- Index
- Preface
- Overview
- Using the Command-Line Interface
- Assigning the Switch IP Address and Default Gateway
- Configuring Cisco IOS Configuration Engine
- Administering the Switch
- Configuring Switch Alarms
- Configuring SDM Templates
- Configuring Switch-Based Authentication
- Configuring IEEE 802.1x Port-Based Authentication
- Configuring Interface Characteristics
- Configuring Command Macros
- Configuring VLANs
- Configuring Private VLANs
- Configuring IEEE 802.1Q and Layer 2 Protocol Tunneling
- Configuring STP
- Configuring MSTP
- Configuring Optional Spanning-Tree Features
- Configuring Resilient Ethernet Protocol
- Configuring Flex Links and the MAC Address-Table Move Update Feature
- Configuring DHCP Features and IP Source Guard
- Configuring Dynamic ARP Inspection
- Configuring IGMP Snooping and MVR
- Configuring Port-Based Traffic Control
- Configuring CDP
- Configuring LLDP and LLDP-MED
- Configuring UDLD
- Configuring SPAN and RSPAN
- Configuring RMON
- Configuring System Message Logging
- Configuring SNMP
- Configuring Embedded Event Manager
- Configuring Network Security wit
- Configuring Control-Plane Security
- Configuring QoS
- Configuring EtherChannels and Link State Tracking
- Configuring IP Unicast Routing
- Configuring IPv6 Unicast Routing
- Configuring IPv6 MLD Snooping
- Configuring IPv6 ACLs
- Configuring HSRP
- Configuring Cisco IOS IP SLAs Operations
- Configuring Enhanced Object Tracking
- Configuring Ethernet OAM, CFM, and E-LMI
- Configuring IP Multicast Routing
- Configuring MSDP
- Troubleshooting
- Configuring Online Diagnostics
- Supported MIBs
- Working with the Cisco IOS File System, Configuration Files, and Software Images
- Unsupported Commands in Cisco IOS Release 12.2(55)SE
- Recovering from a Software Failure
- Recovering from a Lost or Forgotten Password
- Preventing Autonegotiation Mismatches
- SFP Module Security and Identification
- Monitoring SFP Module Status
- Monitoring Temperature
- Using Ping
Troubleshooting
This chapter describes how to identify and resolve software problems related to the Cisco IOS software on the Cisco ME 3400E switch.
You can use the command-line interface (CLI) to identify and solve problems.
Additional troubleshooting information related to hardware is provided in the hardware installation guide.
Note For complete syntax and usage information for the commands used in this chapter, see the command reference for this release and the Cisco IOS Command Summary, Release 12.2.
•Recovering from a Software Failure
•Recovering from a Lost or Forgotten Password
Note Recovery procedures require that you have physical access to the switch.
•Preventing Autonegotiation Mismatches
•SFP Module Security and Identification
•
•Using the show platform forward Command
•Using On-Board Failure Logging
Recovering from a Software Failure
Switch software can be corrupted during an upgrade, by downloading the wrong file to the switch, and by deleting the image file. In all of these cases, the switch does not pass the power-on self-test (POST), and there is no connectivity.
This procedure uses boot loader commands and TFTP to recover from a corrupted or wrong image file. The recovery procedure requires that you have physical access to the switch.
Step 1 From your PC, download the software image tar file (image_filename.tar) from Cisco.com.
The Cisco IOS image is stored as a bin file in a directory in the tar file. For information about locating the software image files on Cisco.com, see the release notes.
Step 2 Extract the bin file from the tar file.
•If you are using Windows, use a zip program that can read a tar file. Use the zip program to navigate to and extract the bin file.
•If you are using UNIX, follow these steps:
1. Display the contents of the tar file by using the tar -tvf <image_filename.tar> UNIX command.
switch% tar -tvf image_filename.tar
2. Locate the bin file, and extract it by using the tar -xvf <image_filename.tar> <image_filename.bin> UNIX command.
switch% tar -xvf image_filename.tar image_filename.bin
x image_filename/image_filename.bin, 3970586 bytes, 7756 tape blocks
3. Verify that the bin file was extracted by using the ls -l <image_filename.bin> UNIX command.
switch% ls -l image_filename.bin
-rw-r--r-- 1 boba 3970586 Apr 21 12:00 image_filename/image_filename.bin
Step 3 Connect your PC to the switch Ethernet management port.
Step 4 Unplug the switch power cord.
Step 5 Press the Mode button, and at the same time, reconnect the power cord to the switch.
You can release the Mode button a second or two after the LED above port 1 goes off. Several lines of information about the software appear with instructions:
The system has been interrupted prior to initializing the flash file system. The following commands will initialize the flash file system, and finish loading the operating system software#
flash_init
boot
Step 6 Initialize the flash file system:
switch:
flash_init
Step 7 Connect the switch to a TFTP server through the Ethernet management port.
Step 8 Start the file transfer by using TFTP.
a. Specify the IP address of the TFTP server:
switch:
set ip_addr ip_address/mask
b. Specify the default router:
switch:
set default_router ip_address
Step 9 Copy the software image from the TFTP server to the switch:
switch:
copy tftp://ip_address/filesystem:/source-file-url flash:image_filename.bin
Step 10 Boot up the newly downloaded Cisco IOS image.
switch: boot flash:image_filename.bin
Step 11 Use the archive download-sw privileged EXEC command to download the software image to the switch or to the switch stack.
