg)

C9600-PWR-3KWAC

2.98 lb (1.35 kg)

Blank Covers

PID (add = for spare)

Weight

C9606-SLOT-BLANK

(Cisco Catalyst 9600 Series Blank for Chassis Module Slot)

2.87 lb (1.3 kg)

C9606-PWR-BLANK

(Cisco Catalyst 9600 Series Blank for Chassis Power Supply Slot)

0.18 lb (0.08 kg)