Step 12 Use the reload privileged EXEC command to restart the switch and to verify that the new software image is operating properly.
Step 13 Delete the flash:image_filename.bin file from the switch.
Recovering from a Lost or Forgotten Password
The default configuration for the switch allows an end user to recover from a lost password by interrupting the boot process during power-on and by entering a new password.
Note On these switches, a system administrator can disable some of the functionality of password recovery by allowing an end user to reset a password only by agreeing to return to the default configuration. If you are an end user trying to reset a password when password recovery has been disabled, a status message shows this during the recovery process.
Disabling password recovery provides configuration file security by preventing unauthorized users from accessing the configuration file.
The Cisco ME switch boot loader uses break-key detection to stop the automatic boot sequence for the password recovery purpose.
Note The break key character is different for each operating system.
On a SUN work station running UNIX, Ctrl-C is the break key.
On a PC running Windows XP or 2000, Ctrl-Break is the break key.
Cisco TAC has tabulated break keys for most common operating systems and an alternative break key sequence for those terminal emulators that do not support the break keys. To see that list go to:
http://www.cisco.com/warp/public/701/61.html#how-to
These sections describes how to recover a forgotten or lost switch password:
•Procedure with Password Recovery Enabled
•Procedure with Password Recovery Disabled
You enable or disable password recovery by using the service password-recovery global configuration command.
Follow the steps in this procedure if you have forgotten or lost the switch password.
Step 1 Connect a terminal or PC with terminal-emulation software to the switch console port.
Step 2 Set the line speed on the emulation software to 9600 baud.
Step 3 Power off the switch.
Reconnect the power cord to the switch.
Step 4 After the switch performs POST, the switch begins the autoboot process. The boot loader prompts the user for a break key character during the boot-up sequence, as shown in this example:
***** The system will autoboot in 5 seconds *****
Send a break key to prevent autobooting.
You must enter the break key on the console terminal within 5 seconds of receiving the message that the system will autoboot. The System LED flashes green until the break key is accepted. After the break key is accepted, the System LED turns off until after the switch boots.
Several lines of information about the software appear with instructions, informing you if the password recovery procedure has been disabled or not.
•If you see a message that begins with this:
The system has been interrupted, or encountered an error during initializion of the flash filesystem. The following commands will initialize the flash filesystem, and finish loading the operating system software:
flash_init
load_helper
boot
proceed to the "Procedure with Password Recovery Enabled" section, and follow the steps.
•If you see a message that begins with this:
The password-recovery mechanism has been triggered, but is currently disabled.
proceed to the "Procedure with Password Recovery Disabled" section, and follow the steps.
Step 5 After recovering the password, reload the switch:
Switch>
reload
Proceed with reload? [confirm] y
Procedure with Password Recovery Enabled
If the password-recovery mechanism is enabled, this message appears:
The system has been interrupted, or encountered an error during initializion of the flash filesystem. The following commands will initialize the flash filesystem, and finish loading the operating system software:
flash_init
load_helper
boot
Step 1 Initialize the flash file system:
switch
: flash_init
Step 2 If you had set the console port speed to anything other than 9600, it has been reset to that particular speed. Change the emulation software line speed to match that of the switch console port.
Step 3 Load any helper files:
switch:
load_helper
Step 4 Display the contents of flash memory:
switch:
dir flash:
The switch file system appears:
Directory of flash:
13 drwx 192 Mar 01 1993 22:30:48 image-name-mz.122-50-EX
11 -rwx 5825 Mar 01 1993 22:31:59 config.text
18 -rwx 720 Mar 01 1993 02:21:30 vlan.dat
16128000 bytes total (10003456 bytes free)
Step 5 Rename the configuration file to config.text.old.
This file contains the password definition.
switch
:rename flash:config.text flash:config.text.old
Step 6 Boot the system:
switch
:boot
You are prompted to start the setup program. Enter N at the prompt:
Continue with the configuration dialog? [yes/no]:
N
Step 7 At the switch prompt, enter privileged EXEC mode:
Switch>
enable
Step 8 Rename the configuration file to its original name:
Switch#
rename flash:config.text.old flash:config.text
Step 9 Copy the configuration file into memory:
Switch#
copy flash:config.text system:running-config
Source filename [config.text]?
Destination filename [running-config]?
Press Return in response to the confirmation prompts.
The configuration file is now reloaded, and you can change the password.
Step 10 Enter global configuration mode:
Switch#
configure terminal
Step 11 Change the password:
Switch (config)#
enable secret password
The secret password can be from 1 to 25 alphanumeric characters, can start with a number, is case sensitive, and allows spaces but ignores leading spaces.
Step 12 Return to privileged EXEC mode:
Switch (config)#
exit
Switch#
Step 13 Write the running configuration to the startup configuration file:
Switch#
copy running-config startup-config
The new password is now in the startup configuration.
Note This procedure is likely to leave your switch virtual interface in a shutdown state. You can identify this interface by entering the show running-config privileged EXEC command. To re-enable the interface, enter the interface vlan vlan-id global configuration command, and specify the VLAN ID of the shutdown interface. With the switch in interface configuration mode, enter the no shutdown command.
Step 14 Reload the switch:
Switch#
reload
Procedure with Password Recovery Disabled
If the password-recovery mechanism is disabled, this message appears:
The password-recovery mechanism has been triggered, but
is currently disabled. Access to the boot loader prompt
through the password-recovery mechanism is disallowed at
this point. However, if you agree to let the system be
reset back to the default system configuration, access
to the boot loader prompt can still be allowed.
Would you like to reset the system back to the default configuration (y/n)?
Note Disabling password recovery provides configuration file security by preventing unauthorized users from accessing the configuration file.
•If you enter n (no), the normal boot process continues as if the break key had not been pressed; you cannot access the boot loader prompt, and you cannot enter a new password. You see the message:
Press Enter to continue........
•If you enter y (yes), the configuration file in flash memory and the VLAN database file are deleted. When the default configuration loads, you can reset the password.
Step 1 Elect to continue with password recovery and lose the existing configuration:
Would you like to reset the system back to the default configuration (y/n)? Y
Step 2 Load any helper files:
Switch:
load_helper
Step 3 Display the contents of flash memory:
switch:
dir flash:
The switch file system appears:
Directory of flash:
13 drwx 192 Mar 01 1993 22:30:48 image-name-mz.122-50-SE
16128000 bytes total (10003456 bytes free)
Step 4 Boot the system:
Switch:
boot
You are prompted to start the setup program. To continue with password recovery, enter N at the prompt:
Continue with the configuration dialog? [yes/no]:
N
Step 5 At the switch prompt, enter privileged EXEC mode:
Switch>
enable
Step 6 Enter global configuration mode:
Switch#
configure terminal
Step 7 Change the password:
Switch (config)#
enable secret password
The secret password can be from 1 to 25 alphanumeric characters, can start with a number, is case sensitive, and allows spaces but ignores leading spaces.
Step 8 Return to privileged EXEC mode:
Switch (config)#
exit
Switch#
Step 9 Write the running configuration to the startup configuration file:
Switch#
copy running-config startup-config
The new password is now in the startup configuration.
Note This procedure is likely to leave your switch virtual interface in a shutdown state. You can identify this interface by entering the show running-config privileged EXEC command. To re-enable the interface, enter the interface vlan vlan-id global configuration command, and specify the VLAN ID of the shutdown interface. With the switch in interface configuration mode, enter the no shutdown command.
Step 10 You must now reconfigure the switch. If the system administrator has the backup switch and VLAN configuration files available, you should use those.
Preventing Autonegotiation Mismatches
The IEEE 802.3ab autonegotiation protocol manages the switch settings for speed (10, 100, and 1000 Mbps, excluding SFP module ports) and duplex (half or full). There are situations when this protocol can incorrectly align these settings, reducing performance. A mismatch occurs under these circumstances:
•A manually set speed or duplex parameter is different from the manually set speed or duplex parameter on the connected port.
•A port is set to autonegotiate, and the connected port is set to full duplex with no autonegotiation.
To maximize switch performance and ensure a link, follow one of these guidelines when changing the settings for duplex and speed:
•Let both ports autonegotiate both speed and duplex.
•Manually set the speed and duplex parameters for the ports on both ends of the connection.
Note If a remote device does not autonegotiate, configure the duplex settings on the two ports to match. The speed parameter can adjust itself even if the connected port does not autonegotiate.
SFP Module Security and Identification
Cisco small form-factor pluggable (SFP) modules have a serial EEPROM that contains the module serial number, the vendor name and ID, a unique security code, and cyclic redundancy check (CRC). When an SFP module is inserted in the switch, the switch software reads the EEPROM to verify the serial number, vendor name and vendor ID, and recompute the security code and CRC. If the serial number, the vendor name or vendor ID, the security code, or CRC is invalid, the software generates a security error message and places the interface in an error-disabled state.
Note The security error message references the GBIC_SECURITY facility. The switch supports SFP modules and does not support GBIC modules. Although the error message text refers to GBIC interfaces and modules, the security messages actually refer to the SFP modules and module interfaces. For more information about error messages, see the system message guide for this release.
If you are using a non-Cisco SFP module, remove the SFP module from the switch, and replace it with a Cisco module. After inserting a Cisco SFP module, use the errdisable recovery cause gbic-invalid global configuration command to verify the port status, and enter a time interval for recovering from the error-disabled state. After the elapsed interval, the switch brings the interface out of the error-disabled state and retries the operation. For more information about the errdisable recovery command, see the command reference for this release.
If the module is identified as a Cisco SFP module, but the system is unable to read vendor-data information to verify its accuracy, an SFP module error message is generated. In this case, you should remove and re-insert the SFP module. If it continues to fail, the SFP module might be defective.
Monitoring SFP Module Status
You can check the physical or operational status of an SFP module by using the show interfaces transceiver privileged EXEC command. This command shows the operational status, such as the temperature and the current for an SFP module on a specific interface and the alarm status. You can also use the command to check the speed and the duplex settings on an SFP module. For more information, see the show interfaces transceiver command in the command reference for this release.
Monitoring Temperature
The Cisco ME switch monitors the temperature conditions. The switch also uses the temperature information to control the fans. The temperature value is the temperature in the switch (not the external temperature). Enter the show env temperature privileged EXEC command to see if the temperature is okay or faulty.
The show env all command displays the temperature value, state, and thresholds.
This is an example of the output from the show env temperature command:
Switch# show env temperature
TEMPERATURE is OK
This is an example of the output from the show env all command:
Switch# show env all
FAN PS 1 is OK
FAN PS 2 is OK
TEMPERATURE is OK
Temperature Value: 23 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 66 Degree Celsius
Red Threshold : 74 Degree Celsius
POWER SUPPLY 1 is DC OK
POWER SUPPLY 2 is DC OK
ALARM CONTACT 1 is not asserted
ALARM CONTACT 2 is not asserted
ALARM CONTACT 3 is not asserted
ALARM CONTACT 4 is not asserted
For more information, see the command reference for this release.
Using Ping
These sections contain this information:
Understanding Ping
The Cisco ME switch supports IP ping, which you can use to test connectivity to remote hosts. Ping sends an echo request packet to an address and waits for a reply.
The Cisco ME switch also provides the Control Plane Security feature, which by default drops ping response packets received on user network interfaces (UNIs) or enhanced network interfaces (ENIs). However, methods are available to ping successfully from the switch to a host connected to a UNI or ENI.
Control Plane Security does not drop ping response packets to or from network node interfaces (NNIs), and no special configuration is required to enable pings to or from hosts connected to NNIs.
Using Ping
Beginning in privileged EXEC mode, use the ping command to ping another device on the network from the switch:
Note Ping is not supported on a UNI or ENI configured as an IEEE 802.1Q tunnel port.
Ping is supported on NNIs on all software images.
It is important to note that the software images available for the switch provide different options for pinging a host connected to a UNI or ENI:
•Metro IP access image that supports IP routing
•Metro access image
The next sections apply to both access ports and trunk ports.
All Software Versions
For all software images for the Cisco ME switch, you can use a Layer 3 service policy to enable pings from the switch to a host connected to a UNI or ENI.
Note For a switch running the metro IP access image, IP routing is not enabled by default and does not have to be enabled to use a Layer 3 service policy.
This example is one possible configuration:
switch# configure terminal
switch(config)# access list 101 permit ip any any
switch(config)# class-map match-any ping-class
switch(config-cmap)# match access-group 101
switch(config-cmap)# exit
switch(config)# policy-map ping-policy
switch(config-pmap)# class ping-class
switch(config-pmap-c)# police 1000000
switch(config-pmap-c)# exit
switch(config-pmap)# exit
switch(config)# int fa0/1
switch(config-if)# service-policy input ping-policy
switch(config-if)# switchport access vlan 2
switch(config-if)# no shut
switch(config-if)# exit
switch(config)# int vlan 2
switch(config-if)# ip address 192.168.1.1 255.255.255.0
switch(config-if)# end
switch# ping 192.168.1.2
Metro IP Access Image
When your switch is running the metro IP access image, you can use any of these methods:
•Apply a Layer 3 service policy to a UNI or ENI.
•Enable IP routing globally and ping from a switch virtual interface (SVI).
•Enable IP routing and ping from a routed port.
For a sample configuration of how to add a Layer 3 service policy to a UNI or ENI, see the "All Software Versions" section.
For examples using IP routing and pinging from an SVI or a routed port, see the next sections.
IP Routing and SVI
IP routing is only supported when the switch is running the metro IP access image.
You can use this configuration to enable IP routing and enable pings from an SVI to a host connected to a UNI or ENI.
Switch# configure terminal
Switch(config)# ip routing
Switch(config)# int fa0/1
Switch(config-if)# switchport access vlan 2
Switch(config-if)# no shutdown
Switch(config-if)# int vlan 2
Switch(config-if)# ip address 192.168.1.1 255.255.255.0
Switch(config-if)# end
Switch# ping 192.168.1.2
With this configuration, a host with an IP address of 192.168.1.2 can be pinged from the switch.
IP Routing and Routed Port
You can use this configuration to enable IP routing, change a switchport to a routed port, and permit pings from the switch to a connected host:
switch# configure terminal
switch(config)# int fa0/1
switch(config-if)# no switchport
switch(config-if)# ip address 192.168.1.1 255.255.255.0
switch(config-if)# no shutdown
switch(config-if)# exit
switch(config)# ip routing
switch(config)# end
switch# ping 192.168.1.2
Ping Responses
This response is typical of a successful ping to a host:
Switch# ping 72.20.52.3
Type escape sequence to abort.
Sending 5, 100-byte ICMP Echoes to 172.20.52.3, timeout is 2 seconds:
!!!!!
Success rate is 100 percent (5/5), round-trip min/avg/max = 1/2/4 ms
Switch#
An unsuccessful ping results in this message:
Switch# ping 72.20.52.3
Type escape sequence to abort.
Sending 5, 100-byte ICMP Echoes to 172.20.52.3, timeout is 2 seconds:
. . . . .
Success rate is 0 percent (0/5)
Summary
Keep these guidelines in mind while pinging:
•IP routing is available only with the metro IP access image and is disabled by default.
•To ping a host in a different IP subnetwork from the switch, you must have IP routing configured to route between the subnets, and a static route to the destination might also be appropriate. If you need to enable or configure IP routing, see Chapter 36, "Configuring IP Unicast Routing."
•All software versions can use a Layer 3 service policy to permit pings to and from a host connected to a UNI or ENI. For more information about policy maps, see the "Input and Output Policies" section on page 34-4.
If your switch is running the metro IP access image, use one of these methods to ping a host connected to a UNI or ENI:
•Use a Layer 3 service policy to permit pings to and from a host connected to a UNI or ENI.
•Enable global IP routing and configure a port as a routed port by using the no switchport interface configuration command.
•Enable global IP routing, create an SVI, and assign an IP address to it. For more information about SVIs, see the "Switch Virtual Interfaces" section on page 10-5.
To end a ping session, simultaneously press and release the Ctrl, Shift, and 6 keys, and then press the X key.
Using Layer 2 Traceroute
•Understanding Layer 2 Traceroute
•Layer 2 Traceroute Usage Guidelines
Understanding Layer 2 Traceroute
The Layer 2 traceroute feature allows the switch to identify the physical path that a packet takes from a source device to a destination device. Layer 2 traceroute supports only unicast source and destination MAC addresses. It finds the path by using the MAC address tables of the switches in the path. When the switch detects a device in the path that does not support Layer 2 traceroute, the switch continues to send Layer 2 trace queries and lets them time out.
Note Layer 2 traceroute is available only on NNIs.
The switch can only identify the path from the source device to the destination device. It cannot identify the path that a packet takes from source host to the source device or from the destination device to the destination host.
Layer 2 Traceroute Usage Guidelines
•Cisco Discovery Protocol (CDP) must be enabled on all the devices in the network. For Layer 2 traceroute to function properly, do not disable CDP.
Note CDP is enabled by default on NNIs. You can enable CDP on ENIs, but UNIs do not support CDP.
For a list of switches that support Layer 2 traceroute, see the "Layer 2 Traceroute Usage Guidelines" section. If any devices in the physical path are transparent to CDP, the switch cannot identify the path through these devices. For more information about enabling CDP, see Chapter 24, "Configuring CDP."
•A switch is reachable from another switch when you can test connectivity by using the ping privileged EXEC command. All switches in the physical path must be reachable from each other.
•The maximum number of hops identified in the path is ten.
•You can enter the traceroute mac or the traceroute mac ip privileged EXEC command on a switch that is not in the physical path from the source device to the destination device. All switches in the path must be reachable from this switch.
•The traceroute mac command output shows the Layer 2 path only when the specified source and destination MAC addresses belong to the same VLAN. If you specify source and destination MAC addresses that belong to different VLANs, the Layer 2 path is not identified, and an error message appears.
•If you specify a multicast source or destination MAC address, the path is not identified, and an error message appears.
•If the source or destination MAC address belongs to multiple VLANs, you must specify the VLAN to which both the source and destination MAC addresses belong. If the VLAN is not specified, the path is not identified, and an error message appears.
•The traceroute mac ip command output shows the Layer 2 path when the specified source and destination IP addresses belong to the same subnet. When you specify the IP addresses, the switch uses the Address Resolution Protocol (ARP) to associate the IP addresses with the corresponding MAC addresses and the VLAN IDs.
–If an ARP entry exists for the specified IP address, the switch uses the associated MAC address and identifies the physical path.
–If an ARP entry does not exist, the switch sends an ARP query and tries to resolve the IP address. If the IP address is not resolved, the path is not identified, and an error message appears.
•When multiple devices are attached to one port through hubs (for example, multiple CDP neighbors are detected on a port), the Layer 2 traceroute feature is not supported. When more than one CDP neighbor is detected on a port, the Layer 2 path is not identified, and an error message appears.
•This feature is not supported in Token Ring VLANs.
Displaying the Physical Path
You can display the physical path that a packet takes from a source device to a destination device by using one of these privileged EXEC commands:
•tracetroute mac [interface interface-id] {source-mac-address} [interface interface-id] {destination-mac-address} [vlan vlan-id] [detail]
•tracetroute mac ip {source-ip-address | source-hostname}{destination-ip-address | destination-hostname} [detail]
Note Layer 2 traceroute is available only on NNIs.
For more information, see the command reference for this release.
Using IP Traceroute
Understanding IP Traceroute
You can use IP traceroute to identify the path that packets take through the network on a hop-by-hop basis. The command output displays all network layer (Layer 3) devices, such as routers, that the traffic passes through on the way to the destination.
Your switches can participate as the source or destination of the traceroute privileged EXEC command and might or might not appear as a hop in the traceroute command output. If the switch is the destination of the traceroute, it is displayed as the final destination in the output. Intermediate switches do not show up in the output if they are only bridging the packet from one port to another within the same VLAN. However, if the intermediate switch is a multilayer switch that is routing a particular packet, this switch shows up as a hop in the output.
The traceroute privileged EXEC command uses the Time To Live (TTL) field in the IP header to cause routers and servers to generate specific return messages. Traceroute starts by sending a User Datagram Protocol (UDP) datagram to the destination host with the TTL field set to 1. If a router finds a TTL value of 1 or 0, it drops the datagram and sends an Internet Control Message Protocol (ICMP) time-to-live-exceeded message to the sender. Traceroute finds the address of the first hop by examining the source address field of this message.
To identify the next hop, traceroute sends a UDP packet with a TTL value of 2. The first router decrements the TTL field by 1 and sends the datagram to the next router. The second router sees a TTL value of 1, discards the datagram, and returns the time-to-live-exceeded message to the source. This process continues until the TTL is incremented to a value large enough for the datagram to reach the destination host (or until the maximum TTL is reached).
To learn when a datagram reaches its destination, traceroute sets the UDP destination port number in the datagram to a very large value that the destination host is unlikely to be using. When a host receives a datagram destined to itself containing a destination port number that is unused locally, it sends an ICMP port-unreachable error to the source. Because all errors except port-unreachable errors come from intermediate hops, the receipt of a port-unreachable error means that this message was sent by the destination port.
Executing IP Traceroute
Beginning in privileged EXEC mode, follow this step to trace that the path packets take through the network:
|
|
---|---|
traceroute ip host |
Trace the path that packets take through the network. |
Note Though other protocol keywords are available with the traceroute privileged EXEC command, they are not supported in this release.
This example shows how to perform a traceroute to an IP host:
Switch# traceroute ip 171.9.15.10
Type escape sequence to abort.
Tracing the route to 171.69.115.10
1 172.2.52.1 0 msec 0 msec 4 msec
2 172.2.1.203 12 msec 8 msec 0 msec
3 171.9.16.6 4 msec 0 msec 0 msec
4 171.9.4.5 0 msec 4 msec 0 msec
5 171.9.121.34 0 msec 4 msec 4 msec
6 171.9.15.9 120 msec 132 msec 128 msec
7 171.9.15.10 132 msec 128 msec 128 msec
Switch#
The display shows the hop count, IP address of the router, and the round-trip time in milliseconds for each of the three probes that are sent.
To end a trace in progress, enter the escape sequence (Ctrl-^ X by default). Simultaneously press and release the Ctrl, Shift, and 6 keys, and then press the X key.
Using TDR
•Running TDR and Displaying the Results
Understanding TDR
You can use the Time Domain Reflector (TDR) feature to diagnose and resolve cabling problems. When running TDR, a local device sends a signal through a cable and compares the reflected signal to the initial signal.
On the Cisco ME switch, TDR is supported only on the copper Ethernet 10/100 ports or on dual-purpose ports configured as 10/100/100 ports by using the RJ-45 connector.
TDR can detect these cabling problems:
•Open, broken, or cut twisted-pair wires—The wires are not connected to the wires from the remote device.
•Shorted twisted-pair wires—The wires are touching each other or the wires from the remote device. For example, a shorted twisted pair can occur if one wire of the twisted pair is soldered to the other wire.
If one of the twisted-pair wires is open, TDR can find the length at which the wire is open.
Use TDR to diagnose and resolve cabling problems in these situations:
•Replacing a switch
•Setting up a wiring closet
•Troubleshooting a connection between two devices when a link cannot be established or when it is not operating properly
Running TDR and Displaying the Results
To run TDR, enter the test cable-diagnostics tdr interface interface-id privileged EXEC command:
To display the results, enter the show cable-diagnostics tdr interface interface-id privileged EXEC command. For a description of the fields in the display, see the command reference for this release.
Note TDR is supported only on the copper Ethernet 10/100 ports or on dual-purpose ports configured as 10/100/100 ports by using the RJ-45 connector.
Using Debug Commands
•Enabling Debugging on a Specific Feature
•Enabling All-System Diagnostics
•Redirecting Debug and Error Message Output
Note For complete syntax and usage information for specific debug commands, see the command reference for this release.
Enabling Debugging on a Specific Feature
All debug commands are entered in privileged EXEC mode, and most debug commands take no arguments. For example, beginning in privileged EXEC mode, enter this command to enable the debugging for Switched Port Analyzer (SPAN):
Switch# debug span-session
The switch continues to generate output until you enter the no form of the command.
If you enable a debug command and no output appears, consider these possibilities:
•The switch might not be properly configured to generate the type of traffic that you want to monitor. Use the show running-config command to check its configuration.
•Even if the switch is properly configured, it might not generate the type of traffic that you want to monitor during the particular period that debugging is enabled. Depending on the feature you are debugging, you can use commands such as the TCP/IP ping command to generate network traffic.
To disable debugging of SPAN, enter this command in privileged EXEC mode:
Switch# no debug span-session
Alternately, in privileged EXEC mode, you can enter the undebug form of the command:
Switch# undebug span-session
To display the state of each debugging option, enter this command in privileged EXEC mode:
Switch# show debugging
Enabling All-System Diagnostics
Beginning in privileged EXEC mode, enter this command to enable all-system diagnostics:
Switch# debug all
The no debug all privileged EXEC command disables all diagnostic output. Using the no debug all command is a convenient way to ensure that you have not accidentally left any debug commands enabled.
Redirecting Debug and Error Message Output
By default, the network server sends the output from debug commands and system error messages to the console. If you use this default, you can use a virtual terminal connection to monitor debug output instead of connecting to the console port.
Possible destinations include the console, virtual terminals, internal buffer, and UNIX hosts running a syslog server. The syslog format is compatible with 4.3 Berkeley Standard Distribution (BSD) UNIX and its derivatives.
Note Be aware that the debugging destination you use affects system overhead. Logging messages to the console produces very high overhead, whereas logging messages to a virtual terminal produces less overhead. Logging messages to a syslog server produces even less, and logging to an internal buffer produces the least overhead of any method.
For more information about system message logging, see Chapter 29, "Configuring System Message Logging."
Using the show platform forward Command
The output from the show platform forward privileged EXEC command provides some useful information about the forwarding results if a packet entering an interface is sent through the system. Depending upon the parameters entered about the packet, the output provides lookup table results and port maps used to calculate forwarding destinations, bitmaps, and egress information.
Note For more syntax and usage information for the show platform forward command, see the switch command reference for this release.
Most of the information in the output from the command is useful mainly for technical support personnel, who have access to detailed information about the switch ASICs. However, packet forwarding information can also be helpful in troubleshooting.
This is an example of the output from the show platform forward command on Gigabit Ethernet port 1 in VLAN 5 when the packet entering that port is addressed to unknown MAC addresses. The packet should be flooded to all other ports in VLAN 5.
Switch# show platform forward gigabitethernet0/1 vlan 5 1.1.1 2.2.2 ip 13.1.1.1 13.2.2.2 udp 10 20
Global Port Number:24, Asic Number:5
Src Real Vlan Id:5, Mapped Vlan Id:5
Ingress:
Lookup Key-Used Index-Hit A-Data
InptACL 40_0D020202_0D010101-00_40000014_000A0000 01FFA 03000000
L2Local 80_00050002_00020002-00_00000000_00000000 00C71 0000002B
Station Descriptor:02340000, DestIndex:0239, RewriteIndex:F005
==========================================
Egress:Asic 2, switch 1
Output Packets:
------------------------------------------
Packet 1
Lookup Key-Used Index-Hit A-Data
OutptACL 50_0D020202_0D010101-00_40000014_000A0000 01FFE 03000000
Port Vlan SrcMac DstMac Cos Dscpv
Gi0/1 0005 0001.0001.0001 0002.0002.0002
------------------------------------------
Packet 2
Lookup Key-Used Index-Hit A-Data
OutptACL 50_0D020202_0D010101-00_40000014_000A0000 01FFE 03000000
Port Vlan SrcMac DstMac Cos Dscpv
Gi0/2 0005 0001.0001.0001 0002.0002.0002
------------------------------------------
<output truncated>
------------------------------------------
Packet 10
Lookup Key-Used Index-Hit A-Data
OutptACL 50_0D020202_0D010101-00_40000014_000A0000 01FFE 03000000
Packet dropped due to failed DEJA_VU Check on Gi0/2
This is an example of the output when the packet coming in on Gigabit Ethernet port 1 in VLAN 5 is sent to an address already learned on the VLAN on another port. It should be forwarded from the port on which the address was learned.
Switch# show platform forward gigabitethernet0/1 vlan 5 1.1.1 0009.43a8.0145 ip 13.1.1.1 13.2.2.2 udp 10 20
Global Port Number:24, Asic Number:5
Src Real Vlan Id:5, Mapped Vlan Id:5
Ingress:
Lookup Key-Used Index-Hit A-Data
InptACL 40_0D020202_0D010101-00_40000014_000A0000 01FFA 03000000
L2Local 80_00050009_43A80145-00_00000000_00000000 00086 02010197
Station Descriptor:F0050003, DestIndex:F005, RewriteIndex:0003
==========================================
Egress:Asic 3, switch 1
Output Packets:
------------------------------------------
Packet 1
Lookup Key-Used Index-Hit A-Data
OutptACL 50_0D020202_0D010101-00_40000014_000A0000 01FFE 03000000
Port Vlan SrcMac DstMac Cos Dscpv
Gi0/2 0005 0001.0001.0001 0009.43A8.0145
This is an example of the output when the packet coming in on Gigabit Ethernet port 1 in VLAN 5 has a destination MAC address set to the router MAC address in VLAN 5 and the destination IP address unknown. Because there is no default route set, the packet should be dropped.
Switch# show platform forward gigabitethernet0/1 vlan 5 1.1.1 03.e319.ee44 ip 13.1.1.1 13.2.2.2 udp 10 20
Global Port Number:24, Asic Number:5
Src Real Vlan Id:5, Mapped Vlan Id:5
Ingress:
Lookup Key-Used Index-Hit A-Data
InptACL 40_0D020202_0D010101-00_41000014_000A0000 01FFA 03000000
L3Local 00_00000000_00000000-90_00001400_0D020202 010F0 01880290
L3Scndr 12_0D020202_0D010101-00_40000014_000A0000 034E0 000C001D_00000000
Lookup Used:Secondary
Station Descriptor:02260000, DestIndex:0226, RewriteIndex:0000
This is an example of the output when the packet coming in on Gigabit Ethernet port 1 in VLAN 5 has a destination MAC address set to the router MAC address in VLAN 5 and the destination IP address set to an IP address that is in the IP routing table. It should be forwarded as specified in the routing table.
Switch# show platform forward gigabitethernet0/1 vlan 5 1.1.1 03.e319.ee44 ip 110.1.5.5 16.1.10.5
Global Port Number:24, Asic Number:5
Src Real Vlan Id:5, Mapped Vlan Id:5
Ingress:
Lookup Key-Used Index-Hit A-Data
InptACL 40_10010A05_0A010505-00_41000014_000A0000 01FFA 03000000
L3Local 00_00000000_00000000-90_00001400_10010A05 010F0 01880290
L3Scndr 12_10010A05_0A010505-00_40000014_000A0000 01D28 30090001_00000000
Lookup Used:Secondary
Station Descriptor:F0070007, DestIndex:F007, RewriteIndex:0007
==========================================
Egress:Asic 3, switch 1
Output Packets:
------------------------------------------
Packet 1
Lookup Key-Used Index-Hit A-Data
OutptACL 50_10010A05_0A010505-00_40000014_000A0000 01FFE 03000000
Port Vlan SrcMac DstMac Cos Dscpv
Gi0/2 0007 XXXX.XXXX.0246 0009.43A8.0147
Using the crashinfo File
The crashinfo file saves information that helps Cisco technical support representatives to debug problems that caused the Cisco IOS image to fail (crash). The switch writes the crash information to the console at the time of the failure, and the file is created the next time you boot the Cisco IOS image after the failure (instead of while the system is failing).
The information in the file includes the Cisco IOS image name and version that failed, a list of the processor registers, and a stack trace. You can provide this information to the Cisco technical support representative by using the show tech-support privileged EXEC command.
All crashinfo files are kept in this directory on the flash file system:
flash:/crashinfo/crashinfo_n where n is a sequence number.
Each new crashinfo file that is created uses a sequence number that is larger than any previously existing sequence number, so the file with the largest sequence number describes the most recent failure. Version numbers are used instead of a timestamp because the switches do not include a real-time clock. You cannot change the name of the file that the system will use when it creates the file. However, after the file is created, you can use the rename privileged EXEC command to rename it, but the contents of the renamed file will not be displayed by the show tech-support privileged EXEC command. You can delete crashinfo files by using the delete privileged EXEC command.
You can display the most recent crashinfo file (that is, the file with the highest sequence number at the end of its filename) by entering the show tech-support privileged EXEC command. You also can access the file by using any command that can copy or display files, such as the more or the copy privileged EXEC command.
Using On-Board Failure Logging
You can use the on-board-failure logging (OBFL) feature to collect information about the switch. The information includes uptime, temperature, and voltage information and helps Cisco technical support representatives to troubleshoot switch problems.
This section has this information:
Understanding OBFL
By default, OBFL is enabled. It collects information about the switch and small form-factor pluggable (SFP) modules. The switch stores this information in the flash memory:
•CLI commands—Record of the OBFL CLI commands that are entered on a switch
•Environmental data—Unique device identifier (UDI) information for a switch and for all the connected devices: the product identification (PID), the version identification (VID), and the serial number
•Message—Record of the hardware-related system messages generated by a switch
•Temperature—Temperature of a switch
•Uptime data—Time when a switch starts, the reason the switch restarts, and the length of time the switch has been running since it last restarted
•Voltage—System voltages of a switch
Note The Cisco ME 3400EG-2CS-A switch does not support voltage monitoring.
You should manually set the system clock, or configure it by using Network Time Protocol (NTP).
When the switch is running, you can retrieve the OBFL data by using the show logging onboard privileged EXEC commands. If the switch fails, contact your Cisco technical support representative to find out how to retrieve the data.
When an OBFL-enabled switch is restarted, there is a 10-minute delay before logging of new data begins.
Configuring OBFL
To enable OBFL, use the hw-module module logging onboard [message level level] global configuration command. Use the message level level parameter to specify the severity of the hardware-related messages that the switch generates and stores in the flash memory.
To copy the OBFL data to the local network or a specific file system, use the copy logging onboard module 1 destination privileged EXEC command.
Beginning in privileged EXEC mode, follow these steps to enable and configure OBFL. Note that OBLF is enabled by default; you need to enable it only if it has been disabled.
To disable OBFL, use the no hw-module module 1 logging onboard [message level] global configuration command.
To clear all the OBFL data in the flash memory except for the uptime and CLI command information, use the clear logging onboard privileged EXEC command.
For more information about the commands in this section, see the command reference for this release.
Displaying OBFL Information
To display the OBFL information, use one or more of the privileged EXEC commands in Table 46-2.
Note When an OBFL-enabled switch is restarted, there is a 10-minute delay before logging of new data begins.
These are examples of output from the show logging onboard commands:
Switch# show logging onboard clilog
--------------------------------------------------------------------------------
CLI LOGGING SUMMARY INFORMATION
--------------------------------------------------------------------------------
COUNT COMMAND
--------------------------------------------------------------------------------
1 hw-module module logging onboard
1 hw-module module logging onboard message level 7
4 show logging onboard
1 show logging onboard message
1 show logging onboard summary
--------------------------------------------------------------------------------
Switch# show logging onboard temp
--------------------------------------------------------------------------------
TEMPERATURE SUMMARY INFORMATION
--------------------------------------------------------------------------------
Number of sensors : 1
Sampling frequency : 5 minutes
Maximum time of storage : 720 minutes
--------------------------------------------------------------------------------
Sensor | ID | Maximum Temperature 0C
--------------------------------------------------------------------------------
System 1 41
--------------------------------------
Temp Sensor ID
0C 1
--------------------------------------
No historical data to display
--------------------------------------
Switch# show logging onboard uptime
--------------------------------------------------------------------------------
UPTIME SUMMARY INFORMATION
--------------------------------------------------------------------------------
First customer power on : 03/01/1993 00:06:06
Total uptime : 0 years 20 weeks 4 days 6 hours 20 minutes
Total downtime : 0 years 0 weeks 0 days 0 hours 0 minutes
Number of resets : 90
Number of slot changes : 0
Current reset reason : 0x0
Current reset timestamp : 03/01/1993 00:05:43
Current slot : 1
Current uptime : 0 years 0 weeks 2 days 6 hours 0 minutes
--------------------------------------------------------------------------------
Reset | |
Reason | Count |
--------------------------------------------------------------------------------
No historical data to display
--------------------------------------------------------------------------------
Switch# show logging onboard voltage
------------------------------------------------------------------------------------------
VOLTAGE SUMMARY INFORMATION
------------------------------------------------------------------------------------------
Number of sensors : 6
Sampling frequency : 1 minutes
Maximum time of storage : 720 minutes
------------------------------------------------------------------------------------------
Sensor | ID | Maximum Voltage
------------------------------------------------------------------------------------------
12.00V 0 12.567
1.25V 2 1.258
3.30V 3 3.305
2.50V 4 2.517
1.80V 5 1.825
1.50V 6 1.508
------------------------------------------------------------------------------------------
Nominal Range Sensor ID
------------------------------------------------------------------------------------------
No historical data to display
------------------------------------------------------------------------------------------
For more information about using the commands in Table 46-2 and for examples of OBFL data, see the command reference for this release.